BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 33364205)

  • 1. Study of Photoneutron Production for the 18 MV Photon Beam of the Siemens Medical linac by Monte Carlo Simulation.
    H D; A A M; M G; S M; C K
    J Biomed Phys Eng; 2020 Dec; 10(6):679-690. PubMed ID: 33364205
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator.
    Montgomery L; Evans M; Liang L; Maglieri R; Kildea J
    Med Phys; 2018 Oct; 45(10):4711-4719. PubMed ID: 30141186
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The impact of automatic wedge filter on photoneutron and photon spectra of an 18-MV photon beam.
    Ghavami SM; Mesbahi A; Mohammadi E
    Radiat Prot Dosimetry; 2010 Feb; 138(2):123-8. PubMed ID: 19789200
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O; Ma CM
    Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam.
    Mesbahi A
    Appl Radiat Isot; 2009 Jan; 67(1):55-60. PubMed ID: 18760613
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study.
    Talebi AS; Maleki M; Hejazi P; Jadidi M; Ghorbani R
    J Biomed Phys Eng; 2018 Sep; 8(3):231-240. PubMed ID: 30320027
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of each component of a LINAC therapy head on neutron and photon spectra.
    Khabaz R
    Appl Radiat Isot; 2018 Sep; 139():40-45. PubMed ID: 29704704
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo study of Siemens PRIMUS photoneutron production.
    Pena J; Franco L; Gómez F; Iglesias A; Pardo J; Pombar M
    Phys Med Biol; 2005 Dec; 50(24):5921-33. PubMed ID: 16333164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Feasibility of 18-MV grid therapy from radiation protection aspects: unwanted dose and fatal cancer risk caused by photoneutrons and scattered photons.
    Karimi AH; Mirian SF; Mahmoudi F; Geraily G; Vega-Carrillo HR; Mohiuddin M
    Comput Methods Programs Biomed; 2022 Jan; 213():106524. PubMed ID: 34818621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of tertiary MLC configuration on secondary neutron spectra from 18 MV x-ray beams for the Varian 21EX linear accelerator.
    Howell RM; Kry SF; Burgett E; Followill D; Hertel NE
    Med Phys; 2009 Sep; 36(9):4039-46. PubMed ID: 19810476
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photoneutron production of a Siemens Primus linear accelerator studied by Monte Carlo methods and a paired magnesium and boron coated magnesium ionization chamber system.
    Becker J; Brunckhorst E; Schmidt R
    Phys Med Biol; 2007 Nov; 52(21):6375-87. PubMed ID: 17951849
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac.
    Bahreyni Toossi MT; Behmadi M; Ghorbani M; Gholamhosseinian H
    J Appl Clin Med Phys; 2013 Sep; 14(5):52-67. PubMed ID: 24036859
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of photoneutron dose equivalent in 10 MV and 15 MV beams for wedge and open fields in the Elekta Versa HD linac.
    Khilafath HRAS; Ganesan B; Sekar N; Mohapatra D; Mahadevan P; Vellingiri J; Prakasarao A; Singaravelu G
    Appl Radiat Isot; 2022 Oct; 188():110363. PubMed ID: 35863145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. TOPAS simulation of photoneutrons in radiotherapy: accuracy and speed with variance reduction.
    Ramos-Mendez J; Ortiz CR; Schuemann J; Paganetti H; Faddegon B
    Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38657630
    [No Abstract]   [Full Text] [Related]  

  • 15. Evaluation of the linac neutron dose profile for various depths and field sizes: a Monte Carlo study.
    Prasada DNY; Ciamaudi N; Fadli M; Tursinah R; Pawiro SA
    Biomed Phys Eng Express; 2021 Oct; 7(6):. PubMed ID: 34619664
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams.
    Dowlatabadi H; Mowlavi AA; Ghorbani M
    J Biomed Phys Eng; 2017 Dec; 7(4):333-346. PubMed ID: 29616199
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the effectiveness of steel for shielding photoneutrons produced in medical linear accelerators: A Monte Carlo particle transport study.
    Moghaddasi L; Colyer C
    Phys Med; 2022 Jun; 98():53-62. PubMed ID: 35490530
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.
    Nedaie HA; Darestani H; Banaee N; Shagholi N; Mohammadi K; Shahvar A; Bayat E
    J Med Phys; 2014 Jan; 39(1):10-7. PubMed ID: 24600167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the photoneutron field produced in a medical linear accelerator.
    Kim HS; Park YH; Koo BC; Kwon JW; Lee JS; Choi HS
    Radiat Prot Dosimetry; 2007; 123(3):323-8. PubMed ID: 17077093
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.