BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 33347093)

  • 1. Diagnostic Accuracy of Thresholds Less Than or Equal to 8 mA in Pedicle Screw Testing During Lumbar Spine Procedures to Predict New Postoperative Lower Extremity Neurological Deficits.
    Melachuri SR; Melachuri MK; Anetakis K; Crammond DJ; Balzer JR; Thirumala PD
    Spine (Phila Pa 1976); 2021 Jan; 46(2):E139-E145. PubMed ID: 33347093
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimal "Low" Pedicle Screw Stimulation Threshold to Predict New Postoperative Lower-Extremity Neurologic Deficits During Lumbar Spinal Fusions.
    Melachuri SR; Melachuri MK; Mina A; Anetakis K; Crammond DJ; Balzer JR; Shandal V; Thirumala PD
    World Neurosurg; 2021 Jul; 151():e250-e256. PubMed ID: 33872842
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine: analysis of 2450 consecutively placed screws.
    Parker SL; Amin AG; Farber SH; McGirt MJ; Sciubba DM; Wolinsky JP; Bydon A; Gokaslan ZL; Witham TF
    J Neurosurg Spine; 2011 Aug; 15(2):130-5. PubMed ID: 21529126
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Safe pedicle screw placement in thoracic scoliotic curves using t-EMG: stimulation threshold variability at concavity and convexity in apex segments.
    de Blas G; Barrios C; Regidor I; Montes E; Burgos J; Pizá-Vallespir G; Hevia E
    Spine (Phila Pa 1976); 2012 Mar; 37(6):E387-95. PubMed ID: 22024903
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of t-EMG stimulation of the middle pedicle track to prevent radiculopathies as a result of misplaced lumbar screws.
    Antón-Rodrigálvarez LM; Burgos J; Cabañes L; Mariscal G; Hevia E; Barrios C
    Clin Neurol Neurosurg; 2020 Aug; 195():105915. PubMed ID: 32446117
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of different thresholds for instrumentation device testing in minimally invasive lumbosacral spine fixation.
    Wu Y; Cohen D; Tellez MJ; DiGiacinto GV; Barquero AV; Ulkatan S
    J Clin Neurosci; 2020 Feb; 72():224-228. PubMed ID: 31866354
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition: analysis of 4857 screws.
    Raynor BL; Lenke LG; Bridwell KH; Taylor BA; Padberg AM
    Spine (Phila Pa 1976); 2007 Nov; 32(24):2673-8. PubMed ID: 18007243
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients.
    Ravindra VM; Kalra RR; Dailey AT
    Spine J; 2019 Feb; 19(2):206-211. PubMed ID: 29960110
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement.
    Shi YB; Binette M; Martin WH; Pearson JM; Hart RA
    Spine (Phila Pa 1976); 2003 Mar; 28(6):595-601. PubMed ID: 12642768
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lateral mass screw stimulation thresholds in posterior cervical instrumentation surgery: a predictor of medial deviation.
    Wilson B; Curtis E; Hirshman B; Oygar A; Chen K; Gabel BC; Vaida F; Allison DW; Ciacci JD
    J Neurosurg Spine; 2017 Mar; 26(3):346-352. PubMed ID: 27935447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stimulus-evoked electromyography testing of percutaneous pedicle screws for the detection of pedicle breaches: a clinical study of 409 screws in 93 patients.
    Wang MY; Pineiro G; Mummaneni PV
    J Neurosurg Spine; 2010 Nov; 13(5):600-5. PubMed ID: 21039151
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.
    Malham GM; Parker RM
    J Neurosurg Spine; 2018 Apr; 28(4):357-363. PubMed ID: 29372857
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Can triggered electromyograph thresholds predict safe thoracic pedicle screw placement?
    Raynor BL; Lenke LG; Kim Y; Hanson DS; Wilson-Holden TJ; Bridwell KH; Padberg AM
    Spine (Phila Pa 1976); 2002 Sep; 27(18):2030-5. PubMed ID: 12634564
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of pedicle screw insertion for unilateral open transforaminal lumbar interbody fusion: a side-by-side comparison of percutaneous and conventional open techniques in the same patients.
    Sumiya S; Numano F; Ogawa T; Yoshii T; Okawa A; Komori H
    BMC Musculoskelet Disord; 2020 Mar; 21(1):168. PubMed ID: 32171291
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using triggered electromyographic threshold in the intercostal muscles to evaluate the accuracy of upper thoracic pedicle screw placement (T3-T6).
    Rodriguez-Olaverri JC; Zimick NC; Merola A; De Blas G; Burgos J; Piza-Vallespir G; Hevia E; Vicente J; Sanper I; Domenech P; Regidor I
    Spine (Phila Pa 1976); 2008 Apr; 33(7):E194-7. PubMed ID: 18379388
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stimulus-Evoked Electromyographic Monitoring During Minimally Invasive Transpedicular Implantation of Screws in Lumbosacral Spine: Threshold Value, Methodology and Clinical Effectiveness.
    Wu Y; Vázquez-Barquero A
    World Neurosurg; 2017 Feb; 98():146-151. PubMed ID: 27810457
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A systematic review with meta-analysis of the diagnostic test accuracy of pedicle screw electrical stimulation.
    Fonseca P; Goethel M; Vilas-Boas JP; Gutierres M; Correia MV
    Eur Spine J; 2022 Jul; 31(7):1599-1610. PubMed ID: 35562617
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pedicle screw fixation in thoracolumbar and lumbar spine assisted by lateral fluoroscopic imaging: a study to evaluate the accuracy of screw placement.
    Mohanty SP; Bhat SN; Pai Kanhangad M; Gosal GS
    Musculoskelet Surg; 2018 Apr; 102(1):47-55. PubMed ID: 28801863
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Triggered Electromyography is a Useful Intraoperative Adjunct to Predict Postoperative Neurological Deficit Following Lumbar Pedicle Screw Instrumentation.
    Reddy RP; Chang R; Coutinho DV; Meinert JW; Anetakis KM; Crammond DJ; Balzer JR; Shaw JD; Lee JY; Thirumala PD
    Global Spine J; 2022 Jun; 12(5):1003-1011. PubMed ID: 34013769
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of anode position on pedicle screw testing during lumbosacral spinal fusion surgery.
    Amick M; Ottesen TD; O'Marr J; Frenkel MY; Callahan B; Grauer JN
    Spine J; 2022 Dec; 22(12):2000-2005. PubMed ID: 35843532
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.