126 related articles for article (PubMed ID: 33358142)
1. Comparison of TG43 and Hounsfield Unit-based TG186 brachytherapy dose metrics in Oncentra Brachy for 100 patients receiving interstitial partial breast irradiation.
Howie A; Poder J; Brown R; Schreiber K; Bece A; Graham P; Chin YS
Brachytherapy; 2021; 20(3):655-663. PubMed ID: 33358142
[TBL] [Abstract][Full Text] [Related]
2. A retrospective dosimetric comparison of TG43 and a commercially available MBDCA for an APBI brachytherapy patient cohort.
Zourari K; Major T; Herein A; Peppa V; Polgár C; Papagiannis P
Phys Med; 2015 Nov; 31(7):669-76. PubMed ID: 26055951
[TBL] [Abstract][Full Text] [Related]
3. Performance evaluation of a collapsed cone dose calculation algorithm for HDR Ir-192 of APBI treatments.
Terribilini D; Vitzthum V; Volken W; Frei D; Loessl K; van Veelen B; Manser P; Fix MK
Med Phys; 2017 Oct; 44(10):5475-5485. PubMed ID: 28750134
[TBL] [Abstract][Full Text] [Related]
4. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
[TBL] [Abstract][Full Text] [Related]
5. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of a collapsed-cone convolution algorithm for esophagus and surface mold
Eason L; Mason J; Cooper R; Radhakrishna G; Bownes P
Brachytherapy; 2021; 20(2):393-400. PubMed ID: 33071170
[TBL] [Abstract][Full Text] [Related]
7. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation.
Beaulieu L; Carlsson Tedgren A; Carrier JF; Davis SD; Mourtada F; Rivard MJ; Thomson RM; Verhaegen F; Wareing TA; Williamson JF
Med Phys; 2012 Oct; 39(10):6208-36. PubMed ID: 23039658
[TBL] [Abstract][Full Text] [Related]
8. Validation of the collapsed cone algorithm for HDR liver brachytherapy against Monte Carlo simulations.
Duque AS; van Wagenberg T; Seidensticker M; Streitparth F; Walter F; Parodi K; Verhaegen F; Ricke J; Belka C; Paiva Fonseca G; Corradini S; Landry G
Brachytherapy; 2021; 20(4):936-947. PubMed ID: 34001415
[TBL] [Abstract][Full Text] [Related]
9. BrachyGuide: a brachytherapy-dedicated DICOM RT viewer and interface to Monte Carlo simulation software.
Pantelis E; Peppa V; Lahanas V; Pappas E; Papagiannis P
J Appl Clin Med Phys; 2015 Jan; 16(1):5136. PubMed ID: 25679171
[TBL] [Abstract][Full Text] [Related]
10. The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy.
Duque AS; Corradini S; Kamp F; Seidensticker M; Streitparth F; Kurz C; Walter F; Parodi K; Verhaegen F; Ricke J; Belka C; Fonseca GP; Landry G
Radiat Oncol; 2020 Mar; 15(1):60. PubMed ID: 32151255
[TBL] [Abstract][Full Text] [Related]
11. A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy.
Yousif YAM; Osman AFI; Halato MA
Phys Eng Sci Med; 2021 Sep; 44(3):871-886. PubMed ID: 34142317
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric and radiobiological investigation of permanent implant prostate brachytherapy based on Monte Carlo calculations.
Haidari AM; Miksys N; Soubiran P; Cygler JE; Holmes O; Perry G; Thomson RM
Brachytherapy; 2019; 18(6):875-882. PubMed ID: 31400953
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric and radiobiological comparison of TG-43 and Monte Carlo calculations in
Peppa V; Pappas EP; Karaiskos P; Major T; Polgár C; Papagiannis P
Phys Med; 2016 Oct; 32(10):1245-1251. PubMed ID: 27720277
[TBL] [Abstract][Full Text] [Related]
14. Validation of the Oncentra Brachy Advanced Collapsed cone Engine for a commercial (192)Ir source using heterogeneous geometries.
Ma Y; Lacroix F; Lavallée MC; Beaulieu L
Brachytherapy; 2015; 14(6):939-52. PubMed ID: 26403533
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric accuracy of a deterministic radiation transport based (192)Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models.
Zourari K; Pantelis E; Moutsatsos A; Sakelliou L; Georgiou E; Karaiskos P; Papagiannis P
Med Phys; 2013 Jan; 40(1):011712. PubMed ID: 23298082
[TBL] [Abstract][Full Text] [Related]
16. Modeling of the direction modulated brachytherapy tandem applicator using the Oncentra Brachy advanced collapsed cone engine.
Safigholi H; van Veelen B; Niatsetski Y; Song WY
Brachytherapy; 2018; 17(6):1030-1036. PubMed ID: 30181054
[TBL] [Abstract][Full Text] [Related]
17. AAPM WGDCAB Report 372: A joint AAPM, ESTRO, ABG, and ABS report on commissioning of model-based dose calculation algorithms in brachytherapy.
Beaulieu L; Ballester F; Granero D; Tedgren ÅC; Haworth A; Lowenstein JR; Ma Y; Mourtada F; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Fonseca G; Vijande J
Med Phys; 2023 Aug; 50(8):e946-e960. PubMed ID: 37427750
[TBL] [Abstract][Full Text] [Related]
18. A MC-based anthropomorphic test case for commissioning model-based dose calculation in interstitial breast 192-Ir HDR brachytherapy.
Peppa V; Thomson RM; Enger SA; Fonseca GP; Lee C; Lucero JNE; Mourtada F; Siebert FA; Vijande J; Papagiannis P
Med Phys; 2023 Jul; 50(7):4675-4687. PubMed ID: 37194638
[TBL] [Abstract][Full Text] [Related]
19. egs_brachy: a versatile and fast Monte Carlo code for brachytherapy.
Chamberland MJ; Taylor RE; Rogers DW; Thomson RM
Phys Med Biol; 2016 Dec; 61(23):8214-8231. PubMed ID: 27804922
[TBL] [Abstract][Full Text] [Related]
20. A user-oriented procedure for the commissioning and quality assurance testing of treatment planning system dosimetry in high-dose-rate brachytherapy.
Peppa V; Pantelis E; Pappas E; Lahanas V; Loukas C; Papagiannis P
Brachytherapy; 2016; 15(2):252-62. PubMed ID: 26727331
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]