These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
199 related articles for article (PubMed ID: 33398794)
1. Validating respiratory index of auto-titrating positive airway pressure device with polysomnography. Park DY; Gu G; Han JG; Park B; Kim HJ Sleep Breath; 2021 Sep; 25(3):1477-1485. PubMed ID: 33398794 [TBL] [Abstract][Full Text] [Related]
2. Validation of the System One RemStar Auto A-Flex for Obstructive Sleep Apnea Treatment and Detection of Residual Apnea-Hypopnea Index: A European Randomized Trial. Gagnadoux F; Pevernagie D; Jennum P; Lon N; Loiodice C; Tamisier R; van Mierlo P; Trzepizur W; Neddermann M; Machleit A; Jasko J; Pépin JL J Clin Sleep Med; 2017 Feb; 13(2):283-290. PubMed ID: 27784415 [TBL] [Abstract][Full Text] [Related]
3. Effective comparison of two auto-CPAP devices for treatment of obstructive sleep apnea based on polysomnographic evaluation. Shi HB; Cheng L; Nakayama M; Kakazu Y; Yin M; Miyoshi A; Komune S Auris Nasus Larynx; 2005 Sep; 32(3):237-41. PubMed ID: 15893440 [TBL] [Abstract][Full Text] [Related]
4. Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report. Morgenthaler TI; Aurora RN; Brown T; Zak R; Alessi C; Boehlecke B; Chesson AL; Friedman L; Kapur V; Maganti R; Owens J; Pancer J; Swick TJ; ; Sleep; 2008 Jan; 31(1):141-7. PubMed ID: 18220088 [TBL] [Abstract][Full Text] [Related]
5. Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine report. Littner M; Hirshkowitz M; Davila D; Anderson WM; Kushida CA; Woodson BT; Johnson SF; Merrill SW; Sleep; 2002 Mar; 25(2):143-7. PubMed ID: 11902424 [TBL] [Abstract][Full Text] [Related]
6. Detection of upper airway status and respiratory events by a current generation positive airway pressure device. Li QY; Berry RB; Goetting MG; Staley B; Soto-Calderon H; Tsai SC; Jasko JG; Pack AI; Kuna ST Sleep; 2015 Apr; 38(4):597-605. PubMed ID: 25409101 [TBL] [Abstract][Full Text] [Related]
7. Polysomnographic determinants of requirement for advanced positive pressure therapeutic options for obstructive sleep apnea. Gupta A; Shukla G Sleep Breath; 2018 May; 22(2):401-409. PubMed ID: 28822020 [TBL] [Abstract][Full Text] [Related]
8. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data. Huang HC; Hillman DR; McArdle N Sleep; 2012 Sep; 35(9):1277-83A. PubMed ID: 22942506 [TBL] [Abstract][Full Text] [Related]
9. Acute effects of autoadjusting and fixed continuous positive airway pressure treatments on cardiorespiratory coupling in obese patients with obstructive sleep apnea. Patruno V; Tobaldini E; Bianchi AM; Mendez MO; Coletti O; Costantino G; Montano N Eur J Intern Med; 2014 Feb; 25(2):164-8. PubMed ID: 24373628 [TBL] [Abstract][Full Text] [Related]
10. Clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea. Kushida CA; Chediak A; Berry RB; Brown LK; Gozal D; Iber C; Parthasarathy S; Quan SF; Rowley JA; ; J Clin Sleep Med; 2008 Apr; 4(2):157-71. PubMed ID: 18468315 [TBL] [Abstract][Full Text] [Related]
11. [Unattended automated titration to determine therapeutic continuous positive airway pressure in patients with obstructive sleep apnea]. Sato K; Hashimoto T Nihon Jibiinkoka Gakkai Kaiho; 2004 May; 107(5):494-9. PubMed ID: 15198010 [TBL] [Abstract][Full Text] [Related]
12. Outcomes of Pediatric Titration Sleep Studies Following Empirical Use of Positive Airway Pressure and the Effect on Adherence to Therapy. Willis LD; Spray BJ; Scribner A; Pruss K; Jambhekar S Respir Care; 2022 Apr; 67(4):464-470. PubMed ID: 35042747 [TBL] [Abstract][Full Text] [Related]
14. Real-world data on polysomnography- and patient-reported outcomes in hypoglossal nerve stimulation and auto-titrating positive airway pressure therapy for obstructive sleep apnea. Pordzik J; Ludwig K; Seifen C; Ruckes C; Huppertz T; Bahr-Hamm K; Hackenberg B; Matthias C; Gouveris H Respir Med; 2024 Oct; 232():107750. PubMed ID: 39084269 [TBL] [Abstract][Full Text] [Related]
15. Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. Berry RB; Budhiraja R; Gottlieb DJ; Gozal D; Iber C; Kapur VK; Marcus CL; Mehra R; Parthasarathy S; Quan SF; Redline S; Strohl KP; Davidson Ward SL; Tangredi MM; J Clin Sleep Med; 2012 Oct; 8(5):597-619. PubMed ID: 23066376 [TBL] [Abstract][Full Text] [Related]
16. Comparison of 3-months treatment adherence and estimating residual apnea hypopnea index between home versus in-laboratory auto-titrating positive airway pressure titration. Aydin Guclu O; Ursavas A; Kasapoglu F; Ocakoglu G; Karadag M Clin Respir J; 2020 Jul; 14(7):622-630. PubMed ID: 32107871 [TBL] [Abstract][Full Text] [Related]
17. Auto-adjusting positive airway pressure treatment for sleep apnea diagnosed by home sleep testing. Berry RB; Sriram P J Clin Sleep Med; 2014 Dec; 10(12):1269-75. PubMed ID: 25348244 [TBL] [Abstract][Full Text] [Related]
18. Reliability of respiratory event detection with continuous positive airway pressure in moderate to severe obstructive sleep apnea - comparison of polysomnography with a device-based analysis. Richter M; Schroeder M; Domanski U; Schwaibold M; Nilius G Sleep Breath; 2023 Aug; 27(4):1639-1650. PubMed ID: 36394692 [TBL] [Abstract][Full Text] [Related]
19. Practical and rapidly-implemented parameters for assessing APAP titration failure. Şahin Duyar S; Fırat S; Kara T; Çelik D Sleep Breath; 2021 Mar; 25(1):49-55. PubMed ID: 32193843 [TBL] [Abstract][Full Text] [Related]
20. Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea. Nigro CA; González S; Arce A; Aragone MR; Nigro L Sleep Breath; 2015 May; 19(2):569-78. PubMed ID: 25115886 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]