These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

382 related articles for article (PubMed ID: 33314247)

  • 1. An error detection method for real-time EPID-based treatment delivery quality assurance.
    Alves VGL; Ahmed M; Aliotta E; Choi W; Siebers JV
    Med Phys; 2021 Feb; 48(2):569-578. PubMed ID: 33314247
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Swiss cheese error detection method for real-time EPID-based quality assurance and error prevention.
    Passarge M; Fix MK; Manser P; Stampanoni MF; Siebers JV
    Med Phys; 2017 Apr; 44(4):1212-1223. PubMed ID: 28134989
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detecting MLC modeling errors using radiomics-based machine learning in patient-specific QA with an EPID for intensity-modulated radiation therapy.
    Sakai M; Nakano H; Kawahara D; Tanabe S; Takizawa T; Narita A; Yamada T; Sakai H; Ueda M; Sasamoto R; Kaidu M; Aoyama H; Ishikawa H; Utsunomiya S
    Med Phys; 2021 Mar; 48(3):991-1002. PubMed ID: 33382467
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Toward real-time verification for MLC tracking treatments using time-resolved EPID imaging.
    Zwan BJ; Caillet V; Booth JT; Colvill E; Fuangrod T; O'Brien R; Briggs A; O'Connor DJ; Keall PJ; Greer PB
    Med Phys; 2021 Mar; 48(3):953-964. PubMed ID: 33354787
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging.
    Zwan BJ; Barnes MP; Hindmarsh J; Lim SB; Lovelock DM; Fuangrod T; O'Connor DJ; Keall PJ; Greer PB
    Med Phys; 2017 Aug; 44(8):3909-3922. PubMed ID: 28564208
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.
    Li T; Wu Q; Yang Y; Rodrigues A; Yin FF; Jackie Wu Q
    Med Phys; 2015 Jan; 42(1):381-90. PubMed ID: 25563278
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods.
    Defoor DL; Stathakis S; Roring JE; Kirby NA; Mavroidis P; Obeidat M; Papanikolaou N
    J Appl Clin Med Phys; 2017 Jul; 18(4):172-179. PubMed ID: 28585300
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A novel method for sub-arc VMAT dose delivery verification based on portal dosimetry with an EPID.
    Cools RAM; Dirkx MLP; Heijmen BJM
    Med Phys; 2017 Nov; 44(11):5556-5562. PubMed ID: 28815696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. EPID sensitivity to delivery errors for pre-treatment verification of lung SBRT VMAT plans.
    Alharthi T; Arumugam S; Vial P; Holloway L; Thwaites D
    Phys Med; 2019 Mar; 59():37-46. PubMed ID: 30928064
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A method to reconstruct and apply 3D primary fluence for treatment delivery verification.
    Liu S; Mazur TR; Li H; Curcuru A; Green OL; Sun B; Mutic S; Yang D
    J Appl Clin Med Phys; 2017 Jan; 18(1):128-138. PubMed ID: 28291913
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of pretreatment VMAT quality assurance with the integral quality monitor (IQM) and electronic portal imaging device (EPID).
    Ghafarian M; Price M; Morales-Paliza M
    J Appl Clin Med Phys; 2021 Mar; 22(3):166-175. PubMed ID: 33596336
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.
    Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S
    Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system.
    Karagoz G; Zorlu F; Yeginer M; Yildiz D; Ozyigit G
    J Appl Clin Med Phys; 2016 Mar; 17(2):14-23. PubMed ID: 27074451
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multi-institutional investigation into the robustness of intra-cranial multi-target stereotactic radiosurgery plans to delivery errors.
    May L; Hardcastle N; Hernandez V; Saez J; Rosenfeld A; Poder J
    Med Phys; 2024 Feb; 51(2):910-921. PubMed ID: 38141043
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An EPID-based system for gantry-resolved MLC quality assurance for VMAT.
    Zwan BJ; Barnes MP; Fuangord T; Stanton CJ; O'Connor DJ; Keall PJ; Greer PB
    J Appl Clin Med Phys; 2016 Sep; 17(5):348-365. PubMed ID: 27685132
    [TBL] [Abstract][Full Text] [Related]  

  • 16. IMRT QA and gamma comparisons: The impact of detector geometry, spatial sampling, and delivery technique on gamma comparison sensitivity.
    Steers JM; Fraass BA
    Med Phys; 2021 Sep; 48(9):5367-5381. PubMed ID: 34036596
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An integral quality monitoring system for real-time verification of intensity modulated radiation therapy.
    Islam MK; Norrlinger BD; Smale JR; Heaton RK; Galbraith D; Fan C; Jaffray DA
    Med Phys; 2009 Dec; 36(12):5420-8. PubMed ID: 20095254
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Error detection and classification in patient-specific IMRT QA with dual neural networks.
    Potter NJ; Mund K; Andreozzi JM; Li JG; Liu C; Yan G
    Med Phys; 2020 Oct; 47(10):4711-4720. PubMed ID: 33460182
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation.
    Hirashima H; Miyabe Y; Nakamura M; Mukumoto N; Mizowaki T; Hiraoka M
    J Appl Clin Med Phys; 2018 May; 19(3):234-242. PubMed ID: 29633542
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intrinsic detector sensitivity analysis as a tool to characterize ArcCHECK and EPID sensitivity to variations in delivery for lung SBRT VMAT plans.
    Alharthi T; Vial P; Holloway L; Thwaites D
    J Appl Clin Med Phys; 2021 Jun; 22(6):229-240. PubMed ID: 33949087
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.