These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 33433099)

  • 1. Metal ion levels in the blood of patients with metal-on-metal hip prostheses.
    Høl PJ; Hallan G; Indrekvam K
    Tidsskr Nor Laegeforen; 2021 Jan; 141(1):. PubMed ID: 33433099
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Effectiveness of Blood Metal Ions in Identifying Patients with Unilateral Birmingham Hip Resurfacing and Corail-Pinnacle Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris.
    Matharu GS; Berryman F; Brash L; Pynsent PB; Treacy RB; Dunlop DJ
    J Bone Joint Surg Am; 2016 Apr; 98(8):617-26. PubMed ID: 27098320
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris: An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants.
    Matharu GS; Berryman F; Judge A; Reito A; McConnell J; Lainiala O; Young S; Eskelinen A; Pandit HG; Murray DW
    J Bone Joint Surg Am; 2017 Sep; 99(18):1532-1539. PubMed ID: 28926382
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
    Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
    Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Can blood metal ion levels be used to identify patients with bilateral Birmingham Hip Resurfacings who are at risk of adverse reactions to metal debris?
    Matharu GS; Berryman F; Brash L; Pynsent PB; Dunlop DJ; Treacy RB
    Bone Joint J; 2016 Nov; 98-B(11):1455-1462. PubMed ID: 27803220
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing 1-year and 10-year whole blood metal ion results following Birmingham hip resurfacing for osteoarthritis.
    Watt Kearns SJ; Bourget-Murray J; Johnston K; Werle J
    Can J Surg; 2022; 65(4):E504-E511. PubMed ID: 35926884
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Careful patient selection together with optimal implant positioning may reduce but does not eliminate the risk of elevated serum cobalt and chrome levels following metal-on-metal hip resurfacing.
    Oxblom A; Hedlund H; Itayem R; Felländer-Tsai L; Vidgren M; Rolfson O; Brismar H
    Hip Int; 2023 Sep; 33(5):872-879. PubMed ID: 36314413
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Long-term changes in blood metal ion levels in patients with hip resurfacing implants: implications for patient surveillance after 10 years follow-up.
    Reito A; Lainiala O; Berryman F; Dunlop DJ; Eskelinen A; Matharu GS
    Hip Int; 2023 Sep; 33(5):864-871. PubMed ID: 35848136
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Systemic toxicity related to metal hip prostheses.
    Bradberry SM; Wilkinson JM; Ferner RE
    Clin Toxicol (Phila); 2014; 52(8):837-47. PubMed ID: 25132471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Revision of Metal-on-metal Hip Prostheses Results in Marked Reduction of Blood Cobalt and Chromium Ion Concentrations.
    Lainiala O; Reito A; Elo P; Pajamäki J; Puolakka T; Eskelinen A
    Clin Orthop Relat Res; 2015 Jul; 473(7):2305-13. PubMed ID: 25623595
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses.
    Nicolli A; Bortoletti I; Maso S; Trevisan A
    Medicina (Kaunas); 2021 Jan; 57(2):. PubMed ID: 33525335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.
    Antoniou J; Zukor DJ; Mwale F; Minarik W; Petit A; Huk OL
    J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():142-8. PubMed ID: 18676949
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Are Females at Greater Risk for Revision Surgery After Hip Resurfacing Arthroplasty With the Articular Surface Replacement Prosthesis?
    Donahue GS; Lindgren V; Galea VP; Madanat R; Muratoglu O; Malchau H
    Clin Orthop Relat Res; 2016 Oct; 474(10):2257-65. PubMed ID: 27121872
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metal ion levels from well-functioning Birmingham Hip Resurfacings decline significantly at ten years.
    Van Der Straeten C; Van Quickenborne D; De Roest B; Calistri A; Victor J; De Smet K
    Bone Joint J; 2013 Oct; 95-B(10):1332-8. PubMed ID: 24078528
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Cobalt/Chromium Ratio Provides Similar Diagnostic Value to a Low Cobalt Threshold in Predicting Adverse Local Tissue Reactions in Patients With Metal-on-Metal Hip Arthroplasty.
    Laaksonen I; Galea VP; Donahue GS; Matuszak SJ; Muratoglu O; Malchau H
    J Arthroplasty; 2018 Sep; 33(9):3020-3024. PubMed ID: 29716769
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term blood metal ion levels and clinical outcome after Birmingham hip arthroplasty.
    Pietiläinen S; Lindström M; Laaksonen I; Venäläinen MS; Lankinen P; Mäkelä KT
    Scand J Surg; 2022; 111(1):14574969211066197. PubMed ID: 35168442
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Blood Metal Ion Levels Have Limited Utility in the Surveillance of Asymptomatic Large-Head Metal-on-Metal Total Hip Arthroplasties.
    Kiran M; Armstrong C; Shivarathre D; Peter VK
    J Arthroplasty; 2017 Dec; 32(12):3685-3688. PubMed ID: 28781016
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Utility of Metal Ion Trends in Predicting Revision in Metal-on-Metal Total Hip Arthroplasty.
    Carlson BC; Bryan AJ; Carrillo-Villamizar NT; Sierra RJ
    J Arthroplasty; 2017 Sep; 32(9S):S214-S219. PubMed ID: 28320566
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Metal ion release: also a concern for ceramic-on-ceramic couplings?
    Beraudi A; Stea S; De Pasquale D; Bordini B; Catalani S; Apostoli P; Toni A
    Hip Int; 2014; 24(4):321-6. PubMed ID: 24817392
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bilateral total hip replacement: periprosthetic pseudotumor collections are more prevalent in metal-on-metal implants compared to non-metal-on-metal ones.
    Slonimsky E; Kushnir T; Kadar A; Menahem A; Grundshtein A; Dekel S; Eshed I
    Acta Radiol; 2016 Apr; 57(4):463-7. PubMed ID: 25940064
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.