376 related articles for article (PubMed ID: 33354787)
1. Toward real-time verification for MLC tracking treatments using time-resolved EPID imaging.
Zwan BJ; Caillet V; Booth JT; Colvill E; Fuangrod T; O'Brien R; Briggs A; O'Connor DJ; Keall PJ; Greer PB
Med Phys; 2021 Mar; 48(3):953-964. PubMed ID: 33354787
[TBL] [Abstract][Full Text] [Related]
2. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging.
Zwan BJ; Barnes MP; Hindmarsh J; Lim SB; Lovelock DM; Fuangrod T; O'Connor DJ; Keall PJ; Greer PB
Med Phys; 2017 Aug; 44(8):3909-3922. PubMed ID: 28564208
[TBL] [Abstract][Full Text] [Related]
3. An error detection method for real-time EPID-based treatment delivery quality assurance.
Alves VGL; Ahmed M; Aliotta E; Choi W; Siebers JV
Med Phys; 2021 Feb; 48(2):569-578. PubMed ID: 33314247
[TBL] [Abstract][Full Text] [Related]
4. 4D in vivo dose verification for real-time tumor tracking treatments using EPID dosimetry.
Aftabi S; Sasaki D; VanBeek T; Pistorius S; McCurdy B
Med Dosim; 2021 Spring; 46(1):29-38. PubMed ID: 32778520
[TBL] [Abstract][Full Text] [Related]
5. EPID sensitivity to delivery errors for pre-treatment verification of lung SBRT VMAT plans.
Alharthi T; Arumugam S; Vial P; Holloway L; Thwaites D
Phys Med; 2019 Mar; 59():37-46. PubMed ID: 30928064
[TBL] [Abstract][Full Text] [Related]
6. Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation.
Hirashima H; Miyabe Y; Nakamura M; Mukumoto N; Mizowaki T; Hiraoka M
J Appl Clin Med Phys; 2018 May; 19(3):234-242. PubMed ID: 29633542
[TBL] [Abstract][Full Text] [Related]
7. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.
Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S
Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465
[TBL] [Abstract][Full Text] [Related]
8. Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator.
Hansen R; Ravkilde T; Worm ES; Toftegaard J; Grau C; Macek K; Poulsen PR
Med Phys; 2016 May; 43(5):2387. PubMed ID: 27147350
[TBL] [Abstract][Full Text] [Related]
9. Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods.
Defoor DL; Stathakis S; Roring JE; Kirby NA; Mavroidis P; Obeidat M; Papanikolaou N
J Appl Clin Med Phys; 2017 Jul; 18(4):172-179. PubMed ID: 28585300
[TBL] [Abstract][Full Text] [Related]
10. Sensitivity study of an automated system for daily patient QA using EPID exit dose images.
Zhuang AH; Olch AJ
J Appl Clin Med Phys; 2018 May; 19(3):114-124. PubMed ID: 29508529
[TBL] [Abstract][Full Text] [Related]
11. Fast motion-including dose error reconstruction for VMAT with and without MLC tracking.
Ravkilde T; Keall PJ; Grau C; Høyer M; Poulsen PR
Phys Med Biol; 2014 Dec; 59(23):7279-96. PubMed ID: 25383729
[TBL] [Abstract][Full Text] [Related]
12. A Swiss cheese error detection method for real-time EPID-based quality assurance and error prevention.
Passarge M; Fix MK; Manser P; Stampanoni MF; Siebers JV
Med Phys; 2017 Apr; 44(4):1212-1223. PubMed ID: 28134989
[TBL] [Abstract][Full Text] [Related]
13. Verification of MLC based real-time tumor tracking using an electronic portal imaging device.
Han-Oh S; Yi BY; Lerma F; Berman BL; Gui M; Yu C
Med Phys; 2010 Jun; 37(6):2435-40. PubMed ID: 20632553
[TBL] [Abstract][Full Text] [Related]
14. Real-time high spatial resolution dose verification in stereotactic motion adaptive arc radiotherapy.
Duncan M; Newall MK; Caillet V; Booth JT; Keall PJ; Lerch M; Perevertaylo V; Rosenfeld AB; Petasecca M
J Appl Clin Med Phys; 2018 Jul; 19(4):173-184. PubMed ID: 29873185
[TBL] [Abstract][Full Text] [Related]
15. An EPID-based system for gantry-resolved MLC quality assurance for VMAT.
Zwan BJ; Barnes MP; Fuangord T; Stanton CJ; O'Connor DJ; Keall PJ; Greer PB
J Appl Clin Med Phys; 2016 Sep; 17(5):348-365. PubMed ID: 27685132
[TBL] [Abstract][Full Text] [Related]
16. Couch and multileaf collimator tracking: A clinical feasibility study for pancreas and liver treatment.
Zhang L; LoSasso T; Zhang P; Hunt M; Mageras G; Tang G
Med Phys; 2020 Oct; 47(10):4743-4757. PubMed ID: 32757298
[TBL] [Abstract][Full Text] [Related]
17. Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries.
McCowan PM; McCurdy BM
Med Phys; 2016 Jan; 43(1):254. PubMed ID: 26745918
[TBL] [Abstract][Full Text] [Related]
18. An independent system for real-time dynamic multileaf collimation trajectory verification using EPID.
Fuangrod T; Woodruff HC; Rowshanfarzad P; O'Connor DJ; Middleton RH; Greer PB
Phys Med Biol; 2014 Jan; 59(1):61-81. PubMed ID: 24334552
[TBL] [Abstract][Full Text] [Related]
19. Time-resolved dose distributions to moving targets during volumetric modulated arc therapy with and without dynamic MLC tracking.
Ravkilde T; Keall PJ; Grau C; Høyer M; Poulsen PR
Med Phys; 2013 Nov; 40(11):111723. PubMed ID: 24320431
[TBL] [Abstract][Full Text] [Related]
20. A novel method for sub-arc VMAT dose delivery verification based on portal dosimetry with an EPID.
Cools RAM; Dirkx MLP; Heijmen BJM
Med Phys; 2017 Nov; 44(11):5556-5562. PubMed ID: 28815696
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]