These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 3331548)

  • 1. [Dimensional differences in stone casts from trays made of different materials].
    Pamir AD
    Ankara Univ Hekim Fak Derg; 1987 May; 14(2):191-5. PubMed ID: 3331548
    [No Abstract]   [Full Text] [Related]  

  • 2. Dimensional accuracy of dental casts: influence of tray material, impression material, and time.
    Thongthammachat S; Moore BK; Barco MT; Hovijitra S; Brown DT; Andres CJ
    J Prosthodont; 2002 Jun; 11(2):98-108. PubMed ID: 12087547
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of using custom or stock trays on the accuracy of gypsum casts.
    Rueda LJ; Sy-Muñoz JT; Naylor WP; Goodacre CJ; Swartz ML
    Int J Prosthodont; 1996; 9(4):367-73. PubMed ID: 8957875
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study.
    Caputi S; Varvara G
    J Prosthet Dent; 2008 Apr; 99(4):274-81. PubMed ID: 18395537
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effects of custom tray material on the accuracy of master casts.
    Shafa S; Zaree Z; Mosharraf R
    J Contemp Dent Pract; 2008 Sep; 9(6):49-56. PubMed ID: 18784859
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The influence of form trays on the reproducibility of stone casts obtained from alginate impressions (author's transl)].
    Sandini MS; de Abreu D
    Estomatol Cult; 1975; 9(1):109-16. PubMed ID: 801872
    [No Abstract]   [Full Text] [Related]  

  • 7. Three-dimensional analysis of dual-arch impression trays.
    Cayouette MJ; Burgess JO; Jones RE; Yuan CH
    Quintessence Int; 2003 Mar; 34(3):189-98. PubMed ID: 12731600
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity.
    Balkenhol M; Ferger P; Wöstmann B
    Int J Prosthodont; 2007; 20(6):573-5. PubMed ID: 18069363
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays.
    Burns J; Palmer R; Howe L; Wilson R
    J Prosthet Dent; 2003 Mar; 89(3):250-5. PubMed ID: 12644799
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Factors affecting the accuracy of elastometric impression materials.
    Chen SY; Liang WM; Chen FN
    J Dent; 2004 Nov; 32(8):603-9. PubMed ID: 15476954
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of stone casts produced by perforated trays and nonperforated trays.
    Woodward JD; Morris JC; Khan Z
    J Prosthet Dent; 1985 Mar; 53(3):347-50. PubMed ID: 3886882
    [No Abstract]   [Full Text] [Related]  

  • 12. Accuracy of casts generated from dual-arch impressions.
    Breeding LC; Dixon DL
    J Prosthet Dent; 2000 Oct; 84(4):403-7. PubMed ID: 11044846
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implant cast accuracy as a function of impression techniques and impression material viscosity.
    Walker MP; Ries D; Borello B
    Int J Oral Maxillofac Implants; 2008; 23(4):669-74. PubMed ID: 18807563
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of adding a stone base on the accuracy of working casts using different types of dental stone.
    Al-Abidi K; Ellakwa A
    J Contemp Dent Pract; 2006 Sep; 7(4):17-28. PubMed ID: 16957787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Impression material trays and models in dental technology].
    Ulber G
    Zahntechnik (Berl); 1983 Dec; 24(12):521-4. PubMed ID: 6377747
    [No Abstract]   [Full Text] [Related]  

  • 16. Accurate dies and well-fitting crowns using three-in-one, all-plastic impression trays.
    Gottlieb M
    Dent Econ; 1996 Jan; 86(1):102-3. PubMed ID: 8612944
    [No Abstract]   [Full Text] [Related]  

  • 17. Accuracy of impression and pouring techniques for an implant-supported prosthesis.
    Del'Acqua MA; Arioli-Filho JN; Compagnoni MA; Mollo Fde A
    Int J Oral Maxillofac Implants; 2008; 23(2):226-36. PubMed ID: 18548918
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection.
    Wenz HJ; Hertrampf K
    Int J Oral Maxillofac Implants; 2008; 23(1):39-47. PubMed ID: 18416411
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster.
    Wise M
    J Prosthet Dent; 2001 Nov; 86(5):532-8. PubMed ID: 11725282
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Using double-poured alginate impressions to fabricate bleaching trays.
    Haywood VB; Powe A
    Oper Dent; 1998; 23(3):128-31. PubMed ID: 9656923
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.