These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 33377496)

  • 21. Influence of perfusate on liver viability during hypothermic machine perfusion.
    Jia JJ; Zhang J; Li JH; Chen XD; Jiang L; Zhou YF; He N; Xie HY; Zhou L; Zheng SS
    World J Gastroenterol; 2015 Aug; 21(29):8848-57. PubMed ID: 26269674
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Prolongation of the Time Window From Traumatic Limb Amputation to Replantation From 6 to 33 Hours Using Ex Vivo Limb Perfusion.
    Zhang L; Ipaktchi R; Ben Brahim B; Arenas Hoyos I; Jenni H; Dietrich L; Despont A; Shaw-Boden J; Büttiker S; Siegrist D; Gultom M; Parodi C; Garcia Casalta L; Petrucci M; Petruccione I; Mirra A; Nettelbeck K; Wang J; de Brot S; Voegelin E; Casoni D; Rieben R
    Mil Med; 2024 Aug; 189(Supplement_3):83-92. PubMed ID: 39160844
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of fluorocarbon perfusion upon the preservation of amputated limbs. An experimental study.
    Usui M; Sakata H; Ishii S
    J Bone Joint Surg Br; 1985 May; 67(3):473-7. PubMed ID: 3997959
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ex-vivo perfusion as a successful strategy for reduction of ischemia-reperfusion injury in prolonged muscle flap preservation - A gene expression study.
    Kruit AS; Smits L; Pouwels A; Schreinemachers MJM; Hummelink SLM; Ulrich DJO
    Gene; 2019 Jun; 701():89-97. PubMed ID: 30902788
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The effects of perfusion on an amputated extremity.
    Hicks TE; Boswick JA; Solomons CC
    J Trauma; 1980 Aug; 20(8):632-48. PubMed ID: 6157031
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A new liver autotransplantation technique using subnormothermic machine perfusion for organ preservation in a porcine model.
    Gringeri E; Polacco M; D'Amico FE; Scopelliti M; Bassi D; Bonsignore P; Luisetto R; Lodo E; Carraro A; Zanus G; Cillo U
    Transplant Proc; 2011 May; 43(4):997-1000. PubMed ID: 21620035
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The Effect of Ex Situ Perfusion in a Swine Limb Vascularized Composite Tissue Allograft on Survival up to 24 Hours.
    Ozer K; Rojas-Pena A; Mendias CL; Bryner BS; Toomasian C; Bartlett RH
    J Hand Surg Am; 2016 Jan; 41(1):3-12. PubMed ID: 26710728
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Normothermic ex vivo liver perfusion using steen solution as perfusate for human liver transplantation: First North American results.
    Selzner M; Goldaracena N; Echeverri J; Kaths JM; Linares I; Selzner N; Serrick C; Marquez M; Sapisochin G; Renner EL; Bhat M; McGilvray ID; Lilly L; Greig PD; Tsien C; Cattral MS; Ghanekar A; Grant DR
    Liver Transpl; 2016 Nov; 22(11):1501-1508. PubMed ID: 27339754
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Use of modified Custodiol-N as perfusion solution in ex vivo lung perfusion.
    Olbertz C; Pizanis N; Bäumker H; Kalka K; Aigner C; Rauen U; Nolte I; Kamler M; Koch A
    Am J Transl Res; 2020; 12(1):153-161. PubMed ID: 32051744
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Oxygenated machine perfusion at room temperature as an alternative for static cold storage in porcine donor hearts.
    van Suylen V; Vandendriessche K; Neyrinck A; Nijhuis F; van der Plaats A; Verbeken EK; Vermeersch P; Meyns B; Mariani MA; Rega F; Erasmus ME
    Artif Organs; 2022 Feb; 46(2):246-258. PubMed ID: 34633676
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effects of immediate versus delayed ex-vivo lung perfusion in a porcine cardiac arrest donation model.
    Olbertz C; Pizanis N; Bäumker H; Becker S; Aigner C; Rauen U; Nolte I; Kamler M; Koch A
    Int J Artif Organs; 2019 Jul; 42(7):362-369. PubMed ID: 31238824
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Continuous Normothermic Ex Vivo Kidney Perfusion Improves Graft Function in Donation After Circulatory Death Pig Kidney Transplantation.
    Kaths JM; Echeverri J; Chun YM; Cen JY; Goldaracena N; Linares I; Dingwell LS; Yip PM; John R; Bagli D; Mucsi I; Ghanekar A; Grant DR; Robinson LA; Selzner M
    Transplantation; 2017 Apr; 101(4):754-763. PubMed ID: 27467537
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Rewarming preservation by organ perfusion system for donation after cardiac death liver grafts in pigs.
    Matsuno N; Obara H; Watanabe R; Iwata S; Kono S; Fujiyama M; Hirano T; Kanazawa H; Enosawa S
    Transplant Proc; 2014 May; 46(4):1095-8. PubMed ID: 24815137
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Developing a protocol for normothermic ex-situ limb perfusion.
    Duraes EFR; Madajka M; Frautschi R; Soliman B; Cakmakoglu C; Barnett A; Tadisina K; Liu Q; Grady P; Quintini C; Okamoto T; Papay F; Rampazzo A; Bassiri Gharb B
    Microsurgery; 2018 Feb; 38(2):185-194. PubMed ID: 28990205
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Continuous versus Pulsatile Flow in 24-Hour Vascularized Composite Allograft Machine Perfusion in Swine: A Pilot Study.
    Tawa P; Goutard M; Andrews AR; de Vries RJ; Rosales IA; Yeh H; Uygun B; Randolph MA; Lellouch AG; Uygun K; Cetrulo CL
    J Surg Res; 2023 Mar; 283():1145-1153. PubMed ID: 36915006
    [TBL] [Abstract][Full Text] [Related]  

  • 36. L-alanyl-L-glutamine modified perfusate improves human lung cell functions and extend porcine ex vivo lung perfusion.
    Huang L; Hough O; Vellanki RN; Takahashi M; Zhu Z; Xiang YY; Chen M; Gokhale H; Shan H; Soltanieh S; Jing L; Gao X; Wouters BG; Cypel M; Keshavjee S; Liu M
    J Heart Lung Transplant; 2023 Feb; 42(2):183-195. PubMed ID: 36411189
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improved preservation of skeletal muscle in amputated limbs using pulsatile hypothermic perfusion with University of Wisconsin solution. A preliminary study.
    Gordon L; Levinsohn DG; Borowsky CD; Manojlovic RD; Sessler DI; Weiner MW; Baker AJ
    J Bone Joint Surg Am; 1992 Oct; 74(9):1358-66. PubMed ID: 1429791
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A novel oxygenated machine perfusion system for preservation of the liver.
    Dirkes MC; Post IC; Heger M; van Gulik TM
    Artif Organs; 2013 Aug; 37(8):719-24. PubMed ID: 23614839
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Extended hypothermic oxygenated machine perfusion enables
    Brüggenwirth IMA; van Leeuwen OB; de Vries Y; Bodewes SB; Adelmeijer J; Wiersema-Buist J; Lisman T; Martins PN; de Meijer VE; Porte RJ
    JHEP Rep; 2020 Apr; 2(2):100092. PubMed ID: 32195456
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Experimental study on effect of power-assisted intravascular shunt in replantation of amputated limbs in rabbits].
    Li H; Zheng C; He H; Bai Z; Zhu Q; Hu X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Dec; 28(12):1519-24. PubMed ID: 25826899
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.