These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 33404090)

  • 1. Successful jugular implantable defibrillator lead extraction with bidirectional rotational mechanical sheath.
    Migliore F; Falzone PV; Dall'Aglio P; Piazza M; Tarzia V; Gerosa G
    Pacing Clin Electrophysiol; 2021 Mar; 44(3):557-558. PubMed ID: 33404090
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Successful removal of a jugular implantable defibrillator lead with mechanical single-sheath technique.
    Calvagna GM; Evola R; Scardace G; Valsecchi S
    Pacing Clin Electrophysiol; 2012 Sep; 35(9):e258-60. PubMed ID: 21535032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Safety and efficacy of internal transjugular approach for transvenous extraction of implantable cardioverter defibrillator leads.
    Bongiorni MG; Segreti L; Di Cori A; Zucchelli G; Viani S; Paperini L; De Lucia R; Boem A; Levorato D; Soldati E
    Europace; 2014 Sep; 16(9):1356-62. PubMed ID: 24696221
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous extraction of cardiac pacemaker and implantable cardioverter defibrillator leads with evolution mechanical dilator sheath: a single-centre experience.
    Oto A; Aytemir K; Yorgun H; Canpolat U; Kaya EB; Kabakçı G; Tokgözoğlu L; Özkutlu H
    Europace; 2011 Apr; 13(4):543-7. PubMed ID: 21084359
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Safety and efficacy of the new bidirectional rotational Evolution® mechanical lead extraction sheath: results from a multicentre Italian registry.
    Mazzone P; Migliore F; Bertaglia E; Facchin D; Daleffe E; Calzolari V; Crosato M; Melillo F; Peruzza F; Marzi A; Sora N; Della Bella P
    Europace; 2018 May; 20(5):829-834. PubMed ID: 28339758
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The valuable interaction among cardiac surgeon and electrophysiologist for transvenous rotational mechanical lead extraction.
    Migliore F; Tarzia V; Dall'Aglio PB; Falzone PV; De Lazzari M; Bottio T; D'Onofrio A; Padalino M; Vida V; Rosso J; Leoni L; Pittarello D; Bertaglia E; Iliceto S; Gerosa G
    Pacing Clin Electrophysiol; 2022 Jan; 45(1):92-102. PubMed ID: 34699079
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evolution in transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using a mechanical dilator sheath.
    Oto A; Aytemir K; Canpolat U; Yorgun H; Şahiner L; Kaya EB; Kabakçi G; Tokgözoğlu L
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):834-40. PubMed ID: 22486778
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transvenous lead extraction outcomes using a novel hand-powered bidirectional rotational sheath as a first-line extraction tool in a low-volume centre.
    Ksela J; Prevolnik J; Racman M
    Interact Cardiovasc Thorac Surg; 2021 Apr; 32(3):395-401. PubMed ID: 33249479
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction.
    Aytemir K; Yorgun H; Canpolat U; Şahiner ML; Kaya EB; Evranos B; Özer N
    Europace; 2016 Jul; 18(7):1043-8. PubMed ID: 26467403
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Non-functional lead as a cause of detection disturbances in implantable cardioverter-defibrillator].
    Kempa M; Budrejko S; Nowakowski M; Królak T; Daniłowicz-Szymanowicz L; Raczak G
    Kardiol Pol; 2012; 70(10):1073-5. PubMed ID: 23080104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Major predictors of fibrous adherences in transvenous implantable cardioverter-defibrillator lead extraction.
    Segreti L; Di Cori A; Soldati E; Zucchelli G; Viani S; Paperini L; De Lucia R; Coluccia G; Valsecchi S; Bongiorni MG
    Heart Rhythm; 2014 Dec; 11(12):2196-201. PubMed ID: 25111324
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical performance of a new bidirectional rotational mechanical lead extraction sheath.
    Starck CT; Steffel J; Caliskan E; Holubec T; Schoenrath F; Maisano F; Falk V
    Europace; 2016 Feb; 18(2):253-6. PubMed ID: 25995394
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of two types of rotational mechanical dilatator sheath: Evolution
    Cay S; Ozeke O; Ozcan F; Topaloglu S; Aras D
    Pacing Clin Electrophysiol; 2019 Sep; 42(9):1226-1235. PubMed ID: 31257610
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transfemoral snaring and stabilization of pacemaker and defibrillator leads to maintain vascular access during lead extraction.
    Fischer A; Love B; Hansalia R; Mehta D
    Pacing Clin Electrophysiol; 2009 Mar; 32(3):336-9. PubMed ID: 19272063
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pacing and implantable cardioverter-defibrillator transvenous lead extraction.
    Bongiorni MG; Giannola G; Arena G; Soldati E; Bartoli C; Lapira F; Zucchelli G; Di Cori A
    Ital Heart J; 2005 Mar; 6(3):261-6. PubMed ID: 15875518
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extraction of a tunneled jugular defibrillator lead via a superior approach.
    Abi-Saleh B; Chammas E; Harbieh B; Khoury M
    J Med Liban; 2014; 62(2):113-5. PubMed ID: 25011374
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transvenous extraction of pacing and defibrillator leads--a single-centre experience.
    Geselle PJ; Poesen R; Rega F; Koopman P; Nuyens D; Heidbuchel H; Willems R
    Acta Cardiol; 2012 Dec; 67(6):641-8. PubMed ID: 23393934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Percutaneous extraction of stented device leads.
    Baranowski B; Wazni O; Chung R; Martin DO; Rickard J; Tanaka-Esposito C; Bassiouny M; Wilkoff BL
    Heart Rhythm; 2012 May; 9(5):723-7. PubMed ID: 22182497
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Successful defibrillator lead remnant extraction from right ventricle using a steerable transseptal sheath and a basket retriever.
    Raatikainen MJ; Perälä J; Lahtinen J
    Europace; 2009 Sep; 11(9):1238-40. PubMed ID: 19482853
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Extraction of pacemaker and implantable cardioverter defibrillator leads: patient and lead characteristics in relation to the requirement of extraction tools.
    Bracke F; Meijer A; Van Gelder B
    Pacing Clin Electrophysiol; 2002 Jul; 25(7):1037-40. PubMed ID: 12164443
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.