5. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging. Zwan BJ; Barnes MP; Hindmarsh J; Lim SB; Lovelock DM; Fuangrod T; O'Connor DJ; Keall PJ; Greer PB Med Phys; 2017 Aug; 44(8):3909-3922. PubMed ID: 28564208 [TBL] [Abstract][Full Text] [Related]
6. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation. Li T; Wu Q; Yang Y; Rodrigues A; Yin FF; Jackie Wu Q Med Phys; 2015 Jan; 42(1):381-90. PubMed ID: 25563278 [TBL] [Abstract][Full Text] [Related]
7. Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods. Defoor DL; Stathakis S; Roring JE; Kirby NA; Mavroidis P; Obeidat M; Papanikolaou N J Appl Clin Med Phys; 2017 Jul; 18(4):172-179. PubMed ID: 28585300 [TBL] [Abstract][Full Text] [Related]
8. A novel method for sub-arc VMAT dose delivery verification based on portal dosimetry with an EPID. Cools RAM; Dirkx MLP; Heijmen BJM Med Phys; 2017 Nov; 44(11):5556-5562. PubMed ID: 28815696 [TBL] [Abstract][Full Text] [Related]
9. EPID sensitivity to delivery errors for pre-treatment verification of lung SBRT VMAT plans. Alharthi T; Arumugam S; Vial P; Holloway L; Thwaites D Phys Med; 2019 Mar; 59():37-46. PubMed ID: 30928064 [TBL] [Abstract][Full Text] [Related]
10. A method to reconstruct and apply 3D primary fluence for treatment delivery verification. Liu S; Mazur TR; Li H; Curcuru A; Green OL; Sun B; Mutic S; Yang D J Appl Clin Med Phys; 2017 Jan; 18(1):128-138. PubMed ID: 28291913 [TBL] [Abstract][Full Text] [Related]
11. Comparison of pretreatment VMAT quality assurance with the integral quality monitor (IQM) and electronic portal imaging device (EPID). Ghafarian M; Price M; Morales-Paliza M J Appl Clin Med Phys; 2021 Mar; 22(3):166-175. PubMed ID: 33596336 [TBL] [Abstract][Full Text] [Related]
12. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry. Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system. Karagoz G; Zorlu F; Yeginer M; Yildiz D; Ozyigit G J Appl Clin Med Phys; 2016 Mar; 17(2):14-23. PubMed ID: 27074451 [TBL] [Abstract][Full Text] [Related]
14. Multi-institutional investigation into the robustness of intra-cranial multi-target stereotactic radiosurgery plans to delivery errors. May L; Hardcastle N; Hernandez V; Saez J; Rosenfeld A; Poder J Med Phys; 2024 Feb; 51(2):910-921. PubMed ID: 38141043 [TBL] [Abstract][Full Text] [Related]
15. An EPID-based system for gantry-resolved MLC quality assurance for VMAT. Zwan BJ; Barnes MP; Fuangord T; Stanton CJ; O'Connor DJ; Keall PJ; Greer PB J Appl Clin Med Phys; 2016 Sep; 17(5):348-365. PubMed ID: 27685132 [TBL] [Abstract][Full Text] [Related]
16. IMRT QA and gamma comparisons: The impact of detector geometry, spatial sampling, and delivery technique on gamma comparison sensitivity. Steers JM; Fraass BA Med Phys; 2021 Sep; 48(9):5367-5381. PubMed ID: 34036596 [TBL] [Abstract][Full Text] [Related]
17. An integral quality monitoring system for real-time verification of intensity modulated radiation therapy. Islam MK; Norrlinger BD; Smale JR; Heaton RK; Galbraith D; Fan C; Jaffray DA Med Phys; 2009 Dec; 36(12):5420-8. PubMed ID: 20095254 [TBL] [Abstract][Full Text] [Related]
18. Error detection and classification in patient-specific IMRT QA with dual neural networks. Potter NJ; Mund K; Andreozzi JM; Li JG; Liu C; Yan G Med Phys; 2020 Oct; 47(10):4711-4720. PubMed ID: 33460182 [TBL] [Abstract][Full Text] [Related]
19. Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation. Hirashima H; Miyabe Y; Nakamura M; Mukumoto N; Mizowaki T; Hiraoka M J Appl Clin Med Phys; 2018 May; 19(3):234-242. PubMed ID: 29633542 [TBL] [Abstract][Full Text] [Related]
20. Intrinsic detector sensitivity analysis as a tool to characterize ArcCHECK and EPID sensitivity to variations in delivery for lung SBRT VMAT plans. Alharthi T; Vial P; Holloway L; Thwaites D J Appl Clin Med Phys; 2021 Jun; 22(6):229-240. PubMed ID: 33949087 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]