BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 3338181)

  • 1. Heterophilic antibodies: a problem for all immunoassays.
    Boscato LM; Stuart MC
    Clin Chem; 1988 Jan; 34(1):27-33. PubMed ID: 3338181
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test.
    Vladutiu AO; Sulewski JM; Pudlak KA; Stull CG
    JAMA; 1982 Nov; 248(19):2489-90. PubMed ID: 6897083
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Heterophilic antibodies against rabbit serum causing falsely elevated gonadotropin levels.
    Berglund L; Holmberg NG
    Acta Obstet Gynecol Scand; 1989; 68(4):377-8. PubMed ID: 2515728
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.
    Patel KK; Gronowski AM
    Clin Biochem; 2016 Jun; 49(9):729-731. PubMed ID: 26968106
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Eliminating interference from heterophilic antibodies in a two-site immunoassay for creatine kinase MB by using F(ab')2 conjugate and polyclonal mouse IgG.
    Vaidya HC; Beatty BG
    Clin Chem; 1992 Sep; 38(9):1737-42. PubMed ID: 1526006
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Heterophile antibody blocking agent to confirm false positive serum human chorionic gonadotropin assay.
    Esfandiari N; Goldberg JM
    Obstet Gynecol; 2003 May; 101(5 Pt 2):1144-6. PubMed ID: 12738132
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Heterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera.
    Bolstad N; Warren DJ; Bjerner J; Kravdal G; Schwettmann L; Olsen KH; Rustad P; Nustad K
    Clin Chem Lab Med; 2011 Sep; 49(12):2001-6. PubMed ID: 21899496
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Human heterophilic antibodies display specificity for murine IgG subclasses.
    Bjerner J; Olsen KH; Børmer OP; Nustad K
    Clin Biochem; 2005 May; 38(5):465-72. PubMed ID: 15820778
    [TBL] [Abstract][Full Text] [Related]  

  • 9. False-positive human chorionic gonadotropin levels caused by a heterophile antibody with the immunoradiometric assay.
    Check JH; Nowroozi K; Chase JS; Lauer C; Elkins B; Wu CH
    Am J Obstet Gynecol; 1988 Jan; 158(1):99-100. PubMed ID: 2447778
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pseudohypergonadotropinemia and pseudohyperprolactinemia induced by heterophilic antibodies?
    Dericks-Tan JS; Jost A; Schwedes U; Taubert HD
    Klin Wochenschr; 1984 Mar; 62(6):265-73. PubMed ID: 6425554
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of heterophilic antibody blocking agent (HBT) in reducing false-positive hCG results.
    Butler SA; Cole LA
    Clin Chem; 2001; 47(7):1332-3. PubMed ID: 11427478
    [No Abstract]   [Full Text] [Related]  

  • 12. Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using a human/mouse chimeric antibody to CEA as the tracer.
    Kuroki M; Matsumoto Y; Arakawa F; Haruno M; Murakami M; Kuwahara M; Ozaki H; Senba T; Matsuoka Y
    J Immunol Methods; 1995 Mar; 180(1):81-91. PubMed ID: 7897248
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Artefactual increase in serum thyrotropin concentration caused by heterophilic antibodies with specificity for IgG of the family Bovidea.
    Bartlett WA; Browning MC; Jung RT
    Clin Chem; 1986 Dec; 32(12):2214-9. PubMed ID: 3779994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Human chorionic gonadotropin suspected heterophile interference investigations in immunoassays: a recommended approach.
    Jara-Aguirre JC; Baumann NA; Block DR; Algeciras-Schimnich A
    Clin Chem Lab Med; 2019 Jul; 57(8):1192-1196. PubMed ID: 30753153
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prevalence of heterophilic antibody interference in eight automated tumor marker immunoassays.
    Preissner CM; Dodge LA; O'Kane DJ; Singh RJ; Grebe SK
    Clin Chem; 2005 Jan; 51(1):208-10. PubMed ID: 15613712
    [No Abstract]   [Full Text] [Related]  

  • 16. Interference by heterophilic antibodies in immunoassays: wrong increase of myoglobin values.
    Bonetti A; Monica C; Bonaguri C; Gnocchi C; Russo A; Battistelli L; Musiari L; Pastori P; Novarini A
    Acta Biomed; 2008 Aug; 79(2):140-3. PubMed ID: 18788511
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Studies of monoclonal antibodies against human chorionic gonadotropin. II. Applications of human chorionic gonadotropin monoclonal antibodies on immunoassays.
    Chow SN; Hsieh CY; Ouyang PC; Leung WY; Ho-Yuen B; Lee CY
    Diagn Immunol; 1986; 4(4):194-200. PubMed ID: 3530599
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Heterophilic serum antibodies: a cause for falsely elevated serum thyrotropin levels.
    Brennan MD; Klee GG; Preissner CM; Hay ID
    Mayo Clin Proc; 1987 Oct; 62(10):894-8. PubMed ID: 3657306
    [TBL] [Abstract][Full Text] [Related]  

  • 19. False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations.
    Rotmensch S; Cole LA
    Lancet; 2000 Feb; 355(9205):712-5. PubMed ID: 10703803
    [TBL] [Abstract][Full Text] [Related]  

  • 20. False hyperthyrotropinemia induced by heterophilic antibodies against rabbit serum.
    Schaison G; Thomopoulos P; Moulias R; Feinstein MC
    J Clin Endocrinol Metab; 1981 Jul; 53(1):200-2. PubMed ID: 6894601
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.