BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

309 related articles for article (PubMed ID: 33389052)

  • 1. New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate.
    Freitas A; Bontempo RL; Azevedo FAR; Battaglion LR; Giordano MN; Barin FR; Giordano V
    Eur J Orthop Surg Traumatol; 2021 Aug; 31(6):1069-1075. PubMed ID: 33389052
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical study on parallel cannulated compression screw combined with medial buttress plate fixation and F-type cannulated compression screw fixation in Pauwels III femoral neck fracture:A finite element analysis.
    Wang J; Gao Y; Song D; Ni J
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2022 Aug; 47(8):1143-1153. PubMed ID: 36097783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture.
    Tianye L; Peng Y; Jingli X; QiuShi W; GuangQuan Z; Wei H; Qingwen Z
    Biomed Pharmacother; 2019 Apr; 112():108658. PubMed ID: 30970508
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical study of different internal fixations in Pauwels type III femoral neck fracture - A finite elements analysis.
    Freitas A; Toledo Júnior JV; Ferreira Dos Santos A; Aquino RJ; Leão VN; Péricles de Alcântara W
    J Clin Orthop Trauma; 2021 Mar; 14():145-150. PubMed ID: 33717906
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture.
    Teng Y; Zhang Y; Guo C
    Medicine (Baltimore); 2022 Jul; 101(28):e29450. PubMed ID: 35839002
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical evaluation of different internal fixation methods based on finite element analysis for Pauwels type III femoral neck fracture.
    Jiang X; Liang K; Du G; Chen Y; Tang Y; Geng K
    Injury; 2022 Oct; 53(10):3115-3123. PubMed ID: 35999063
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Biomechanical analysis of four internal fixations for Pauwels Ⅲ femoral neck fractures with defects].
    Su ZH; Tan HL; Xu ZH; Li PF; Wang YQ; Li S; Ni M
    Zhongguo Gu Shang; 2023 Mar; 36(3):255-61. PubMed ID: 36946019
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pre-sliding of femoral neck system improves fixation stability in pauwels type III femoral neck fracture: a finite element analysis.
    Cha Y; Chung JY; Jung CH; Kim JW; Lee J; Yoo JI; Kim JT; Jeon Y
    BMC Musculoskelet Disord; 2023 Jun; 24(1):506. PubMed ID: 37344858
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro biomechanical analysis of a locking self-compression screw model applied to Pauwels III and comminuted femoral neck fractures.
    de Oliveira MM; Freitas A; Giordano V; Moura CMDC; Ferreira BL; Lucas LG; Pires RE; Belangero WD
    Injury; 2023 Nov; 54 Suppl 6():110810. PubMed ID: 38143133
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw.
    Huang H; Feng Z; Wang W; Yang C; Liao J; Ouyang J
    Med Sci Monit; 2021 Mar; 27():e929163. PubMed ID: 33782376
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Finite element analysis of optimal selection of cannulated threaded screw for the prevention of femoral neck shortening after internal fixation for femoral neck fracture].
    Chen ZM; Yang F; Yu S; Shi ZW; Yu X; Chen XJ; Shi L; Wang CH; Pang QJ
    Zhongguo Gu Shang; 2022 Nov; 35(11):1042-8. PubMed ID: 36415189
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical Study Using the Finite Element Method of Internal Fixation in Pauwels Type III Vertical Femoral Neck Fractures.
    Noda M; Saegusa Y; Takahashi M; Tezuka D; Adachi K; Naoi K
    Arch Trauma Res; 2015 Sep; 4(3):e23167. PubMed ID: 26566507
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis.
    Freitas A; Barin FR; Battaglion LR; da Costa HI; Santos ED; Rosado HA; Giordano M; Giordano V; Shimano AC
    Indian J Orthop; 2021 Jul; 55(Suppl 2):378-384. PubMed ID: 34306551
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures.
    Nan C; Li Y; Liu Y; Ma L; Ma Z
    Technol Health Care; 2023; 31(4):1161-1170. PubMed ID: 36872803
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis.
    Lin S; Shang J; Xing B; Wu B; Peng R; Wang G; Lu HD
    BMC Musculoskelet Disord; 2021 Sep; 22(1):758. PubMed ID: 34488708
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis.
    Huang BX; Zhan SZ; Yang M; Zhang DY
    BMC Musculoskelet Disord; 2023 Apr; 24(1):292. PubMed ID: 37059976
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element analysis of necessity of reduction and selection of internal fixation for valgus-impacted femoral neck fracture.
    Dai Y; Ni M; Dou B; Wang Z; Zhang Y; Cui X; Ma W; Qin T; Xu X; Mei J
    Comput Methods Biomech Biomed Engin; 2023 May; 26(7):846-853. PubMed ID: 35754380
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis.
    Fan X; Zhou Y; Dai S; Lao K; Zhang Q; Yu T
    BMC Musculoskelet Disord; 2024 Jan; 25(1):83. PubMed ID: 38245678
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis.
    Zhan S; Jiang D; Xu J; Ling M; Yang K; Li Y; Jia W; Hu H; Zhang C
    BMC Musculoskelet Disord; 2020 Dec; 21(1):842. PubMed ID: 33308185
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A quantitative biomechanical study of positive buttress techniques for femoral neck fractures: a finite element analysis.
    Wang G; Wang B; Tang Y; Yang HL
    Chin Med J (Engl); 2019 Nov; 132(21):2588-2593. PubMed ID: 31658158
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.