These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 33319318)

  • 1. Method comparison of HPLC-ninhydrin-photometry and UHPLC-PITC-tandem mass spectrometry for serum amino acid analyses in patients with complex congenital heart disease and controls.
    Michel M; Salvador C; Wiedemair V; Adam MG; Laser KT; Dubowy KO; Entenmann A; Karall D; Geiger R; Zlamy M; Scholl-Bürgi S
    Metabolomics; 2020 Dec; 16(12):128. PubMed ID: 33319318
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A targeted metabolomic procedure for amino acid analysis in different biological specimens by ultra-high-performance liquid chromatography-tandem mass spectrometry.
    Casado M; Sierra C; Batllori M; Artuch R; Ormazabal A
    Metabolomics; 2018 May; 14(6):76. PubMed ID: 30830347
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid comprehensive amino acid analysis by liquid chromatography/tandem mass spectrometry: comparison to cation exchange with post-column ninhydrin detection.
    Dietzen DJ; Weindel AL; Carayannopoulos MO; Landt M; Normansell ET; Reimschisel TE; Smith CH
    Rapid Commun Mass Spectrom; 2008 Nov; 22(22):3481-8. PubMed ID: 18853396
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A rapid LC-MS/MS assay for detection and monitoring of underivatized branched-chain amino acids in maple syrup urine disease.
    Piri-Moghadam H; Miller A; Pronger D; Vicente F; Charrow J; Haymond S; Lin DC
    J Mass Spectrom Adv Clin Lab; 2022 Apr; 24():107-117. PubMed ID: 35602306
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A rapid ultra performance liquid chromatography tandem mass spectrometric method for measuring amino acids associated with maple syrup urine disease, tyrosinaemia and phenylketonuria.
    Freeto S; Mason D; Chen J; Scott RH; Narayan SB; Bennett MJ
    Ann Clin Biochem; 2007 Sep; 44(Pt 5):474-81. PubMed ID: 17761035
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of plasma amino acid profile using UHPLC-mass spectrometer (QDa) as a screening method in a metabolic disorders reference centre: Performance and accreditation concerns.
    Bruno C; Veyrat-Durebex C; Lumbu Lukuntonda CH; Andres CR; Moreau C; Bendavid C; Homedan C; Labarthe F; Tardieu M; Bigot A; Maillot F; Benz-de Bretagne I; Blasco H
    Clin Biochem; 2021 Jun; 92():34-45. PubMed ID: 33736999
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid screening of anabolic steroids in horse urine with ultra-high-performance liquid chromatography/tandem mass spectrometry after chemical derivatisation.
    Wong CH; Leung DK; Tang FP; Wong JK; Yu NH; Wan TS
    J Chromatogr A; 2012 Apr; 1232():257-65. PubMed ID: 22265177
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantitative analysis of amino acids and acylcarnitines combined with untargeted metabolomics using ultra-high performance liquid chromatography and quadrupole time-of-flight mass spectrometry.
    Roy C; Tremblay PY; Bienvenu JF; Ayotte P
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Aug; 1027():40-9. PubMed ID: 27240302
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid quantification of underivatized amino acids in plasma by hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass-spectrometry.
    Prinsen HCMT; Schiebergen-Bronkhorst BGM; Roeleveld MW; Jans JJM; de Sain-van der Velden MGM; Visser G; van Hasselt PM; Verhoeven-Duif NM
    J Inherit Metab Dis; 2016 Sep; 39(5):651-660. PubMed ID: 27099181
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A rapid method for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet by ultra performance liquid chromatography-tandem mass spectrometry.
    Wabaidur SM; Alothman ZA; Khan MR
    Spectrochim Acta A Mol Biomol Spectrosc; 2013 May; 108():20-5. PubMed ID: 23454710
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development and validation of a hydrophilic interaction ultra-high-performance liquid chromatography-tandem mass spectrometry method for rapid simultaneous determination of 19 free amino acids in rat plasma and urine.
    Wen Y; Yuan X; Qin F; Zhao L; Xiong Z
    Biomed Chromatogr; 2019 Jan; 33(1):e4387. PubMed ID: 30238479
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of liquid chromatography with tandem mass spectrometry and ion-exchange chromatography by post-column ninhydrin derivatization for amino acid monitoring.
    Smon A; Cuk V; Brecelj J; Murko S; Groselj U; Zerjav Tansek M; Battelino T; Repic Lampret B
    Clin Chim Acta; 2019 Aug; 495():446-450. PubMed ID: 31077651
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry.
    Johansen SS; Bhatia HM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):338-44. PubMed ID: 17301000
    [TBL] [Abstract][Full Text] [Related]  

  • 14. UHPLC assisted simultaneous separation of apigenin and prednisolone and its application in the pharmacokinetics of apigenin.
    Elzayat EM; Shakeel F; Alshehri S; Ibrahim MA; Altamimi MA; Kazi M; Alanazi FK; Haq N
    J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Jun; 1117():58-65. PubMed ID: 30999274
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers: method development and comparative evaluation versus ultra high performance liquid chromatography coupled to Orbitrap high resolution mass spectrometry and triple quadrupole tandem mass spectrometry.
    Zacs D; Rjabova J; Pugajeva I; Nakurte I; Viksna A; Bartkevics V
    J Chromatogr A; 2014 Oct; 1366():73-83. PubMed ID: 25262032
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Challenging the status quo: A comparison of ion exchange chromatography with liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods for the measurement of amino acids in human plasma.
    Carling RS; McDonald BA; Austin D; Burden D; Correia J; Leung J; Mayers B; John C
    Ann Clin Biochem; 2020 Jul; 57(4):277-290. PubMed ID: 32438818
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A liquid chromatography and tandem mass spectrometry method for the determination of potential biomarkers of cardiovascular disease.
    Magiera S; Baranowska I; Kusa J; Baranowski J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Mar; 919-920():20-9. PubMed ID: 23411015
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A quantitative method for acylcarnitines and amino acids using high resolution chromatography and tandem mass spectrometry in newborn screening dried blood spot analysis.
    Miller JH; Poston PA; Karnes HT
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Aug; 903():142-9. PubMed ID: 22846691
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of an ultra-high performance liquid chromatography tandem mass spectrometric method for quantifying uracil and 5,6-dihydrouracil in human plasma.
    Coudoré F; Roche D; Lefeuvre S; Faussot D; Billaud EM; Loriot MA; Beaune P
    J Chromatogr Sci; 2012; 50(10):877-84. PubMed ID: 22689904
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantification of Serum Sulfamethoxazole and Trimethoprim by Ultra-fast Solid-Phase Extraction-Tandem Mass Spectrometry.
    Fatica E; Faber J; Gaffron C; Bjergum M; Langman L; Jannetto P
    Ther Drug Monit; 2020 Oct; 42(5):724-732. PubMed ID: 32618880
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.