169 related articles for article (PubMed ID: 33371141)
1. Can bioimpedance cardiography assess hemodynamic response to passive leg raising in critically ill patients: A STROBE-compliant study.
Li L; Ai Y; Huang L; Ai M; Peng Q; Zhang L
Medicine (Baltimore); 2020 Dec; 99(51):e23764. PubMed ID: 33371141
[TBL] [Abstract][Full Text] [Related]
2. Do ScvO
Giraud R; Vujovic B; Assouline B; Neto Silva I; Bendjelid K
Physiol Rep; 2021 Sep; 9(17):e15012. PubMed ID: 34491003
[TBL] [Abstract][Full Text] [Related]
3. [The value of passive leg raising test in predicting fluid responsiveness in patients with sepsis-induced cardiac dysfunction].
Xiang S; Muyun H; Juan C; Bin O; Minying C; Changjie C; Jianfeng W; Zimeng L; Yongjun L; Shunwei H; Lifen L; Xiangdong G
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2015 Sep; 27(9):729-34. PubMed ID: 26955698
[TBL] [Abstract][Full Text] [Related]
4. Correlation of Common Carotid Artery Blood Flow Parameters With Transthoracic Echocardiographic Cardiac Output for Assessing Fluid Responsiveness After Passive Leg Raising (PLR) Test in Critically Ill Patients.
Patnaik R; Krishna B; Sampath S
Cureus; 2023 Jun; 15(6):e40229. PubMed ID: 37435241
[TBL] [Abstract][Full Text] [Related]
5. [Clinical observation of passive leg raising combined with non invasive cardiac output monitoring system in predicting volume responsiveness].
Wang HL; Liu HT; Yu KJ
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2011 Mar; 23(3):146-9. PubMed ID: 21366942
[TBL] [Abstract][Full Text] [Related]
6. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient.
Mercado P; Maizel J; Beyls C; Titeca-Beauport D; Joris M; Kontar L; Riviere A; Bonef O; Soupison T; Tribouilloy C; de Cagny B; Slama M
Crit Care; 2017 Jun; 21(1):136. PubMed ID: 28595621
[TBL] [Abstract][Full Text] [Related]
7. Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo/FloTrac device.
Biais M; Vidil L; Sarrabay P; Cottenceau V; Revel P; Sztark F
Crit Care; 2009; 13(6):R195. PubMed ID: 19968880
[TBL] [Abstract][Full Text] [Related]
8. The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients.
Marik PE; Levitov A; Young A; Andrews L
Chest; 2013 Feb; 143(2):364-370. PubMed ID: 22910834
[TBL] [Abstract][Full Text] [Related]
9. Effect of Systolic Cardiac Function on Passive Leg Raising for Predicting Fluid Responsiveness: A Prospective Observational Study.
Si X; Cao DY; Chen J; Wu JF; Liu ZM; Xu HL; Chen MY; Liu YJ; Guan XD
Chin Med J (Engl); 2018 Feb; 131(3):253-261. PubMed ID: 29363638
[TBL] [Abstract][Full Text] [Related]
10. Passive leg raising test to predict fluid responsiveness using the right ventricle outflow tract velocity-time integral through a subcostal view.
Cheong I; Otero Castro V; Brizuela M; Früchtenicht MF; Merlo PM; Tamagnone FM
J Ultrasound; 2022 Sep; ():. PubMed ID: 36127570
[TBL] [Abstract][Full Text] [Related]
11. Can passive leg raise predict the response to fluid resuscitation in ED?
Elwan MH; Roshdy A; Elsharkawy EM; Eltahan SM; Coats TJ
BMC Emerg Med; 2022 Oct; 22(1):172. PubMed ID: 36289475
[TBL] [Abstract][Full Text] [Related]
12. Monitoring Changes in Hepatic Venous Velocities Flow after a Fluid Challenge Can Identify Shock Patients Who Lack Fluid Responsiveness.
Du W; Wang XT; Long Y; Liu DW
Chin Med J (Engl); 2017 May; 130(10):1202-1210. PubMed ID: 28485321
[TBL] [Abstract][Full Text] [Related]
13. [Evaluation of volume overload in critical patients by monitoring change of cardiac output under bed head raising combined with passive leg raising].
Zhang L; Wang L; Luo W; Mei M; Chen Y; Ouyang B
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2017 Aug; 29(8):711-715. PubMed ID: 28795669
[TBL] [Abstract][Full Text] [Related]
14. Changes in pulse pressure variation to assess preload responsiveness in mechanically ventilated patients with spontaneous breathing activity: an observational study.
Hamzaoui O; Shi R; Carelli S; Sztrymf B; Prat D; Jacobs F; Monnet X; Gouëzel C; Teboul JL
Br J Anaesth; 2021 Oct; 127(4):532-538. PubMed ID: 34246460
[TBL] [Abstract][Full Text] [Related]
15. [The prediction value of noninvasive bioreactance-based passive leg raising test in assessing fluid responsiveness in elderly patients with sepsis].
Tong H; Hu C; Hao X; Cai G; Rao Q; Yan M; Chen J; Yan J
Zhonghua Nei Ke Za Zhi; 2015 Feb; 54(2):130-3. PubMed ID: 25907844
[TBL] [Abstract][Full Text] [Related]
16. Accuracy assessment of noninvasive cardiac output monitoring in the hemodynamic monitoring in critically ill patients.
Zhu G; Zhang K; Fu Y; Hu Z
Ann Palliat Med; 2020 Sep; 9(5):3506-3512. PubMed ID: 33065801
[TBL] [Abstract][Full Text] [Related]
17. Passive leg raising test using the carotid flow velocity-time integral to predict fluid responsiveness.
Cheong I; Otero Castro V; Sosa FA; Tort Oribe B; Früchtenicht MF; Tamagnone FM; Merlo PM
J Ultrasound; 2024 Mar; 27(1):97-104. PubMed ID: 37668901
[TBL] [Abstract][Full Text] [Related]
18. The Accuracy of Velocity-Time Integral Variation and Peak Velocity Variation of the Left Ventricular Outflow Tract in Predicting Fluid Responsiveness in Postoperative Patients Mechanically Ventilated at Low Tidal Volumes.
Xie J; Wan J; Xu L; Zhang Y; Chen J
J Cardiothorac Vasc Anesth; 2023 Jun; 37(6):911-918. PubMed ID: 36931906
[TBL] [Abstract][Full Text] [Related]
19. [Clinical observation of non-invasive ultrasonic cardiac output monitor combined passive leg raising test in predicting the children volume responsiveness].
Wu Y; Liu X; Li C; He Y; Yang W; Yang Y; Ma W; Fu K
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2014 Jan; 26(1):46-50. PubMed ID: 24506855
[TBL] [Abstract][Full Text] [Related]
20. Ultrasound stroke volume variation induced by passive leg raising and fluid responsiveness: An observational cohort study.
Trifi A; Abdellatif S; Daly F; Nasri R; Touil Y; Ben Lakhal S
Med Intensiva (Engl Ed); 2019; 43(1):10-17. PubMed ID: 29258779
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]