These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 33347357)

  • 21. The distal-medial pilot hole: A simple way to ease volar plate positioning in extra-articular distal radius fractures.
    Chelli M; Bronsard N; Gonzalez JF; Blasco L; Gauci MO; Boileau P
    Injury; 2020 Mar; 51(3):779-782. PubMed ID: 32014260
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Towards optimization of volar plate fixations of distal radius fractures: Using finite element analyses to reduce the number of screws.
    Synek A; Baumbach SF; Pahr DH
    Clin Biomech (Bristol, Avon); 2021 Feb; 82():105272. PubMed ID: 33493739
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture.
    Zhang Y; Shao Q; Yang C; Ai C; Zhou D; Yu Y; Sun G
    J Orthop Surg Res; 2021 Mar; 16(1):191. PubMed ID: 33722253
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optimal screw length in volar locking plate osteosynthesis for distal radius fractures: a systematic review.
    Gunaratne R; Nazifi O; D'Souza H; Tay A
    ANZ J Surg; 2022 Apr; 92(4):674-684. PubMed ID: 34825448
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Can we safely place the distal volar locking plate screws into the subchondral zone of a distal radius fracture using a 45° supination oblique view under fluoroscopic guidance?
    Kwon BC; Lee YM; Lee JW; Choi HG
    Injury; 2023 Mar; 54(3):947-953. PubMed ID: 36653250
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical comparison of bicortical locking versus unicortical far-cortex-abutting locking screw-plate fixation for comminuted radial shaft fractures.
    Overturf SJ; Morris RP; Gugala Z; Lindsey RW
    J Hand Surg Am; 2014 Oct; 39(10):1907-13. PubMed ID: 25149898
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture.
    Diong TW; Haflah NHM; Kassim AYM; Habshi SMIA; Shukur MH
    J Hand Surg Asian Pac Vol; 2018 Mar; 23(1):26-32. PubMed ID: 29409409
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical comparison of osteoporotic distal radius fractures fixed by distal locking screws with different length.
    Liu X; Wu WD; Fang YF; Zhang MC; Huang WH
    PLoS One; 2014; 9(7):e103371. PubMed ID: 25080094
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Screw length in volar locking plate fixation for distal radial fractures.
    Yuen G; Yee DK; Fang C; Lau TW; Leung F
    J Orthop Surg (Hong Kong); 2015 Aug; 23(2):164-7. PubMed ID: 26321542
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.
    Heyland M; Duda GN; Haas NP; Trepczynski A; Döbele S; Höntzsch D; Schaser KD; Märdian S
    Injury; 2015 Oct; 46 Suppl 4():S24-32. PubMed ID: 26542863
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Pearls and Pitfalls of the Volar Locking Plating for Distal Radius Fractures.
    Im JH; Lee JY
    J Hand Surg Asian Pac Vol; 2016 Jun; 21(2):125-32. PubMed ID: 27454625
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Multidirectional screw fixation in the treatment of distal radius fractures using angle-stable plates].
    Vlček M; Landor I; Višňa P; Vavřík P; Sindelářová J; Sosna A
    Acta Chir Orthop Traumatol Cech; 2011; 78(1):27-33. PubMed ID: 21375962
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study.
    Kandemir U; Matityahu A; Desai R; Puttlitz C
    J Orthop Trauma; 2008 Oct; 22(9):605-10. PubMed ID: 18827589
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Lift-Off Screw Results in Accurate Sagittal Tilt Correction in a Distal Radius Fracture Model.
    Roebke AJ; Martin AS; Sarmast Z; Fisk E; Goyal KS
    J Hand Surg Am; 2018 Jun; 43(6):523-528. PubMed ID: 29559327
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Stability of volar fixed-angle plating for distal radius fractures. Failure modes in osteoporotic bone].
    Mair S; Weninger P; Högel F; Panzer S; Augat P
    Unfallchirurg; 2013 Apr; 116(4):338-44. PubMed ID: 22072058
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.
    Tsutsui S; Kawasaki K; Yamakoshi K; Uchiyama E; Aoki M; Inagaki K
    J Orthop Sci; 2016 Sep; 21(5):603-8. PubMed ID: 27523260
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Optimal Positioning for Volar Plate Fixation of a Distal Radius Fracture: Determining the Distal Dorsal Cortical Distance.
    Vosbikian MM; Ketonis C; Huang R; Ilyas AM
    Orthop Clin North Am; 2016 Jan; 47(1):235-44. PubMed ID: 26614937
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?
    Abdel-Wahed M; Khater AA; El-Desouky MA
    Int Orthop; 2022 Sep; 46(9):2165-2176. PubMed ID: 35690670
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Finite element analysis of the stability of Mason type Ⅲ radial head fracture fixed with three cross-bridge headless compression screw and locking plate].
    Yin H; Li Y; Zhao G; Xie J; Ning RD; Zhou EC
    Zhongguo Gu Shang; 2024 Jan; 37(1):57-60. PubMed ID: 38286452
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Volar plating in distal radius fractures: A prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration.
    Bergsma M; Doornberg JN; Duit R; Saarig A; Worsley D; Jaarsma R;
    Injury; 2018 Oct; 49(10):1810-1815. PubMed ID: 30017179
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.