195 related articles for article (PubMed ID: 33347403)
1. Combined Ultrasound and Photoacoustic Image Guidance of Spinal Pedicle Cannulation Demonstrated With Intact ex vivo Specimens.
Gonzalez EA; Jain A; Bell MAL
IEEE Trans Biomed Eng; 2021 Aug; 68(8):2479-2489. PubMed ID: 33347403
[TBL] [Abstract][Full Text] [Related]
2. GPU implementation of photoacoustic short-lag spatial coherence imaging for improved image-guided interventions.
Gonzalez EA; Bell MAL
J Biomed Opt; 2020 Jul; 25(7):1-19. PubMed ID: 32713168
[TBL] [Abstract][Full Text] [Related]
3. Simulations and human cadaver head studies to identify optimal acoustic receiver locations for minimally invasive photoacoustic-guided neurosurgery.
Graham MT; Huang J; Creighton FX; Lediju Bell MA
Photoacoustics; 2020 Sep; 19():100183. PubMed ID: 32695578
[TBL] [Abstract][Full Text] [Related]
4. Photoacoustic imaging of a human vertebra: implications for guiding spinal fusion surgeries.
Shubert J; Lediju Bell MA
Phys Med Biol; 2018 Jul; 63(14):144001. PubMed ID: 29923832
[TBL] [Abstract][Full Text] [Related]
5. Accuracy of single-time, multilevel registration in image-guided spinal surgery.
Papadopoulos EC; Girardi FP; Sama A; Sandhu HS; Cammisa FP
Spine J; 2005; 5(3):263-7; discussion 268. PubMed ID: 15863081
[TBL] [Abstract][Full Text] [Related]
6. Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models.
Austin MS; Vaccaro AR; Brislin B; Nachwalter R; Hilibrand AS; Albert TJ
Spine (Phila Pa 1976); 2002 Nov; 27(22):2503-8. PubMed ID: 12435982
[TBL] [Abstract][Full Text] [Related]
7. Pedicle screw placement accuracy using ultra-low radiation imaging with image enhancement versus conventional fluoroscopy in minimally invasive transforaminal lumbar interbody fusion: an internally randomized controlled trial.
Nayar G; Blizzard DJ; Wang TY; Cook S; Back AG; Vincent D; Karikari IO
J Neurosurg Spine; 2018 Feb; 28(2):186-193. PubMed ID: 29192879
[TBL] [Abstract][Full Text] [Related]
8. A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study.
Lu S; Xu YQ; Zhang YZ; Li YB; Xie L; Shi JH; Guo H; Chen GP; Chen YB
Int J Med Robot; 2009 Jun; 5(2):184-91. PubMed ID: 19280584
[TBL] [Abstract][Full Text] [Related]
9. Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws.
Ravi B; Zahrai A; Rampersaud R
Spine (Phila Pa 1976); 2011 Jan; 36(1):84-91. PubMed ID: 20595927
[TBL] [Abstract][Full Text] [Related]
10. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.
Malham GM; Parker RM
J Neurosurg Spine; 2018 Apr; 28(4):357-363. PubMed ID: 29372857
[TBL] [Abstract][Full Text] [Related]
11. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients.
Ravindra VM; Kalra RR; Dailey AT
Spine J; 2019 Feb; 19(2):206-211. PubMed ID: 29960110
[TBL] [Abstract][Full Text] [Related]
12. The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion.
Cho JY; Chan CK; Lee SH; Lee HY
Comput Aided Surg; 2012; 17(6):300-9. PubMed ID: 23098190
[TBL] [Abstract][Full Text] [Related]
13. A keyhole approach for endoscopically assisted pedicle screw fixation in lumbar spine instability.
Müller A; Gall C; März U; Reulen HJ
Neurosurgery; 2000 Jul; 47(1):85-95; discussion 95-6. PubMed ID: 10917351
[TBL] [Abstract][Full Text] [Related]
14. Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds.
Lediju Bell MA; Kuo N; Song DY; Boctor EM
Biomed Opt Express; 2013; 4(10):1964-77. PubMed ID: 24156057
[TBL] [Abstract][Full Text] [Related]
15. Intraosseous ultrasound in the placement of pedicle screws in the lumbar spine.
Kantelhardt SR; Bock CH; Larsen J; Bockermann V; Schillinger W; Rohde V; Giese A
Spine (Phila Pa 1976); 2009 Feb; 34(4):400-7. PubMed ID: 19214101
[TBL] [Abstract][Full Text] [Related]
16. Electromagnetic field-based image-guided spine surgery part one: results of a cadaveric study evaluating lumbar pedicle screw placement.
Sagi HC; Manos R; Benz R; Ordway NR; Connolly PJ
Spine (Phila Pa 1976); 2003 Sep; 28(17):2013-8. PubMed ID: 12973150
[TBL] [Abstract][Full Text] [Related]
17. Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery.
Tormenti MJ; Kostov DB; Gardner PA; Kanter AS; Spiro RM; Okonkwo DO
Neurosurg Focus; 2010 Mar; 28(3):E11. PubMed ID: 20192656
[TBL] [Abstract][Full Text] [Related]
18. Accuracy of percutaneous lumbar pedicle screw placement using the oblique or "owl's-eye" view and novel guidance technology.
Idler C; Rolfe KW; Gorek JE
J Neurosurg Spine; 2010 Oct; 13(4):509-15. PubMed ID: 20887149
[TBL] [Abstract][Full Text] [Related]
19. Single versus separate registration for computer-assisted lumbar pedicle screw placement.
Lee TC; Yang LC; Liliang PC; Su TM; Rau CS; Chen HJ
Spine (Phila Pa 1976); 2004 Jul; 29(14):1585-9. PubMed ID: 15247584
[TBL] [Abstract][Full Text] [Related]
20. Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort.
Nottmeier EW; Seemer W; Young PM
J Neurosurg Spine; 2009 Jan; 10(1):33-9. PubMed ID: 19119930
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]