These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 3333583)

  • 1. [Accuracy of post impression in various directions. Combined reversible/irreversible hydrocolloid impression].
    Warita K
    Nihon Hotetsu Shika Gakkai Zasshi; 1987 Aug; 31(4):997-1010. PubMed ID: 3333583
    [No Abstract]   [Full Text] [Related]  

  • 2. The combined reversible hydrocolloid/irreversible hydrocolloid impression system: clinical application.
    Appleby DC; Cohen SR; Racowsky LP; Mingledorff EB
    J Prosthet Dent; 1981 Jul; 46(1):48-58. PubMed ID: 7024517
    [No Abstract]   [Full Text] [Related]  

  • 3. [Studies on the accuracy of elastomeric impression materials. Part 2. Comparison of dimensional accuracy of casts made by both single polyether rubber impression and the combined reversible and irreversible hydrocolloid impression technique (author's transl)].
    Shigeto N; Inohara N; Yamada S
    Hiroshima Daigaku Shigaku Zasshi; 1978; 10(1):98-108. PubMed ID: 396327
    [No Abstract]   [Full Text] [Related]  

  • 4. The combined reversible hydrocolloid/irreversible hydrocolloid impression system.
    Appleby DC; Pameijer CH; Boffa J
    J Prosthet Dent; 1980 Jul; 44(1):27-35. PubMed ID: 6991676
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dimensional accuracy of combined reversible and irreversible hydrocolloid impression materials.
    Supowitz ML; Schnell RJ; Dykema RW; Goodacre CJ
    J Prosthet Dent; 1988 Apr; 59(4):404-9. PubMed ID: 3283324
    [No Abstract]   [Full Text] [Related]  

  • 6. Comparison of the dimensional accuracy of a combined reversible/irreversible hydrocolloid impression system with other commonly used impression materials.
    Herring HW; Tames MA; Zardiackas LD
    J Prosthet Dent; 1984 Dec; 52(6):795-9. PubMed ID: 6392511
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of reversible hydrocolloid impression material in a wet field.
    Stewart GP; Bagley RL; Froemling RA
    J Prosthet Dent; 1984 Jun; 51(6):797-800. PubMed ID: 6376782
    [No Abstract]   [Full Text] [Related]  

  • 8. Combined reversible/irreversible hydrocolloid impression systems: comparative analysis.
    Appleby DC; Smith W; Lontz JF; Mingledorff EB
    J Prosthet Dent; 1985 Nov; 54(5):627-32. PubMed ID: 3903131
    [No Abstract]   [Full Text] [Related]  

  • 9. The effects of disposable and custom-made impression trays on the accuracy of impressions.
    Burton JF; Hood JA; Plunkett DJ; Johnson SS
    J Dent; 1989 Jun; 17(3):121-3. PubMed ID: 2671076
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Relating the marginal fit of the castings to the accuracy of the impressions made from laminated hydrocolloid impression technique: a comparative study.
    Sinha MR; Thakur B; Gaikwad A; Chaudhari LD; Kulkarni A; Kulkarni H
    J Contemp Dent Pract; 2012 Mar; 13(2):167-72. PubMed ID: 22665742
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hydrocolloid impressions of multirooted teeth: a clinical report.
    Ferrari M; Balleri P
    Quintessence Int; 1993 Jan; 24(1):35-7. PubMed ID: 8511256
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and bond strength of reversible with irreversible hydrocolloid impression systems: a comparative study.
    Heisler WH; Tjan AH
    J Prosthet Dent; 1992 Oct; 68(4):578-84. PubMed ID: 1403933
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical evaluation of reversible/irreversible hydrocolloid impression systems.
    Kelsey WP; Blankenau RJ; Cavel WT; Barkmeier WW
    Gen Dent; 1988; 36(6):506-7. PubMed ID: 3078308
    [No Abstract]   [Full Text] [Related]  

  • 14. [Comparative study of a new irreversible hydrocolloid].
    Brugirard JL
    SSO Schweiz Monatsschr Zahnheilkd; 1983 Jun; 93(6):455-62. PubMed ID: 6351246
    [No Abstract]   [Full Text] [Related]  

  • 15. Accuracy of a hydrophilic irreversible hydrocolloid/silicone impression material.
    Davis DR; Preble JS
    J Prosthet Dent; 1986 Mar; 55(3):304-8. PubMed ID: 3514871
    [No Abstract]   [Full Text] [Related]  

  • 16. Reversible hydrocolloid impression techniques.
    Brady WF
    CDA J; 1985 Aug; 13(8):40-7. PubMed ID: 3896526
    [No Abstract]   [Full Text] [Related]  

  • 17. The influence of impression trays on the accuracy of stone casts poured from irreversible hydrocolloid impressions.
    Mendez AJ
    J Prosthet Dent; 1985 Sep; 54(3):383-8. PubMed ID: 3906093
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Check bite impressions using irreversible alginate/reversible hydrocolloid combination.
    Scott GK; Hawkins L; Chetwyn J; Doughty T
    J Prosthet Dent; 1997 Jan; 77(1):83-5. PubMed ID: 9029470
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Factors that affect the adhesion of two irreversible hydrocolloid materials to two custom tray materials.
    Smith SJ; McCord JF; Macfarlane TV
    J Prosthet Dent; 2002 Oct; 88(4):423-30. PubMed ID: 12447220
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Wax impression for the Richmond crown].
    Jovanović D
    Stomatol Vjesn; 1968; 2(1-6):493-7. PubMed ID: 4951112
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.