These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
331 related articles for article (PubMed ID: 33358079)
1. Evaluation of Antegrade Intramedullary Compression Screw Fixation of Metacarpal Shaft Fractures in a Cadaver Model. Hoang D; Vu CL; Huang JI J Hand Surg Am; 2021 May; 46(5):428.e1-428.e7. PubMed ID: 33358079 [TBL] [Abstract][Full Text] [Related]
2. An Anatomical Study of Metacarpal Morphology Utilizing CT Scans: Evaluating Parameters for Antegrade Intramedullary Compression Screw Fixation of Metacarpal Fractures. Hoang D; Vu CL; Jackson M; Huang JI J Hand Surg Am; 2021 Feb; 46(2):149.e1-149.e8. PubMed ID: 33092908 [TBL] [Abstract][Full Text] [Related]
3. Effect of oblique headless compression screw fixation for metacarpal shaft fracture: a biomechanical in vitro study. Chiu YC; Ho TY; Ting YN; Tsai MT; Huang HL; Hsu CE; Hsu JT BMC Musculoskelet Disord; 2021 Feb; 22(1):146. PubMed ID: 33546670 [TBL] [Abstract][Full Text] [Related]
4. Articular Involvement With Retrograde Headless Compression Screw Fixation of the Metacarpal. Straszewski AJ; Dickherber JL; Conti Mica MA J Hand Surg Am; 2024 Jan; 49(1):62.e1-62.e6. PubMed ID: 35868900 [TBL] [Abstract][Full Text] [Related]
5. Metacarpal shaft fixation: a biomechanical comparison of dorsal plating, lag screws, and headless compression screws. Dyrna FGE; Avery DM; Yoshida R; Lam D; Oeckenpöhler S; Cote MP; Obopilwe E; Rodner CM; Mazzocca AD BMC Musculoskelet Disord; 2021 Apr; 22(1):335. PubMed ID: 33827523 [TBL] [Abstract][Full Text] [Related]
6. Quantitative 3-dimensional CT analyses of intramedullary headless screw fixation for metacarpal neck fractures. ten Berg PW; Mudgal CS; Leibman MI; Belsky MR; Ruchelsman DE J Hand Surg Am; 2013 Feb; 38(2):322-330.e2. PubMed ID: 23200214 [TBL] [Abstract][Full Text] [Related]
7. Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study. Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I Rev Esp Cir Ortop Traumatol; 2023; 67(1):50-55. PubMed ID: 35709951 [TBL] [Abstract][Full Text] [Related]
8. [Translated article] Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study. Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I Rev Esp Cir Ortop Traumatol; 2023; 67(1):T50-T55. PubMed ID: 36243394 [TBL] [Abstract][Full Text] [Related]
9. Minimally Invasive Intramedullary Screw Versus Plate Fixation for Proximal Phalanx Fractures: A Biomechanical Study. Miles MR; Krul KP; Abbasi P; Thakkar MY; Giladi AM; Means KR J Hand Surg Am; 2021 Jun; 46(6):518.e1-518.e8. PubMed ID: 33423850 [TBL] [Abstract][Full Text] [Related]
10. Cartilage and extensor tendon defects after headless compression screw fixation of phalangeal and metacarpal fractures. Urbanschitz L; Dreu M; Wagner J; Kaufmann R; Jeserschek JM; Borbas P J Hand Surg Eur Vol; 2020 Jul; 45(6):601-607. PubMed ID: 32370585 [TBL] [Abstract][Full Text] [Related]
11. Intramedullary Headless Screw Fixation of Metacarpal Fractures: A Radiographic Analysis for Optimal Screw Choice. Okoli M; Chatterji R; Ilyas A; Kirkpatrick W; Abboudi J; Jones CM Hand (N Y); 2022 Mar; 17(2):245-253. PubMed ID: 32432499 [No Abstract] [Full Text] [Related]
13. A Comparative Study of Tensile Strength of Three Operative Fixation Techniques for Metacarpal Shaft Fractures in Adults: A Cadaver Study. Oh JR; Kim DS; Yeom JS; Kang SK; Kim YT Clin Orthop Surg; 2019 Mar; 11(1):120-125. PubMed ID: 30838116 [TBL] [Abstract][Full Text] [Related]
15. Modified retrograde percutaneous intramedullary multiple Kirschner wire fixation for treatment of unstable displaced metacarpal neck and shaft fractures. Lee SK; Kim KJ; Choy WS Eur J Orthop Surg Traumatol; 2013 Jul; 23(5):535-43. PubMed ID: 23412169 [TBL] [Abstract][Full Text] [Related]
16. Headless Compression Screw Versus Kirschner Wire Fixation for Metacarpal Neck Fractures: A Biomechanical Study. Avery DM; Klinge S; Dyrna F; Pauzenberger L; Lam D; Cote M; DiVenere J; Obopilwe E; Mazzocca A; Rodner C J Hand Surg Am; 2017 May; 42(5):392.e1-392.e6. PubMed ID: 28359640 [TBL] [Abstract][Full Text] [Related]
17. Intramedullary screw fixation for metacarpal shaft fractures: a biomechanical human cadaver study. Labèr R; Jann D; Behm P; Ferguson SJ; Frueh FS; Calcagni M J Hand Surg Eur Vol; 2020 Jul; 45(6):595-600. PubMed ID: 31948331 [TBL] [Abstract][Full Text] [Related]
18. Three-Dimensional Analysis of Metacarpal Head Articular Defects Created by Headless Screws. Bachoura A; Gaspar M; Kane P; Bernstein D; Rekant MS; Osterman AL Arch Bone Jt Surg; 2023; 11(11):684-689. PubMed ID: 38058972 [TBL] [Abstract][Full Text] [Related]
19. Retrograde intramedullary headless compression screws for treatment of extra-articular thumb metacarpal base fractures. Barrera-Ochoa S; Alabau-Rodriguez S; Campillo-Recio D; Esteban-Feliu I; Mir-Bullo X; Soldado F J Hand Surg Eur Vol; 2020 Jul; 45(6):588-594. PubMed ID: 32397785 [TBL] [Abstract][Full Text] [Related]
20. Low Rate of Complications Following Intramedullary Headless Compression Screw Fixation of Metacarpal Fractures. Warrender WJ; Ruchelsman DE; Livesey MG; Mudgal CS; Rivlin M Hand (N Y); 2020 Nov; 15(6):798-804. PubMed ID: 30894028 [No Abstract] [Full Text] [Related] [Next] [New Search]