BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 33341353)

  • 1. Clinical and radiological outcomes of total hip arthroplasty using a highly porous titanium cup or a conventional hydroxyapatite-coated titanium cup: A retrospective study in Japanese patients.
    Tamaki Y; Goto T; Takasago T; Wada K; Hamada D; Sairyo K
    J Orthop Sci; 2022 Jan; 27(1):163-168. PubMed ID: 33341353
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of a highly porous titanium cup (Tritanium) and a conventional hydroxyapatite-coated porous titanium cup: A retrospective analysis of clinical and radiological outcomes in hip arthroplasty among Japanese patients.
    Yoshioka S; Nakano S; Kinoshita Y; Nakamura M; Goto T; Hamada D; Sairyo K
    J Orthop Sci; 2018 Nov; 23(6):967-972. PubMed ID: 30055877
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical and radiological outcomes of total hip arthroplasty in octogenarian patients using a three-dimensional porous titanium cup: a retrospective analysis in Japanese patients.
    Kaneko T; Nakamura S; Hayakawa K; Tokimura F; Miyazaki T
    Eur J Orthop Surg Traumatol; 2023 Aug; 33(6):2361-2367. PubMed ID: 36414875
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis.
    Miyagawa T; Matsumoto K; Komura S; Akiyama H
    BMC Musculoskelet Disord; 2021 Mar; 22(1):308. PubMed ID: 33771146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A New Additive-Manufactured Cementless Highly Porous Titanium Acetabular Cup for Primary Total Hip Arthroplasty-Early Two-Year Follow Up.
    Abdelaal MS; Small I; Restrepo C; Hozack WJ
    Surg Technol Int; 2021 May; 38():393-398. PubMed ID: 33724435
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiolucent lines do not affect the longevity of highly cross-linked polyethylene cemented components in total hip arthroplasty.
    Takaoka Y; Goto K; Tamura J; Okuzu Y; Kawai T; Kuroda Y; Orita K; Matsuda S
    Bone Joint J; 2021 Oct; 103-B(10):1604-1610. PubMed ID: 34587810
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients.
    Geng X; Li Y; Li F; Wang X; Zhang K; Liu Z; Tian H
    J Orthop Surg Res; 2020 Sep; 15(1):383. PubMed ID: 32887636
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimum 7-year Follow-up of A Porous Coated Trabecular Titanium Cup Manufactured with Electron Beam Melting Technique in Primary Total Hip Arthroplasty.
    Huang Y; Zhou YX; Tian H; Wang JW; Liu WG; Li H
    Orthop Surg; 2021 May; 13(3):817-824. PubMed ID: 33728818
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Survivorship and Radiographic Analysis of Highly Porous Acetabular Cups Designed for Improved Osseointegration Potential.
    Sodhi N; Khlopas A; Berliner Z; Dushaj K; Minter JE; Naylor B; Marchand R; Hepinstall MS; Mont MA
    Surg Technol Int; 2019 May; 34():425-429. PubMed ID: 30753741
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Highly Porous Titanium Cups Frequently Presenting with Radiolucent Lines in Cementless Primary Total Hip Arthroplasty: A Retrospective Cohort Study.
    Ohta Y; Sugama R; Minoda Y; Mizokawa S; Takahashi S; Ikebuchi M; Nakatsuchi T; Nakamura H
    J Clin Med; 2024 Jun; 13(11):. PubMed ID: 38893007
    [No Abstract]   [Full Text] [Related]  

  • 11. Do tantalum and titanium cups show similar results in revision hip arthroplasty?
    Jafari SM; Bender B; Coyle C; Parvizi J; Sharkey PF; Hozack WJ
    Clin Orthop Relat Res; 2010 Feb; 468(2):459-65. PubMed ID: 19809857
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Absence of Hydroxyapatite Coating on Cementless Acetabular Components Does Not Affect Long-Term Survivorship in Total Hip Arthroplasty.
    Sato T; Nakashima Y; Komiyama K; Yamamoto T; Motomura G; Iwamoto Y
    J Arthroplasty; 2016 Jun; 31(6):1228-1232. PubMed ID: 26730449
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of a new off-the-shelf 3D-printed trabecular titanium acetabular cup in Chinese patients undergoing hip revision surgery: Short- to mid-term clinical and radiological outcomes.
    Shang G; Xiang S; Guo C; Guo J; Wang P; Wang Y; Xu H
    BMC Musculoskelet Disord; 2022 Jul; 23(1):636. PubMed ID: 35787270
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Highly Porous Titanium Acetabular Components in Primary and Revision Total Hip Arthroplasty: A Systematic Review.
    Malahias MA; Kostretzis L; Greenberg A; Nikolaou VS; Atrey A; Sculco PK
    J Arthroplasty; 2020 Jun; 35(6):1737-1749. PubMed ID: 32070658
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty.
    Castagnini F; Bordini B; Yorifuji M; Giardina F; Natali S; Pardo F; Traina F
    Med Princ Pract; 2019; 28(6):559-565. PubMed ID: 31079112
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Midterm Outcomes of Revision Total Hip Arthroplasty With the Use of a Multihole Highly-Porous Titanium Shell.
    Delanois RE; Gwam CU; Mohamed N; Khlopas A; Chughtai M; Malkani AL; Mont MA
    J Arthroplasty; 2017 Sep; 32(9):2806-2809. PubMed ID: 28456559
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty.
    Oishi K; Yamamoto Y; Harada Y; Inoue R; Sasaki E; Ishibashi Y
    J Orthop Surg Res; 2021 Apr; 16(1):266. PubMed ID: 33858459
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term results of combined porous tantalum augments and titanium-coated cups for Paprosky type III bone defects in acetabular revision.
    Xiao Q; Xu B; Zhou K; Ling T; Yuan M; Pei F; Zhou Z
    Int Orthop; 2021 Jul; 45(7):1699-1706. PubMed ID: 34019127
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trial.
    Salemyr M; Muren O; Eisler T; Bodén H; Chammout G; Stark A; Sköldenberg O
    Int Orthop; 2015 May; 39(5):823-32. PubMed ID: 25338110
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Results at a minimum of 10 years of follow-up for AMS and PerFix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity.
    Nakashima Y; Sato T; Yamamoto T; Motomura G; Ohishi M; Hamai S; Akiyama M; Hirata M; Hara D; Iwamoto Y
    J Orthop Sci; 2013 Nov; 18(6):962-8. PubMed ID: 23963589
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.