These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

55 related articles for article (PubMed ID: 3339083)

  • 1. Central venous blood temperature for rate control of physiological pacemakers.
    Alt E; Hirgstetter C; Heinz M; Theres H; Blömer H
    J Cardiovasc Surg (Torino); 1988; 29(1):80-8. PubMed ID: 3339083
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rate control of physiologic pacemakers by central venous blood temperature.
    Alt E; Hirgstetter C; Heinz M; Blömer H
    Circulation; 1986 Jun; 73(6):1206-12. PubMed ID: 3698253
    [TBL] [Abstract][Full Text] [Related]  

  • 3. First clinical results with a new temperature-controlled rate-responsive pacemaker. Comparison of Activitrax and Nova MR pacemakers with VVI/AAI pacing.
    Alt E; Völker R; Högl B; MacCarter D
    Circulation; 1988 Nov; 78(5 Pt 2):III116-24. PubMed ID: 3180390
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of right ventricular blood temperature during exercise as a means of rate control in physiological pacemakers.
    Alt E; Hirgstetter C; Heinz M; Theres H
    Pacing Clin Electrophysiol; 1986 Nov; 9(6):970-7. PubMed ID: 2432577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Effect of respiration on variations of central venous blood temperature].
    Alt E; Heinz M; Hirgstetter C; Theres H; Theiss W
    Z Kardiol; 1987 Oct; 76(10):643-7. PubMed ID: 3687167
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Behavior of central venous blood temperature in short duration and repeated stress--possibilities for temperature controlled frequency-adapted pacemaker stimulation].
    Alt E; Hirgstetter C; Theres H; Heinz M
    Z Kardiol; 1988 Apr; 77(4):214-21. PubMed ID: 3388937
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of different body-exercise modes on the rate response of the temperature-controlled pacemaker Nova MR.
    Zegelman M; Winter UJ; Alt E; Treese N; Kreuzer J; Henry L; Mugica J; Schroeder E; Klein H; Völker R
    Thorac Cardiovasc Surg; 1990 Jun; 38(3):181-5. PubMed ID: 2375035
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the pacing rate response to treadmill exercise using computer simulation of a temperature-based, rate-adaptive algorithm.
    Evans ML; Fearnot NE
    Med Instrum; 1988 Aug; 22(4):182-8. PubMed ID: 3173171
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Case studies on the effect of exercise and hot water submersion on intracardiac temperature and the performance of a pacemaker which varies pacing rate based on temperature.
    Fearnot NE; Kitoh O; Fujita T; Okamura H; Smith HJ; Calderini M
    Jpn Heart J; 1989 May; 30(3):353-63. PubMed ID: 2795873
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Is the response to cardiac pacing controlled by central venous temperature physiological?].
    Novák M; Smola M; Psenicka M; Stanĕk F
    Bratisl Lek Listy; 1997 Nov; 98(11):613-5. PubMed ID: 9525054
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Right ventricular blood temperature profiles for rate responsive pacing.
    Sellers TD; Fearnot NE; Smith HJ; Di Lorenzo DM; Knight JA; Schmaltz MJ
    Pacing Clin Electrophysiol; 1987 May; 10(3 Pt 1):467-79. PubMed ID: 2439994
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Cardiopulmonary stress test in variable frequency stimulation: a comparison of Activitrax and Nova-MR pacemakers in VVI/AAI stimulation].
    Alt E; Völker R; Högl B; MacCarter D
    Z Kardiol; 1988 Jul; 77(7):456-63. PubMed ID: 3062957
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Assessment of sensing parameters in the rate responsive cardiac pacemaker].
    Saito H; Toyoshima T; Tamura T; Su SC; Togawa T; Suma K
    Tokyo Ika Shika Daigaku Iyo Kizai Kenkyusho Hokoku; 1989; 23():97-103. PubMed ID: 2488971
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Central venous temperature sensing].
    Tanaka S; Ikeshita M; Asano T; Osaka S; Kutsukata N; Bessho R; Hosaka H; Shoji T
    Nihon Rinsho; 1990 Feb; 48(2):386-94. PubMed ID: 2329714
    [No Abstract]   [Full Text] [Related]  

  • 15. Temperature of mixed venous blood during exercise.
    Brundin T
    Scand J Clin Lab Invest; 1975 Oct; 35(6):539-43. PubMed ID: 1198057
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new rate-modulated pacemaker system optimized by combination of two sensors.
    Alt E; Theres H; Heinz M; Matula M; Thilo R; Blömer H
    Pacing Clin Electrophysiol; 1988 Aug; 11(8):1119-29. PubMed ID: 2459664
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Central body temperature as a guide to optimal heart rate.
    Griffin JC; Jutzy KR; Claude JP; Knutti JW
    Pacing Clin Electrophysiol; 1983 Mar; 6(2 Pt 2):498-501. PubMed ID: 6189099
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Thermoregulation and central venous coordination of cardiac and respiratory rhythm in the swine. I. Changes in cardiorespiratory functions during cooling and rewarming].
    Sinz R; Sinz V; Hartmann H; Buchholz W; Barth J; Mügge L
    Z Gesamte Inn Med; 1973 May; 28(10):290-8 passim. PubMed ID: 4734035
    [No Abstract]   [Full Text] [Related]  

  • 19. [Stroke volume, central venous oxygen saturation and blood temperature as control parameters of frequency-adapted pacemaker stimulation].
    Stangl K; Wirtzfeld A; Göbl G; Heinze R; Laule M; Hoekstein K
    Z Kardiol; 1987 Feb; 76(2):110-7. PubMed ID: 3577308
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Older adults with type 2 diabetes store more heat during exercise.
    Kenny GP; Stapleton JM; Yardley JE; Boulay P; Sigal RJ
    Med Sci Sports Exerc; 2013 Oct; 45(10):1906-14. PubMed ID: 23542894
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.