These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
195 related articles for article (PubMed ID: 3337360)
1. Treatment of air embolism with a special pulmonary artery catheter introducer sheath in sitting dogs. Bowdle TA; Artru AA Anesthesiology; 1988 Jan; 68(1):107-10. PubMed ID: 3337360 [TBL] [Abstract][Full Text] [Related]
2. Bunegin-Albin catheter improves air retrieval and resuscitation from lethal venous air embolism in upright dogs. Colley PS; Artru AA Anesth Analg; 1989 Mar; 68(3):298-301. PubMed ID: 2919770 [TBL] [Abstract][Full Text] [Related]
3. Bunegin-Albin catheter improves air retrieval and resuscitation from lethal venous air embolism in dogs. Colley PS; Artru AA Anesth Analg; 1987 Oct; 66(10):991-4. PubMed ID: 3631598 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a double-lumen multiorifice catheter for resuscitation of swine from lethal venous air embolism. Mongan PD; Hinman JA Anesthesiology; 1995 Nov; 83(5):1104-11. PubMed ID: 7486162 [TBL] [Abstract][Full Text] [Related]
5. A pulmonary artery catheter does not affect the intravascular electrocardiogram from the air aspiration introducer sheath. Artru AA; Bowdle A J Neurosurg Anesthesiol; 1991 Mar; 3(1):61-3. PubMed ID: 10147759 [TBL] [Abstract][Full Text] [Related]
6. Positioning the air aspiration pulmonary artery catheter introducer sheath by intravascular electrocardiography. Bowdle TA; Artru AA Anesthesiology; 1988 Aug; 69(2):276-9. PubMed ID: 3407978 [No Abstract] [Full Text] [Related]
7. In vitro comparison of central venous catheters for aspiration of venous air embolism: effect of catheter type, catheter tip position, and cardiac inclination. Hanna PG; Gravenstein N; Pashayan AG J Clin Anesth; 1991; 3(4):290-4. PubMed ID: 1910796 [TBL] [Abstract][Full Text] [Related]
8. Venous air embolism in prone dogs positioned with the abdomen hanging freely: percentage of gas retrieved and success rate of resuscitation. Artru AA Anesth Analg; 1992 Nov; 75(5):715-9. PubMed ID: 1416123 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of catheter placement in the treatment of venous air embolism. Sink JD; Comer PB; James PM; Loveland SR Ann Surg; 1976 Jan; 183(1):58-61. PubMed ID: 1247302 [TBL] [Abstract][Full Text] [Related]
10. A large catheter sheath introducer with an increased side-port functional gauge. Benumof JL; Wyte SR; Rogers SN Crit Care Med; 1983 Aug; 11(8):660-2. PubMed ID: 6872555 [TBL] [Abstract][Full Text] [Related]
11. Pressure monitoring can accurately position catheters for air embolism aspiration. Mongan P; Peterson RE; Culling RD J Clin Monit; 1992 Apr; 8(2):121-5. PubMed ID: 1583547 [TBL] [Abstract][Full Text] [Related]
12. Placement of a multiorificed catheter in the inferior portion of the right atrium; percentage of gas retrieved and success rate of resuscitation after venous air embolism in prone dogs positioned with the abdomen hanging freely. Artru AA Anesth Analg; 1994 Oct; 79(4):740-4. PubMed ID: 7943785 [TBL] [Abstract][Full Text] [Related]
13. Air embolism during insertion of central venous catheters. Vesely TM J Vasc Interv Radiol; 2001 Nov; 12(11):1291-5. PubMed ID: 11698628 [TBL] [Abstract][Full Text] [Related]
14. Bench-top evaluation of air flow through a valved peelable introducer sheath. Vesely TM; Ness PJ; Hart JE J Vasc Interv Radiol; 2005 Nov; 16(11):1517-22. PubMed ID: 16319160 [TBL] [Abstract][Full Text] [Related]
16. Intracardiac transvenous echocardiography is superior to both precordial Doppler and transesophageal echocardiography techniques for detecting venous air embolism and catheter-guided air aspiration. Schäfer ST; Lindemann J; Brendt P; Kaiser G; Peters J Anesth Analg; 2008 Jan; 106(1):45-54, table of contents. PubMed ID: 18165549 [TBL] [Abstract][Full Text] [Related]
17. Thermodilution cardiac output values obtained by using a centrally placed introducer sheath and right atrial port of a pulmonary artery catheter. Hunn D; Gobel FL; Pedersen W; Madison C; Roeller S; Bullemer F; Goldenberg IF Crit Care Med; 1990 Apr; 18(4):438-9. PubMed ID: 2318054 [TBL] [Abstract][Full Text] [Related]
18. Effects of insertion depth and use of the sidearm of the introducer sheath of pulmonary artery catheters in cardiac output measurement. Boyd O; Mackay CJ; Newman P; Bennett ED; Grounds RM Crit Care Med; 1994 Jul; 22(7):1132-5. PubMed ID: 8026202 [TBL] [Abstract][Full Text] [Related]
19. Modification of a new catheter for air retrieval and resuscitation from lethal venous air embolism: effect of nitrous oxide on air retrieval. Artru AA Anesth Analg; 1992 Aug; 75(2):226-31. PubMed ID: 1632537 [TBL] [Abstract][Full Text] [Related]
20. The site of origin of the intravascular electrocardiogram recorded from multiorificed intravascular catheters. Artru AA; Colley PS Anesthesiology; 1988 Jul; 69(1):44-8. PubMed ID: 3389565 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]