207 related articles for article (PubMed ID: 33346049)
1. Forming the Simmons Catheter for Cerebral Angiography and Neurointerventions via the Transradial Approach-Techniques and Operative Videos.
Hadley C; Srinivasan V; Burkhardt JK; Johnson J; Luther E; Strickland A; Starke RM; Kan P
World Neurosurg; 2021 Mar; 147():e351-e353. PubMed ID: 33346049
[TBL] [Abstract][Full Text] [Related]
2. Left Transradial Neurointerventions Using the 6-French Simmons Guiding Sheath: Initial Experiences with the Interchange Technique.
Ito H; Uchida M; Takasuna H; Goto T; Takumi I; Fukano T; Hagiwara Y; Tanaka Y
World Neurosurg; 2021 Aug; 152():e344-e351. PubMed ID: 34087460
[TBL] [Abstract][Full Text] [Related]
3. A new very-small-bore Simmons guiding sheath for transradial neurointervention: Technical note and initial experience.
Hanaoka Y; Abe D; Koyama JI; Nakamura T; Kitamura S; Horiuchi T
J Neuroradiol; 2024 Mar; 51(2):214-219. PubMed ID: 37625629
[TBL] [Abstract][Full Text] [Related]
4. Pigtail catheter exchange technique for the Simmons catheter formation in transradial cerebral angiography.
Wu C; Qi DY; Zhu DY; Du M; He JL; Ye SF; Zheng TH; Fang YB
Clin Neurol Neurosurg; 2023 Jul; 230():107791. PubMed ID: 37269605
[TBL] [Abstract][Full Text] [Related]
5. Transradial approach for carotid artery stenting: a feasibility study.
Folmar J; Sachar R; Mann T
Catheter Cardiovasc Interv; 2007 Feb; 69(3):355-61. PubMed ID: 17230545
[TBL] [Abstract][Full Text] [Related]
6. Transradial Approach as the Primary Vascular Access with a 6-Fr Simmons Guiding Sheath for Anterior Circulation Interventions: A Single-Center Case Series of 130 Consecutive Patients.
Hanaoka Y; Koyama JI; Yamazaki D; Miyaoka Y; Fujii Y; Nakamura T; Ogiwara T; Ito K; Horiuchi T
World Neurosurg; 2020 Jun; 138():e597-e606. PubMed ID: 32165342
[TBL] [Abstract][Full Text] [Related]
7. Initial Experience with Left Transradial Neurointerventions for Cerebral Aneurysms Using the 6-French Simmons Guiding Sheath.
Uchida M; Ito H; Takasuna H; Goto T; Takumi I; Fukano T; Hagiwara Y; Tanaka Y
J Stroke Cerebrovasc Dis; 2022 Apr; 31(4):106350. PubMed ID: 35152132
[TBL] [Abstract][Full Text] [Related]
8. Left Transradial Access Using a Radial-Specific Neurointerventional Guiding Sheath for Coil Embolization of Anterior Circulation Aneurysm Associated With the Aberrant Right Subclavian Artery: Technical Note and Literature Review.
Inomata Y; Hanaoka Y; Koyama JI; Yamazaki D; Kitamura S; Nakamura T; Horiuchi T
World Neurosurg; 2023 Oct; 178():126-131. PubMed ID: 37506842
[TBL] [Abstract][Full Text] [Related]
9. The 'Trawl Fishing' Technique: A Quick Engagement of the Left Common Carotid Artery With the Simmons Catheter During Carotid Artery Stenting From the Right Radial Approach.
Montorsi P; Galli S; Teruzzi G; Gili S; Trabattoni D
Cardiovasc Revasc Med; 2023 Sep; 54():57-60. PubMed ID: 37085354
[TBL] [Abstract][Full Text] [Related]
10. Adapting to transradial approach in cerebral angiography: Factors influencing successful cannulation.
Yaser Arafath M; Bhatia V; Kumar A; Chauhan R; Prabhakar A; Gupta SK; Singh P
Neuroradiol J; 2023 Apr; 36(2):163-168. PubMed ID: 35749090
[TBL] [Abstract][Full Text] [Related]
11. Transradial Stenting for Carotid Stenosis in Patients with Bovine Type and Type III Aortic Arch: Experience in 28 Patients.
Gao BL; Xu GQ; Wang ZL; Li TX; Wang YF; Liang XD; Yang BW
World Neurosurg; 2018 Mar; 111():e661-e667. PubMed ID: 29294393
[TBL] [Abstract][Full Text] [Related]
12. Radial Access Techniques.
Luther E; Burks J; McCarthy DJ; Govindarajan V; Nada A; Saini V; Jamshidi A; King H; Heath R; Silva M; Abecassis IJ; Starke RM
Neurosurg Clin N Am; 2022 Apr; 33(2):149-159. PubMed ID: 35346447
[TBL] [Abstract][Full Text] [Related]
13. Effectiveness of a handmade "New Carotid Catheter" in transradial carotid angiography: A comparison with conventional multipurpose catheters.
Balaban Y
J Interv Cardiol; 2018 Feb; 31(1):94-105. PubMed ID: 29024265
[TBL] [Abstract][Full Text] [Related]
14. Stenting the carotid artery from radial access using a Simmons guide catheter.
Heck D; Jost A; Howard G
J Neurointerv Surg; 2022 Feb; 14(2):169-173. PubMed ID: 33632887
[TBL] [Abstract][Full Text] [Related]
15. [Transradial approach in carotid stenting].
Shchanitsyn IN; Sharafutdinov MR; Iakubov RA; Larin IV
Angiol Sosud Khir; 2018; 24(2):114-122. PubMed ID: 29924782
[TBL] [Abstract][Full Text] [Related]
16. Application of pigtail catheter tailing combined with long-wire swapping technique in cerebral angiography via the right radial artery.
Yan D; Zhu B; Li Q; Peng T; Jiang J; Liu J; Dan B
Medicine (Baltimore); 2020 Sep; 99(39):e22309. PubMed ID: 32991437
[TBL] [Abstract][Full Text] [Related]
17. Radial Artery Access for Cerebral Angiography: 2-Dimensional Operative Video.
Chen SH; Suazo R; Saini V; Abecassis IJ; Yavagal D; Starke RM; Peterson EC
Oper Neurosurg (Hagerstown); 2021 May; 20(6):E431-E432. PubMed ID: 33861323
[TBL] [Abstract][Full Text] [Related]
18. Contralateral transradial approach for carotid artery stenting: a feasibility study.
Patel T; Shah S; Ranjan A; Malhotra H; Pancholy S; Coppola J
Catheter Cardiovasc Interv; 2010 Feb; 75(2):268-75. PubMed ID: 19890939
[TBL] [Abstract][Full Text] [Related]
19. The concept of an anatomy related individual arterial access: lowering technical and clinical complications with transradial access in bovine- and type-III aortic arch carotid artery stenting.
Dahm JB; van Buuren F; Hansen C; Becker J; Wolpers HG
Vasa; 2011 Nov; 40(6):468-73. PubMed ID: 22090180
[TBL] [Abstract][Full Text] [Related]
20. Usefulness of a Novel Technique to Make Up for a Deficiency in Transradial Neurointervention with a 6Fr Simmonds Guiding Sheath: Original Experience with the Subclavian Artery Anchoring Technique.
Hanaoka Y; Koyama JI; Ogiwara T; Miyaoka Y; Fujii Y; Nakamura T; Horiuchi T; Hongo K
World Neurosurg; 2019 Nov; 131():e362-e370. PubMed ID: 31362101
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]