These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 33368061)

  • 1. Comparison between Single- and Multi-Radius Prostheses Used in Modified Kinematically Aligned Cruciate-Retaining Total Knee Arthroplasty.
    Matsumoto T; Takashima Y; Takayama K; Ishida K; Nakano N; Kuroda Y; Tsubosaka M; Kamenaga T; Matsushita T; Niikura T; Hayashi S; Kuroda R
    J Knee Surg; 2022 Jul; 35(9):1004-1009. PubMed ID: 33368061
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Effect of Prosthesis Type on Intraoperative Soft-Tissue Balance and Clinical Outcomes in Modified Kinematically Aligned Cruciate-Retaining Total Knee Arthroplasty.
    Matsumoto T; Nakano N; Ishida K; Takashima Y; Maeda T; Kuroda Y; Hayashi S; Matsushita T; Niikura T; Muratsu H; Kuroda R
    J Knee Surg; 2023 Aug; 36(10):1013-1019. PubMed ID: 35817057
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of Femoral Component Design on the Deepest Point Position of the Trochlear Grove in Kinematically Aligned Total Knee Arthroplasty: A Comparison of Four Prothesis Designs.
    Takashima Y; Nakano N; Ishida K; Kamenaga T; Tsubosaka M; Kuroda Y; Hayashi S; Kuroda R; Matsumoto T
    J Knee Surg; 2023 Nov; 36(13):1316-1322. PubMed ID: 36150661
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative Soft Tissue Balance/Kinematics and Clinical Evaluation of Modified Kinematically versus Mechanically Aligned Total Knee Arthroplasty.
    Matsumoto T; Takayama K; Ishida K; Kuroda Y; Tsubosaka M; Muratsu H; Hayashi S; Hashimoto S; Matsushita T; Niikura T; Kuroda R
    J Knee Surg; 2020 Aug; 33(8):777-784. PubMed ID: 31067590
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiographic evaluation of patellofemoral alignment in kinematically aligned total knee arthroplasty: A comparative study with mechanically aligned total knee arthroplasty.
    Nagai K; Niki Y; Kobayashi S; Harato K; Nagura T; Matsumoto M; Nakamura M
    J Orthop Sci; 2021 Nov; 26(6):1043-1050. PubMed ID: 33183938
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Kinematic alignment in total knee arthroplasty leads to a better restoration of patellar kinematics compared to mechanic alignment.
    Keshmiri A; Maderbacher G; Baier C; Benditz A; Grifka J; Greimel F
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1529-1534. PubMed ID: 30421165
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Kinematic alignment of current TKA implants does not restore the native trochlear anatomy.
    Rivière C; Dhaif F; Shah H; Ali A; Auvinet E; Aframian A; Cobb J; Howell S; Harris S
    Orthop Traumatol Surg Res; 2018 Nov; 104(7):983-995. PubMed ID: 29960090
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Differences in trochlear parameters between native and prosthetic kinematically or mechanically aligned knees.
    Rivière C; Iranpour F; Harris S; Auvinet E; Aframian A; Parratte S; Cobb J
    Orthop Traumatol Surg Res; 2018 Apr; 104(2):165-170. PubMed ID: 29223778
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Do varus or valgus outliers have higher forces in the medial or lateral compartments than those which are in-range after a kinematically aligned total knee arthroplasty? limb and joint line alignment after kinematically aligned total knee arthroplasty.
    Shelton TJ; Nedopil AJ; Howell SM; Hull ML
    Bone Joint J; 2017 Oct; 99-B(10):1319-1328. PubMed ID: 28963153
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the Radiologic, Morphometric, and Clinical Outcomes between Kinematically and Mechanically Aligned Total Knee Arthroplasty: A Propensity Matching Study.
    Kim TW; Lee JI; Choi HG; Yoo HJ; Kim KT; Lee YS
    J Knee Surg; 2022 Nov; 35(13):1453-1461. PubMed ID: 33657622
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion.
    Koh IJ; Park IJ; Lin CC; Patel NA; Chalmers CE; Maniglio M; McGarry MH; Lee TQ
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1520-1528. PubMed ID: 30370439
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Kinematically aligned total knee arthroplasty limits high tibial forces, differences in tibial forces between compartments, and abnormal tibial contact kinematics during passive flexion.
    Roth JD; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1589-1601. PubMed ID: 28884312
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design.
    Ishikawa M; Kuriyama S; Ito H; Furu M; Nakamura S; Matsuda S
    Knee; 2015 Jun; 22(3):206-12. PubMed ID: 25813759
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiological and clinical comparison of kinematically
    Matsumoto T; Takayama K; Ishida K; Hayashi S; Hashimoto S; Kuroda R
    Bone Joint J; 2017 May; 99-B(5):640-646. PubMed ID: 28455473
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty.
    Niki Y; Nagura T; Nagai K; Kobayashi S; Harato K
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1629-1635. PubMed ID: 29204861
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Kinematic alignment in total knee arthroplasty better reproduces normal gait than mechanical alignment.
    Blakeney W; Clément J; Desmeules F; Hagemeister N; Rivière C; Vendittoli PA
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1410-1417. PubMed ID: 30276435
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Variability in static alignment and kinematics for kinematically aligned TKA.
    Theodore W; Twiggs J; Kolos E; Roe J; Fritsch B; Dickison D; Liu D; Salmon L; Miles B; Howell S
    Knee; 2017 Aug; 24(4):733-744. PubMed ID: 28571921
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Kinematically aligned TKA can align knee joint line to horizontal.
    Ji HM; Han J; Jin DS; Seo H; Won YY
    Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2436-41. PubMed ID: 26811035
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A cruciate-retaining implant can treat both knees of most windswept deformities when performed with calipered kinematically aligned TKA.
    Howell SM; Shelton TJ; Gill M; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2021 Feb; 29(2):437-445. PubMed ID: 32239272
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Randomized Controlled Trial of Kinematically and Mechanically Aligned Total Knee Arthroplasties: Long-Term Follow-Up.
    Dossett HG; Arthur JR; Makovicka JL; Mara KC; Bingham JS; Clarke HD; Spangehl MJ
    J Arthroplasty; 2023 Jun; 38(6S):S209-S214. PubMed ID: 37003458
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.