These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 33373045)

  • 1. Predictors of permanent pacemaker implantation after ACURATE neo transcatheter heart valve implantation.
    Kim WK; Möllmann H; Walther T; Hamm CW
    Pacing Clin Electrophysiol; 2021 Feb; 44(2):410-415. PubMed ID: 33373045
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Risk Assessment of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation in Patients With Preexisting Right Bundle Branch Block.
    Sugiyama Y; Miyashita H; Yokoyama H; Ochiai T; Shishido K; Jalanko M; Yamanaka F; Vähäsilta T; Saito S; Laine M; Moriyama N
    Am J Cardiol; 2024 Feb; 213():151-160. PubMed ID: 38103766
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter Valve SELECTion in Patients With Right Bundle Branch Block and Impact on Pacemaker Implantations.
    Husser O; Pellegrini C; Kim WK; Holzamer A; Pilgrim T; Toggweiler S; Schäfer U; Blumenstein J; Deuschl F; Rheude T; Joner M; Hilker M; Hengstenberg C; Möllmann H
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1781-1793. PubMed ID: 31537278
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictors of pacemaker implantation after transcatheter aortic valve implantation according to kind of prosthesis and risk profile: a systematic review and contemporary meta-analysis.
    Bruno F; D'Ascenzo F; Vaira MP; Elia E; Omedè P; Kodali S; Barbanti M; Rodès-Cabau J; Husser O; Sossalla S; Van Mieghem NM; Bax J; Hildick-Smith D; Munoz-Garcia A; Pollari F; Fischlein T; Budano C; Montefusco A; Gallone G; De Filippo O; Rinaldi M; la Torre M; Salizzoni S; Atzeni F; Pocar M; Conrotto F; De Ferrari GM
    Eur Heart J Qual Care Clin Outcomes; 2021 Mar; 7(2):143-153. PubMed ID: 33289527
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R.
    Kaneko H; Hoelschermann F; Seifert M; Tambor G; Okamoto M; Moeller V; Neuss M; Butter C
    Heart Vessels; 2019 Feb; 34(2):360-367. PubMed ID: 30083944
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predictors of Need for Permanent Pacemaker Implantation and Conduction Abnormalities With a Novel Self-expanding Transcatheter Heart Valve.
    Pellegrini C; Husser O; Kim WK; Holzamer A; Walther T; Rheude T; Mayr NP; Trenkwalder T; Joner M; Michel J; Chaustre F; Kastrati A; Schunkert H; Burgdorf C; Hilker M; Möllmann H; Hengstenberg C
    Rev Esp Cardiol (Engl Ed); 2019 Feb; 72(2):145-153. PubMed ID: 29551701
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Incidence, predictors, and clinical outcomes of permanent pacemaker insertion following transcatheter aortic valve implantation in an Arab population.
    Rajah FT; Alaamiri AA; Mahmoodurrahman M; Alhowaish TS; Aldosari SF; Hussain AO; Masuadi EM; Arifi AA; Balgaith MA; Ayoub KM; Almutairi FQ; Alanazi HA
    J Interv Card Electrophysiol; 2022 Apr; 63(3):545-554. PubMed ID: 34427830
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve.
    Gonska B; Seeger J; Keßler M; von Keil A; Rottbauer W; Wöhrle J
    Clin Res Cardiol; 2017 Aug; 106(8):590-597. PubMed ID: 28283746
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: The INTERSECT registry.
    Hokken TW; Muhemin M; Okuno T; Veulemans V; Lopes BB; Beneduce A; Vittorio R; Ooms JF; Adrichem R; Neleman T; Kardys I; Daemen J; Chieffo A; Montorfano M; Cavalcante J; Zeus T; Pilgrim T; Toggweiler S; Van Mieghem NM
    J Cardiovasc Comput Tomogr; 2022; 16(6):524-530. PubMed ID: 35872136
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Permanent pacemaker implantation following transcatheter aortic valve implantation using self-expandable, balloon-expandable, or mechanically expandable devices: a network meta-analysis.
    Ravaux JM; Di Mauro M; Vernooy K; Kats S; Mariani S; Ronco D; Actis Dato G; Simons J; Hof AWV; Maessen JG; Lorusso R
    Europace; 2021 Dec; 23(12):1998-2009. PubMed ID: 34379760
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Anatomical Annulus Predictors of New Permanent Pacemaker Implantation Risk After Balloon-Expandable Transcatheter Aortic Valve Implantation.
    Bianchini F; Bianchini E; Romagnoli E; Aurigemma C; Zito A; Busco M; Nesta M; Bruno P; Laezza D; Giambusso N; Natale L; Pelargonio G; Burzotta F; Trani C
    Am J Cardiol; 2024 Aug; 224():26-35. PubMed ID: 38844197
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis.
    Droppa M; Rudolph TK; Baan J; Nielsen NE; Baumgartner H; Vendrik J; Froehlich M; Borst O; Wöhrle J; Gawaz M; Potratz P; Hack LP; Mauri V; Baranowski J; Bramlage P; Kurucova J; Thoenes M; Rottbauer W; Geisler T
    Heart Vessels; 2020 Dec; 35(12):1735-1745. PubMed ID: 32591894
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Self-Expanding Bioprostheses for Transcatheter Aortic Valve Replacement in Patients With Symptomatic Severe Aortic Stenosis: SCOPE 2 Randomized Clinical Trial.
    Tamburino C; Bleiziffer S; Thiele H; Scholtz S; Hildick-Smith D; Cunnington M; Wolf A; Barbanti M; Tchetchè D; Garot P; Pagnotta P; Gilard M; Bedogni F; Van Belle E; Vasa-Nicotera M; Chieffo A; Deutsch O; Kempfert J; Søndergaard L; Butter C; Trillo-Nouche R; Lotfi S; Möllmann H; Joner M; Abdel-Wahab M; Bogaerts K; Hengstenberg C; Capodanno D
    Circulation; 2020 Dec; 142(25):2431-2442. PubMed ID: 33054367
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The ACURATE neo Transcatheter Heart Valve: A Comprehensive Analysis of Predictors of Procedural Outcome.
    Kim WK; Möllmann H; Liebetrau C; Renker M; Rolf A; Simon P; Van Linden A; Arsalan M; Doss M; Hamm CW; Walther T
    JACC Cardiovasc Interv; 2018 Sep; 11(17):1721-1729. PubMed ID: 29803694
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Native aortic leaflets and permanent pacemaker implantation risk following balloon-expandable transcatheter aortic valve implantation.
    Chandrasekar B; AlMerri K; AlEnezi A; AlRashdan I; AlKhdair D; AlKandari F
    Indian Heart J; 2023; 75(4):268-273. PubMed ID: 37406856
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incidence, Predictors, and Prognostic Impact of New Permanent Pacemaker Implantation After TAVR With Self-Expanding Valves.
    Pagnesi M; Kim WK; Baggio S; Scotti A; Barbanti M; De Marco F; Adamo M; Eitan A; Estévez-Loureiro R; Conradi L; Toggweiler S; Mylotte D; Veulemans V; Søndergaard L; Wolf A; Giannini F; Maffeo D; Pilgrim T; Montorfano M; Zweiker D; Ferlini M; Kornowski R; Hildick-Smith D; Taramasso M; Abizaid A; Schofer J; Sinning JM; Van Mieghem NM; Wöhrle J; Khogali S; Van der Heyden JAS; Wood DA; Ielasi A; MacCarthy P; Brugaletta S; Hamm CW; Costa G; Testa L; Massussi M; Alarcón R; Schäfer U; Brunner S; Reimers B; Lunardi M; Zeus T; Vanhaverbeke M; Naber CK; Di Ienno L; Buono A; Windecker S; Schmidt A; Lanzillo G; Vaknin-Assa H; Arunothayaraj S; Saccocci M; Siqueira D; Brinkmann C; Sedaghat A; Ziviello F; Seeger J; Rottbauer W; Brouwer J; Buysschaert I; Jelisejevas J; Bharucha A; Regueiro A; Metra M; Colombo A; Latib A; Mangieri A
    JACC Cardiovasc Interv; 2023 Aug; 16(16):2004-2017. PubMed ID: 37480891
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation.
    van der Boon RM; Houthuizen P; Urena M; Poels TT; van Mieghem NM; Brueren GR; Altintas S; Nuis RJ; Serruys PW; van Garsse LA; van Domburg RT; Cabau JR; de Jaegere PP; Prinzen FW
    Catheter Cardiovasc Interv; 2015 Apr; 85(5):E144-52. PubMed ID: 25504891
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Incidence of new-onset left bundle branch block and predictors of new permanent pacemaker following transcatheter aortic valve replacement with the Portico™ valve.
    Walther T; Manoharan G; Linke A; Möllmann H; Holzhey D; Worthley SG; Kim WK; Schäfer U
    Eur J Cardiothorac Surg; 2018 Sep; 54(3):467-474. PubMed ID: 29534170
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes of three different new generation transcatheter aortic valve prostheses.
    Costa G; Buccheri S; Barbanti M; Picci A; Todaro D; Di Simone E; La Spina K; D'Arrigo P; Criscione E; Nastasi M; Sgroi C; Tamburino C
    Catheter Cardiovasc Interv; 2020 Feb; 95(3):398-407. PubMed ID: 31609073
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First North American experience with the transfemoral ACURATE-neo
    Bagur R; Teefy PJ; Kiaii B; Diamantouros P; Chu MWA
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):130-138. PubMed ID: 27677241
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.