BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 3339889)

  • 1. In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps.
    Farrar DJ; Litwak P; Lawson JH; Ward RS; White KA; Robinson AJ; Rodvien R; Hill JD
    J Thorac Cardiovasc Surg; 1988 Feb; 95(2):191-200. PubMed ID: 3339889
    [TBL] [Abstract][Full Text] [Related]  

  • 2. VAD Biomer blood sacs: mechanical tests and ultrastructural observations.
    Bedini R; Chistolini P; De Angelis G; Formisano G; Caiazza S
    Med Prog Technol; 1993; 19(2):83-8. PubMed ID: 8107668
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of three ventricles used for left ventricular bypass in the calf.
    O'Bannon W; Donachy JH; Brighton JA; Phillips WM; Prophet GA; Ferrari O; Pierce WS
    Trans Am Soc Artif Intern Organs; 1976; 22():450-9. PubMed ID: 951865
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Blood compatibility of PEO grafted polyurethane and HEMA/styrene block copolymer surfaces.
    Nojiri C; Okano T; Jacobs HA; Park KD; Mohammad SF; Olsen DB; Kim SW
    J Biomed Mater Res; 1990 Sep; 24(9):1151-71. PubMed ID: 2211743
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemolytic evaluation using polyurethane microcapsule suspensions in circulatory support devices: normalized index of hemolysis comparisons of commercial centrifugal blood pumps.
    Maruyama O; Yamaguchi K; Nishida M; Onoguchi T; Tsutsui T; Jikuya T; Yamane T
    Artif Organs; 2008 Feb; 32(2):146-56. PubMed ID: 18005270
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Artificial circulatory support with textured interior surfaces. A counterintuitive approach to minimizing thromboembolism.
    Rose EA; Levin HR; Oz MC; Frazier OH; Macmanus Q; Burton NA; Lefrak EA
    Circulation; 1994 Nov; 90(5 Pt 2):II87-91. PubMed ID: 7955291
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cast vs extruded Biomer for biomedical applications.
    Lelah MD; Stafford RJ; Lambrecht LK; Young BR; Cooper SL
    Trans Am Soc Artif Intern Organs; 1981; 27():504-10. PubMed ID: 7331119
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thrombus generation within the artificial heart.
    Olsen DB; Unger F; Oster H; Lawson J; Kessler T; Kolff J; Kolff WJ
    J Thorac Cardiovasc Surg; 1975 Aug; 70(2):248-55. PubMed ID: 125371
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical stability of elastomeric polymers for blood pump applications.
    Hayashi K; Takano H; Matsuda T; Umezu M
    J Biomed Mater Res; 1985 Feb; 19(2):179-93. PubMed ID: 4077879
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microtextured materials for circulatory support devices: preliminary studies.
    Zapanta CM; Griffith JW; Hess GD; Doxtater BJ; Khalapyan T; Pae WE; Rosenberg G
    ASAIO J; 2006; 52(1):17-23. PubMed ID: 16436885
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term animal experiments with an intraventricular axial flow blood pump.
    Yamazaki K; Kormos RL; Litwak P; Tagusari O; Mori T; Antaki JF; Kameneva M; Watach M; Gordon L; Mukuo H; Umezu M; Tomioka J; Outa E; Griffith BP; Koyanagai H
    ASAIO J; 1997; 43(5):M696-700. PubMed ID: 9360136
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In-vivo evaluation of the "HIA-VAD": a new German ventricular assist device.
    Rakhorst G; Hensens AG; Verkerke GJ; Blanksma PK; Bom VJ; Elstrodt J; Magielse CP; van der Meer J; Eilers R; Reul H
    Thorac Cardiovasc Surg; 1994 Jun; 42(3):136-40. PubMed ID: 7940482
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prevention of polyurethane valve cusp calcification with covalently attached bisphosphonate diethylamino moieties.
    Alferiev I; Stachelek SJ; Lu Z; Fu AL; Sellaro TL; Connolly JM; Bianco RW; Sacks MS; Levy RJ
    J Biomed Mater Res A; 2003 Aug; 66(2):385-95. PubMed ID: 12889009
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surface and bulk characteristics of a polyether urethane for artificial hearts.
    Boretos JW; Pierce WS; Baier RE; Leroy AF; Donachy HJ
    J Biomed Mater Res; 1975 May; 9(3):327-40. PubMed ID: 170287
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nonfouling biomaterials based on polyethylene oxide-containing amphiphilic triblock copolymers as surface modifying additives: solid state structure of PEO-copolymer/polyurethane blends.
    Tan J; Brash JL
    J Biomed Mater Res A; 2008 Jun; 85(4):862-72. PubMed ID: 17896775
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a disposable maglev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation.
    Someya T; Kobayashi M; Waguri S; Ushiyama T; Nagaoka E; Hijikata W; Shinshi T; Arai H; Takatani S
    Artif Organs; 2009 Sep; 33(9):704-13. PubMed ID: 19775262
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Temporary left heart bypass and total artificial replacement.
    Bücherl ES
    Z Kardiol; 1985; 74 Suppl 6():65-71. PubMed ID: 3913182
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surface modification of poly(ether urethane urea) with modified dehydroepiandrosterone for improved in vivo biostability.
    Christenson EM; Wiggins MJ; Anderson JM; Hiltner A
    J Biomed Mater Res A; 2005 Apr; 73(1):108-15. PubMed ID: 15714496
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nonthrombogenic, adhesive cellular lining for left ventricular assist devices.
    Scott-Burden T; Tock CL; Bosely JP; Clubb FJ; Parnis SM; Schwarz JJ; Engler DA; Frazier OH; Casscells SW
    Circulation; 1998 Nov; 98(19 Suppl):II339-45. PubMed ID: 9852924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Suppression mechanisms for thrombus formation on heparin-immobilized segmented polyurethane-ureas.
    Nojiri C; Okano T; Park KD; Kim SW
    ASAIO Trans; 1988; 34(3):386-98. PubMed ID: 3196537
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.