496 related articles for article (PubMed ID: 33378092)
1. Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small-field animal irradiation studies.
Ba Sunbul N; Oraiqat I; Rosen B; Miller C; Meert C; Matuszak MM; Clarke S; Pozzi S; Moran JM; El Naqa I
Med Phys; 2021 Mar; 48(3):1404-1416. PubMed ID: 33378092
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric and geometric characteristics of a small animal image-guided irradiator using 3D dosimetry/optical CT scanner.
Na YH; Wang YF; Black PJ; Velten C; Qian X; Lin SC; Adamovics J; Wuu CS
Med Phys; 2018 Jul; 45(7):3330-3339. PubMed ID: 29746014
[TBL] [Abstract][Full Text] [Related]
3. Integrating X-ray kV millimetric field dosimetry with a synthetic diamond detector into the treatment planning system commissioning of a preclinical irradiator.
Muñoz Arango E; Beltrán Gómez C; Alaminos-Bouza A; de Almeida CE
Med Phys; 2021 Jul; 48(7):4038-4052. PubMed ID: 33797098
[TBL] [Abstract][Full Text] [Related]
4. Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.
Newton J; Oldham M; Thomas A; Li Y; Adamovics J; Kirsch DG; Das S
Med Phys; 2011 Dec; 38(12):6754-62. PubMed ID: 22149857
[TBL] [Abstract][Full Text] [Related]
5. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.
McCaw TJ; Micka JA; DeWerd LA
Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393
[TBL] [Abstract][Full Text] [Related]
6. Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning.
Babic S; McNiven A; Battista J; Jordan K
Phys Med Biol; 2009 Apr; 54(8):2463-81. PubMed ID: 19336848
[TBL] [Abstract][Full Text] [Related]
7. Small-field measurement and Monte Carlo model validation of a novel image-guided radiotherapy system.
Shi M; Chuang CF; Kovalchuk N; Bush K; Zaks D; Xing L; Surucu M; Han B
Med Phys; 2021 Nov; 48(11):7450-7460. PubMed ID: 34628666
[TBL] [Abstract][Full Text] [Related]
8. Application of high field magnetic resonance microimaging in polymer gel dosimetry.
Skorupa A; Woźnica A; Ciszek M; Staniszewski M; Kijonka M; Kozicki M; Woźniak B; Orlef A; Polański A; Boguszewicz Ł; Sokół M
Med Phys; 2020 Aug; 47(8):3600-3613. PubMed ID: 32301510
[TBL] [Abstract][Full Text] [Related]
9. An Experimental Slope Method for a More Accurate Measurement of Relative Radiation Doses using Radiographic and Radiochromic Films and Its Application to Megavoltage Small-Field Dosimetry.
Holla R; Khanna D; Pillai BK; Jafar Ali KV; Renil Mon PS; Clinto CO; Ganesh T
J Med Phys; 2019; 44(3):145-155. PubMed ID: 31576063
[TBL] [Abstract][Full Text] [Related]
10. Dosimetric verification and commissioning for a small animal image-guided irradiator.
Wang YF; Lin SC; Na YH; Black PJ; Wuu CS
Phys Med Biol; 2018 Jul; 63(14):145001. PubMed ID: 29923495
[TBL] [Abstract][Full Text] [Related]
11. Small-field beam data acquisition, detector dependency, and film-based validation for a novel self-shielded stereotactic radiosurgery system.
Pinnaduwage DS; Srivastava SP; Yan X; Jani SS; Jenkins C; Barani IJ; Sorensen S
Med Phys; 2021 Oct; 48(10):6121-6136. PubMed ID: 34260069
[TBL] [Abstract][Full Text] [Related]
12. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.
Casar B; Gershkevitsh E; Mendez I; Jurković S; Huq MS
Med Phys; 2019 Feb; 46(2):944-963. PubMed ID: 30521073
[TBL] [Abstract][Full Text] [Related]
13. N-isopropylacrylamide gel dosimeter to evaluate clinical photon beam characteristics.
Chiu CY; Tsang YW; Hsieh BT
Appl Radiat Isot; 2014 Aug; 90():245-50. PubMed ID: 24836904
[TBL] [Abstract][Full Text] [Related]
14. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
[TBL] [Abstract][Full Text] [Related]
15. Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
Massillon-J L G; Cueva-Prócel D; Díaz-Aguirre P; Rodríguez-Ponce M; Herrera-Martínez F
PLoS One; 2013; 8(5):e63418. PubMed ID: 23671677
[TBL] [Abstract][Full Text] [Related]
16. Analysis of various beamlet sizes for IMRT with 6 MV photons.
Sohn JW; Dempsey JF; Suh TS; Low DA
Med Phys; 2003 Sep; 30(9):2432-9. PubMed ID: 14528965
[TBL] [Abstract][Full Text] [Related]
17. A simulation study of ionizing radiation acoustic imaging (iRAI) as a real-time dosimetric technique for ultra-high dose rate radiotherapy (UHDR-RT).
Ba Sunbul NH; Zhang W; Oraiqat I; Litzenberg DW; Lam KL; Cuneo K; Moran JM; Carson PL; Wang X; Clarke SD; Matuszak MM; Pozzi SA; El Naqa I
Med Phys; 2021 Oct; 48(10):6137-6151. PubMed ID: 34431520
[TBL] [Abstract][Full Text] [Related]
18. Real-time in vivo dosimetry system based on an optical fiber-coupled microsized photostimulable phosphor for stereotactic body radiation therapy.
Yada R; Maenaka K; Miyamoto S; Okada G; Sasakura A; Ashida M; Adachi M; Sato T; Wang T; Akasaka H; Mukumoto N; Shimizu Y; Sasaki R
Med Phys; 2020 Oct; 47(10):5235-5249. PubMed ID: 32654194
[TBL] [Abstract][Full Text] [Related]
19. The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy.
Arnfield MR; Otto K; Aroumougame VR; Alkins RD
Med Phys; 2005 Jan; 32(1):12-8. PubMed ID: 15719949
[TBL] [Abstract][Full Text] [Related]
20. Investigation of a 3D dosimetry system utilizing radio-chromic gel and telecentric optical-CT readout.
Hoopingarner S; Oldham M; Adamson J; Lakrad K
Med Phys; 2023 Sep; 50(9):5734-5744. PubMed ID: 37485846
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]