These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 3338181)

  • 21. Eliminating heterophilic antibody interference for ferritin detection using Olympus F(ab')2 based reagent.
    Grouzmann E; Dayer N; Bain C; Neville CM; McCusker MD; Wang RY
    Clin Lab; 2008; 54(9-10):355-7. PubMed ID: 19097493
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reducing heterophilic antibody interference in immunoassays using single-chain antibodies.
    Baird CL; Tan R; Fischer CJ; Victry KD; Zangar RC; Rodland KD
    Anal Biochem; 2011 Dec; 419(2):333-5. PubMed ID: 21933659
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Erroneous augmentation of multiplex assay measurements in patients with rheumatoid arthritis due to heterophilic binding by serum rheumatoid factor.
    Todd DJ; Knowlton N; Amato M; Frank MB; Schur PH; Izmailova ES; Roubenoff R; Shadick NA; Weinblatt ME; Centola M; Lee DM
    Arthritis Rheum; 2011 Apr; 63(4):894-903. PubMed ID: 21305505
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Avoiding inappropriate clinical decisions based on false-positive human chorionic gonadotropin test results.
    ACOG Committee on Gynecologic Practice
    Int J Gynaecol Obstet; 2003 Feb; 80(2):231-3. PubMed ID: 12627604
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Canine heterophilic antibodies as a source of false-positive B-type natriuretic peptide sandwich ELISA results.
    Solter PF; Oyama MA; Sisson DD
    Vet Clin Pathol; 2008 Mar; 37(1):86-95. PubMed ID: 18366550
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Heterophilic antibody interference in immunometric assays.
    Bolstad N; Warren DJ; Nustad K
    Best Pract Res Clin Endocrinol Metab; 2013 Oct; 27(5):647-61. PubMed ID: 24094636
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs.
    Hennig C; Rink L; Fagin U; Jabs WJ; Kirchner H
    J Immunol Methods; 2000 Feb; 235(1-2):71-80. PubMed ID: 10675759
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Heterophilic antibodies in human sera causing falsely increased results in the CA 125 immunofluorometric assay.
    Boerman OC; Segers MF; Poels LG; Kenemans P; Thomas CM
    Clin Chem; 1990 Jun; 36(6):888-91. PubMed ID: 2357827
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Persistent low levels of serum hCG due to heterophilic mouse antibodies: an unrecognized pitfall in the diagnosis of trophoblastic disease.
    González Aguilera B; Syrios P; Gadisseur R; Luyckx F; Cavalier E; Beckers A; Valdes-Socin H
    Gynecol Endocrinol; 2016 Jun; 32(6):439-41. PubMed ID: 26792068
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Heterophilic antibody interference in a non-endogenous molecule assay: an apparent elevation in the tacrolimus concentration.
    Altinier S; Varagnolo M; Zaninotto M; Boccagni P; Plebani M
    Clin Chim Acta; 2009 Apr; 402(1-2):193-5. PubMed ID: 19150346
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Prevalence of heterophilic antibodies in serum samples from horses in an equine hospital, and elimination of interference using chicken IgY.
    Dong B; Bergman D; Holst BS
    Acta Vet Scand; 2021 Mar; 63(1):10. PubMed ID: 33712042
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Specificity of two-site immunoassays.
    Boscato LM; Egan GM; Stuart MC
    J Immunol Methods; 1989 Feb; 117(2):221-9. PubMed ID: 2466086
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Heterophilic antibody as a source of error in immunoassay.
    Witherspoon LR; Witkin M; Shuler SE; Neely H; Gilbert S
    South Med J; 1986 Jul; 79(7):836-9. PubMed ID: 3088731
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Rapid and simple immunoassays for measurement of human chorionic gonadotropin using monoclonal antibodies.
    Chow SN; Ouyang PC; Chu CT; Lee CY
    J Formos Med Assoc; 1990 Sep; 89(9):792-8. PubMed ID: 1982540
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Heterophilic antibodies remain a problem for the immunoassay laboratory.
    Ward G; McKinnon L; Badrick T; Hickman PE
    Am J Clin Pathol; 1997 Oct; 108(4):417-21. PubMed ID: 9322595
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A method for routine detection of heterophile antibody interference in the Abbott AxSYM hCG assay.
    Jones GR; Giannopoulos P
    Pathology; 2004 Aug; 36(4):364-6. PubMed ID: 15370140
    [No Abstract]   [Full Text] [Related]  

  • 37. Interference from heterophilic antibodies in the Olympus ferritin method.
    Blanco M; Varela C
    Clin Chem; 2006 Aug; 52(8):1623-4. PubMed ID: 16873313
    [No Abstract]   [Full Text] [Related]  

  • 38. Identification of epitopes associated with hCG and the beta hCG carboxyl terminus by monoclonal antibodies produced against a synthetic peptide.
    Bidart JM; Ozturk M; Bellet DH; Jolivet M; Gras-Masse H; Troalen F; Bohuon CJ; Wands JR
    J Immunol; 1985 Jan; 134(1):457-64. PubMed ID: 2578049
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monoclonal antibodies to human chorionic gonadotropin: implications for antigenic mapping, immunoradiometric assays, and clinical applications.
    Norman RJ; Poulton T; Gard T; Chard T
    J Clin Endocrinol Metab; 1985 Dec; 61(6):1031-8. PubMed ID: 2414309
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A circular antibody-antigen complex is responsible for increased affinity shown by mixtures of monoclonal antibodies to human chorionic gonadotropin.
    Moyle WR; Anderson DM; Ehrlich PH
    J Immunol; 1983 Oct; 131(4):1900-5. PubMed ID: 6619544
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.