BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

387 related articles for article (PubMed ID: 33342692)

  • 1. A disposable smart microfluidic platform integrated with on-chip flow sensors.
    Kim J; Cho H; Kim J; Park JS; Han KH
    Biosens Bioelectron; 2021 Mar; 176():112897. PubMed ID: 33342692
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A disposable microfluidic device with a reusable magnetophoretic functional substrate for isolation of circulating tumor cells.
    Cho H; Kim J; Jeon CW; Han KH
    Lab Chip; 2017 Nov; 17(23):4113-4123. PubMed ID: 29094741
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lateral Degassing Method for Disposable Film-Chip Microfluidic Devices.
    Park S; Cho H; Kim J; Han KH
    Membranes (Basel); 2021 Apr; 11(5):. PubMed ID: 33925874
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optofluidic bioimaging platform for quantitative phase imaging of lab on a chip devices using digital holographic microscopy.
    Pandiyan VP; John R
    Appl Opt; 2016 Jan; 55(3):A54-9. PubMed ID: 26835958
    [TBL] [Abstract][Full Text] [Related]  

  • 5. dDrop-Chip: disposable film-chip microfluidic device for real-time droplet feedback control.
    Ryu J; Kim J; Han KH
    Lab Chip; 2023 Mar; 23(7):1896-1904. PubMed ID: 36877075
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Self-Priming Microfluidic Chip with Cushion Chambers for Easy Digital PCR.
    Xu G; Si H; Jing F; Sun P; Wu D
    Biosensors (Basel); 2021 May; 11(5):. PubMed ID: 34069758
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Recent developments in optical detection technologies in lab-on-a-chip devices for biosensing applications.
    Pires NM; Dong T; Hanke U; Hoivik N
    Sensors (Basel); 2014 Aug; 14(8):15458-79. PubMed ID: 25196161
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An automated and portable microfluidic chemiluminescence immunoassay for quantitative detection of biomarkers.
    Hu B; Li J; Mou L; Liu Y; Deng J; Qian W; Sun J; Cha R; Jiang X
    Lab Chip; 2017 Jun; 17(13):2225-2234. PubMed ID: 28573279
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Solid-State Microfluidics with Integrated Thin-Film Acoustic Sensors.
    Zhang M; Huang J; Lu Y; Pang W; Zhang H; Duan X
    ACS Sens; 2018 Aug; 3(8):1584-1591. PubMed ID: 30039702
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of Flow-Induced Microfluidic Chip Wall Deformation on Imaging Flow Cytometry.
    Yalikun Y; Ota N; Guo B; Tang T; Zhou Y; Lei C; Kobayashi H; Hosokawa Y; Li M; Enrique Muñoz H; Di Carlo D; Goda K; Tanaka Y
    Cytometry A; 2020 Sep; 97(9):909-920. PubMed ID: 31856398
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An All-Glass Microfluidic Network with Integrated Amorphous Silicon Photosensors for on-Chip Monitoring of Enzymatic Biochemical Assay.
    Costantini F; Tiggelaar RM; Salvio R; Nardecchia M; Schlautmann S; Manetti C; Gardeniers HJGE; de Cesare G; Caputo D; Nascetti A
    Biosensors (Basel); 2017 Dec; 7(4):. PubMed ID: 29206205
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomedical Applications of Microfluidic Devices: A Review.
    Gharib G; Bütün İ; Muganlı Z; Kozalak G; Namlı İ; Sarraf SS; Ahmadi VE; Toyran E; van Wijnen AJ; Koşar A
    Biosensors (Basel); 2022 Nov; 12(11):. PubMed ID: 36421141
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Identification of microfluidic two-phase flow patterns in lab-on-chip devices.
    Yang Z; Dong T; Halvorsen E
    Biomed Mater Eng; 2014; 24(1):77-83. PubMed ID: 24211885
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Digital microfluidic meter-on-chip.
    Fang Z; Ding Y; Zhang Z; Wang F; Wang Z; Wang H; Pan T
    Lab Chip; 2020 Feb; 20(4):722-733. PubMed ID: 31853525
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of Chip Inlet Geometry in Microfluidic Devices for Cell Studies.
    Sun YS
    Molecules; 2016 Jun; 21(6):. PubMed ID: 27314318
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integrated optofluidic-microfluidic twin channels: toward diverse application of lab-on-a-chip systems.
    Lv C; Xia H; Guan W; Sun YL; Tian ZN; Jiang T; Wang YS; Zhang YL; Chen QD; Ariga K; Yu YD; Sun HB
    Sci Rep; 2016 Jan; 6():19801. PubMed ID: 26823292
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Additively Manufactured Digital Microfluidic Platforms for Ion-Selective Sensing.
    Min X; Bao C; Kim WS
    ACS Sens; 2019 Apr; 4(4):918-923. PubMed ID: 30855128
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A disposable emulsion droplet generation lab chips driven by vacuum module for manipulation of blood cells.
    Chia-Hung Lee ; Chien-Chong Hong
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():8010-3. PubMed ID: 26738151
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Manufacturing of Microfluidic Devices with Interchangeable Commercial Fiber Optic Sensors.
    Wlodarczyk KL; MacPherson WN; Hand DP; Maroto-Valer MM
    Sensors (Basel); 2021 Nov; 21(22):. PubMed ID: 34833567
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Digital monitoring of the microchannel filling flow dynamics using a non-contactless smartphone-based nano-liter precision flow velocity meter.
    Xu W; Atik AY; Beker L; Ceylan Koydemir H
    Biosens Bioelectron; 2024 May; 252():116130. PubMed ID: 38417285
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.