These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 33337570)

  • 1. Ultrasound guided axillary vein access: An alternative approach to venous access for cardiac device implantation.
    Chandler JK; Apte N; Ranka S; Mohammed M; Noheria A; Emert M; Pimentel R; Dendi R; Reddy M; Sheldon SH
    J Cardiovasc Electrophysiol; 2021 Feb; 32(2):458-465. PubMed ID: 33337570
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Axillary vein access for permanent pacemaker and implantable cardioverter defibrillator implantation: Fluoroscopy compared to ultrasound.
    Migliore F; Fais L; Vio R; De Lazzari M; Zorzi A; Bertaglia E; Iliceto S
    Pacing Clin Electrophysiol; 2020 Jun; 43(6):566-572. PubMed ID: 32394452
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fluoroscopy-guided axillary vein access vs cephalic vein access in pacemaker and defibrillator implantation: Randomized clinical trial of efficacy and safety.
    Jiménez-Díaz J; Higuera-Sobrino F; Piqueras-Flores J; Pérez-Díaz P; González-Marín MA
    J Cardiovasc Electrophysiol; 2019 Sep; 30(9):1588-1593. PubMed ID: 31310038
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrasound-guided axillary venous access for pediatric and adult congenital lead implantation.
    Clark BC; Janson CM; Nappo L; Pass RH
    Pacing Clin Electrophysiol; 2019 Feb; 42(2):166-170. PubMed ID: 30515865
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Axillary vein puncture guided by ultrasound vs cephalic vein dissection in pacemaker and defibrillator implant: A multicenter randomized clinical trial.
    Tagliari AP; Kochi AN; Mastella B; Saadi RP; di Leoni Ferrari A; Saadi EK; Polanczyk CA
    Heart Rhythm; 2020 Sep; 17(9):1554-1560. PubMed ID: 32360827
    [TBL] [Abstract][Full Text] [Related]  

  • 6. UltraSound Axillary Vein Access (USAA): Learning curve and randomized comparison to traditional venous access for cardiac device implantation.
    Courtney AM; Chandler JK; Anderson J; Shrestha A; Noheria A; Pimentel R; Dendi R; Ramirez R; Reddy YM; Sheldon SH
    Pacing Clin Electrophysiol; 2022 Dec; 45(12):1364-1371. PubMed ID: 36270271
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intra-pocket ultrasound-guided axillary vein puncture vs. cephalic vein cutdown for cardiac electronic device implantation: the ACCESS trial.
    Charles P; Ditac G; Montoy M; Thenard T; Courand PY; Lantelme P; Harbaoui B; Fareh S
    Eur Heart J; 2023 Dec; 44(46):4847-4858. PubMed ID: 37832512
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasound-guided access to the axillary vein for implantation of cardiac implantable electronic devices: A systematic review and meta-analysis.
    D'Arrigo S; Perna F; Annetta MG; Pittiruti M
    J Vasc Access; 2023 Jul; 24(4):854-863. PubMed ID: 34724839
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound-Guided Venous Axillary Access Versus Standard Fluoroscopic Technique for Cardiac Lead Implantation: ZEROFLUOROAXI Randomized Trial.
    Vitali F; Malagù M; Bianchi N; De Raffele M; Manfrini M; Gibiino F; Boccadoro A; Azzolini G; Balla C; Bertini M
    JACC Clin Electrophysiol; 2024 Mar; 10(3):554-565. PubMed ID: 38243998
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasound versus fluoroscopy-guided axillary vein access for cardiac device implantation.
    Bun SS; Taghji P; Squara F; Massoure PL; Deharo JC; Ferrari E
    Rev Esp Cardiol (Engl Ed); 2023 Aug; 76(8):659-660. PubMed ID: 36842633
    [No Abstract]   [Full Text] [Related]  

  • 11. Predictors, Morbidity, and Costs Associated with Pneumothorax during Electronic Cardiac Device Implantation.
    Kotter J; Lolay G; Charnigo R; Leung S; McKibbin C; Sousa M; Jimenez L; Gurley J; Biase LD; Natale A; Smyth S; Darrat Y; Morales G; Elayi CS
    Pacing Clin Electrophysiol; 2016 Sep; 39(9):985-91. PubMed ID: 27230623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Body mass index is related to unsuccessful puncture attempts and failure to axillary vein cannulation during ultrasound-guided cardiac electronic device implantation.
    De Sensi F; Addonisio L; Baratta P; Breschi M; Cresti A; Miracapillo G; Limbruno U
    J Interv Card Electrophysiol; 2021 Aug; 61(2):253-259. PubMed ID: 32572722
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictors of successful ultrasound-guided lead implantation.
    Ahmed AS; Gilge JL; Clark BA; Shah A; Bagga S; Padanilam MS; Prystowsky EN; Joshi SA; Nair GV; Patel PJ
    Pacing Clin Electrophysiol; 2020 Feb; 43(2):217-222. PubMed ID: 31808167
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study.
    Liccardo M; Nocerino P; Gaia S; Ciardiello C
    J Interv Card Electrophysiol; 2018 Mar; 51(2):153-160. PubMed ID: 29335840
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility of ultrasound-guided vascular access during cardiac implantable device placement.
    Lin J; Adsit G; Barnett A; Tattersall M; Field ME; Wright J
    J Interv Card Electrophysiol; 2017 Oct; 50(1):105-109. PubMed ID: 28752227
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Axillary vein technique for pacemaker and implantable defibrillator leads implantation: a safe and alternative approach?
    Migliore F; Curnis A; Bertaglia E
    J Cardiovasc Med (Hagerstown); 2016 Apr; 17(4):309-13. PubMed ID: 25252042
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Low lateral thoracic site for cardiac implantable electronic device implantation: A viable alternative in patients with limited access options after infected device extraction.
    Liang JJ; Schaller RD; Modi DS; Enriquez A; Supple GE; Cooper JM
    Heart Rhythm; 2017 Oct; 14(10):1506-1514. PubMed ID: 28603001
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads.
    Migliore F; Siciliano M; De Lazzari M; Ferretto S; Valle CD; Zorzi A; Corrado D; Iliceto S; Bertaglia E
    J Interv Card Electrophysiol; 2015 Sep; 43(3):263-7. PubMed ID: 25956478
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultrasound-guided venous access for pacemakers and defibrillators.
    Seto AH; Jolly A; Salcedo J
    J Cardiovasc Electrophysiol; 2013 Mar; 24(3):370-4. PubMed ID: 23131025
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contrast venography vs. microwire assisted axillary venipuncture for cardiovascular implantable electronic device implantation.
    Beig JR; Ganai BA; Alai MS; Lone AA; Hafeez I; Dar MI; Tramboo NA; Rather HA
    Europace; 2018 Aug; 20(8):1318-1323. PubMed ID: 29036554
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.