BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 33334794)

  • 1. Red Cell Depletion of Major ABO Incompatible Bone Marrow Hematopoietic Progenitor Cells HPC(M) with the Spectra Optia®.
    Christensen A; Hsieh F; Boyer M; Couriel D; Reems JA
    Ann Clin Lab Sci; 2020 Nov; 50(6):781-789. PubMed ID: 33334794
    [TBL] [Abstract][Full Text] [Related]  

  • 2. ABO-mismatched marrow processing for transplantation: Comparative results of 80 procedures performed with Cobe Spectra and Spectra Optia.
    Méndez GA; Arroyo JL; Amunárriz C; Romón Í
    Transfus Apher Sci; 2019 Jun; 58(3):326-331. PubMed ID: 31047824
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Red blood cell depletion in small-volume bone marrow processing using manipulation with third-party red blood cells: A comparison of the performance of the COBE spectra and the spectra Optia systems.
    Sumii Y; Fujii N; Fujii K; Kondo T; Urata T; Kimura M; Washio K; Fujiwara H; Asada N; Ennishi D; Nishimori H; Matsuoka KI; Otsuka F; Maeda Y
    Transfusion; 2022 Sep; 62(9):1829-1838. PubMed ID: 36084209
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictive value of the original content of CD34(+) cells for enrichment of hematopoietic progenitor cells from bone marrow harvests by the apheresis procedure.
    Itoh T; Minegishi M; Kudo Y; Saito N; Takahashi H; Suzuki A; Narita A; Sato Y; Miura J; Inoue Y; Kameoka J; Suwabe N; Imaizumi M; Okuda M; Tsuchiya S
    J Clin Apher; 2006 Oct; 21(3):176-80. PubMed ID: 16619225
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Red blood cell depletion from bone marrow and peripheral blood buffy coat: a comparison of two new and three established technologies.
    Sorg N; Poppe C; Bunos M; Wingenfeld E; Hümmer C; Krämer A; Stock B; Seifried E; Bonig H
    Transfusion; 2015 Jun; 55(6):1275-82. PubMed ID: 25647556
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Erythrocyte depletion from bone marrow: performance evaluation after 50 clinical-scale depletions with Spectra Optia BMC.
    Kim-Wanner SZ; Bug G; Steinmann J; Ajib S; Sorg N; Poppe C; Bunos M; Wingenfeld E; Hümmer C; Luxembourg B; Seifried E; Bonig H
    J Transl Med; 2017 Aug; 15(1):174. PubMed ID: 28800741
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optia® continuous mononuclear collection (CMNC) system is a safe and efficient system for hematopoietic progenitor cells-apheresis (HPC-a) collection and yields a lower product hematocrit (HCT%) than the COBE® spectra system: A retrospective study.
    Pandey S; Cottler-Fox M
    J Clin Apher; 2018 Aug; 33(4):505-513. PubMed ID: 29603795
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Retrospective comparison between COBE SPECTRA and SPECTRA OPTIA apheresis systems for hematopoietic progenitor cells collection for autologous and allogeneic transplantation in a single center.
    López-Pereira P; Sola Aparicio E; Vicuña Andrés I; Cámara Montejano C; Muñoz Calleja C; Alegre Amor A; Aguado Bueno B
    J Clin Apher; 2020 Sep; 35(5):453-459. PubMed ID: 32798328
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of Haemonetics Cell Saver 5+ and manual density separation for optimum depletion of red blood cells and preservation of CD34
    Qudeimat A; Zandaki D; Bi Y; Li Y; Davis K; Alloush L; Selukar S; Triplett B; Akel S; Srinivasan A
    Cytotherapy; 2023 Nov; 25(11):1145-1148. PubMed ID: 37598335
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Human bone marrow processing using a new continuous-flow cell separation device.
    Guttridge MG; Bailey C; Sidders C; Nichols J; Bromham J; Watt SM
    Transfusion; 2016 Apr; 56(4):899-904. PubMed ID: 26662223
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Infusion hemolysis after pediatric major ABO-mismatched bone marrow transplant: Comparison of two red blood cell depletion techniques.
    Nickel RS; Qayed M; Worthington-White D; Stowell SR; Chiang KY
    Pediatr Blood Cancer; 2018 Mar; 65(3):. PubMed ID: 29115715
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Collection of peripheral blood stem cells from ABO incompatible allogeneic donors by using blood cell separator].
    Ma SX; Liu JH; Li XJ; Wang TJ; Ouyang XL; Bai LX; Gao CJ; Zhu HY
    Zhongguo Shi Yan Xue Ye Xue Za Zhi; 2005 Jun; 13(3):496-9. PubMed ID: 15972150
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factors affecting volume reduction and red blood cell depletion of bone marrow on the COBE Spectra cell separator before haematopoietic stem cell transplantation.
    Guttridge MG; Sidders C; Booth-Davey E; Pamphilon D; Watt SM
    Bone Marrow Transplant; 2006 Aug; 38(3):175-81. PubMed ID: 16770313
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of two apheresis systems during hematopoietic progenitor stem cell collections at a tertiary medical center.
    Li Y; Li J; Reeves HM; Reyes R; Maitta RW
    Transfusion; 2016 Nov; 56(11):2833-2838. PubMed ID: 27487161
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of two protocols for optimal red blood cell depletion using Sepax-2 device for ABO-major incompatible transplantation in adults.
    Fantin L; Olivieri CV; Spirito-Daffara F; Doglio A; Olivero S
    Curr Res Transl Med; 2019 Aug; 67(3):107-111. PubMed ID: 30935875
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Processing of major ABO-incompatible bone marrow for transplantation by using dextran sedimentation.
    Tsang KS; Li CK; Wong AP; Leung Y; Lau TT; Li K; Shing MM; Chik KW; Yuen PM
    Transfusion; 1999; 39(11-12):1212-9. PubMed ID: 10604248
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Allogeneic donor peripheral blood "stem cell" apheresis: prospective comparison of two apheresis systems.
    Brauninger S; Bialleck H; Thorausch K; Felt T; Seifried E; Bonig H
    Transfusion; 2012 May; 52(5):1137-45. PubMed ID: 22044384
    [TBL] [Abstract][Full Text] [Related]  

  • 18. ABO-mismatched marrow processing for transplantation: results of 114 procedures and analysis of immediate adverse events and hematopoietic recovery.
    Larghero J; Rea D; Esperou H; Biscay N; Maurer MN; Lacassagne MN; Ternaux B; Traineau R; Yakouben K; Dosquet C; Socié G; Gluckman E; Benbunan M; Marolleau JP
    Transfusion; 2006 Mar; 46(3):398-402. PubMed ID: 16533282
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of harvest product volume in erythrocyte depletion of allogeneic or autologous bone marrow using COBE spectra.
    Soydan E; Ayyildiz E; Dalva K; Topçuoğlu P; Tol M; Arslan O; Ilhan O; Arat M
    Transfus Apher Sci; 2007 Jun; 36(3):269-73. PubMed ID: 17574924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy and kinetics of bone marrow processing and enrichment of haematopoietic progenitor cells (HPC) by a large-volume apheresis procedure.
    Cassens U; Ostkamp-Ostermann P; Garritsen H; Kelsch R; Ostermann H; Kienast J; Kiehl M; Buechner T; van de Loo J; Juergens H; Sibrowski W
    Bone Marrow Transplant; 1997 Apr; 19(8):835-40. PubMed ID: 9134178
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.