These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 33448735)

  • 1. Evaluation of transcutaneous carbon dioxide and saturation monitoring during fiberoptic bronchoscopy.
    Yumrukuz Şenel M; Fırat H; Kurt EB
    Tuberk Toraks; 2020 Dec; 68(4):379-387. PubMed ID: 33448735
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor.
    Bendjelid K; Schütz N; Stotz M; Gerard I; Suter PM; Romand JA
    Crit Care Med; 2005 Oct; 33(10):2203-6. PubMed ID: 16215371
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Changes in oxygen saturation and transcutaneous carbon dioxide and oxygen levels in patients undergoing fibreoptic bronchoscopy.
    Evans EN; Ganeshalingam K; Ebden P
    Respir Med; 1998 May; 92(5):739-42. PubMed ID: 9713633
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Usefulness of transcutaneous PCO2 to assess nocturnal hypoventilation in restrictive lung disorders.
    Georges M; Nguyen-Baranoff D; Griffon L; Foignot C; Bonniaud P; Camus P; Pepin JL; Rabec C
    Respirology; 2016 Oct; 21(7):1300-6. PubMed ID: 27185178
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device.
    Janssens JP; Howarth-Frey C; Chevrolet JC; Abajo B; Rochat T
    Chest; 1998 Mar; 113(3):768-73. PubMed ID: 9515855
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Transcutaneous measurement of partial pressure of carbon dioxide and oxygen saturation: validation of the SenTec monitor].
    Domingo Ch; Canturri E; Luján M; Moreno A; Espuelas H; Marín A
    Arch Bronconeumol; 2006 May; 42(5):246-51. PubMed ID: 16740241
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.
    Pertzov B; Brachfeld E; Unterman A; Gershman E; Abdel-Rahman N; Rosengarten D; Kramer MR
    Lung; 2019 Feb; 197(1):67-72. PubMed ID: 30474708
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcutaneous monitors during one-lung ventilation: are they reliable?
    Chung MR; Lichtor JL; Rangachari K; Roizen MF
    J Cardiothorac Anesth; 1988 Jun; 2(3):313-9. PubMed ID: 17171866
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
    Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
    Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Value of transcutaneous monitoring of CO2 pressure in the diagnosis and treatment of sleep and breathing disorders].
    Liu Y; Dong X; Zhou W; Li J; An P; Zhao L; Gao Z; Han F
    Zhonghua Yi Xue Za Zhi; 2014 Feb; 94(6):408-11. PubMed ID: 24754981
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Fiberoptic bronchoscopy during noninvasive positive-pressure ventilation in patients with chronic obstructive lung disease with hypoxemia and hypercapnia].
    Da Conceiçao M; Genco G; Favier JC; Bidallier I; Pitti R
    Ann Fr Anesth Reanim; 2000 Apr; 19(4):231-6. PubMed ID: 10836106
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcutaneous CO
    Don D; Osterbauer B; Nour S; Matar M; Margolis R; Bushman G
    Laryngoscope; 2021 Jun; 131(6):1410-1415. PubMed ID: 33118646
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection of early nocturnal hypoventilation in neuromuscular disorders.
    Trucco F; Pedemonte M; Fiorillo C; Tan HL; Carlucci A; Brisca G; Tacchetti P; Bruno C; Minetti C
    J Int Med Res; 2018 Mar; 46(3):1153-1161. PubMed ID: 29210305
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparison of the incidence of hypercapnea in non-obese and morbidly obese peri-operative patients using the SenTec transcutaneous pCO(2) monitor.
    Soto RG; Davis M; Faulkner MJ
    J Clin Monit Comput; 2014 Jun; 28(3):293-8. PubMed ID: 24292821
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of end-tidal and transcutaneous PCO2 monitoring during sleep.
    Sanders MH; Kern NB; Costantino JP; Stiller RA; Strollo PJ; Studnicki KA; Coates JA; Richards TJ
    Chest; 1994 Aug; 106(2):472-83. PubMed ID: 7774323
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia.
    Rohling R; Biro P
    J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of hypoventilation during thoracoscopy: combined cutaneous carbon dioxide tension and oximetry monitoring with a new digital sensor.
    Chhajed PN; Kaegi B; Rajasekaran R; Tamm M
    Chest; 2005 Feb; 127(2):585-8. PubMed ID: 15706000
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The effect of different types of anesthetic respirators on oxygenation and ventilation in infants during short-term anesthesia. A study using transcutaneous PO2 and PCO2 monitoring].
    Scheiber G; Hess W; Marichal A
    Anaesthesist; 1994 Aug; 43(8):510-20. PubMed ID: 7978174
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation.
    Aarrestad S; Tollefsen E; Kleiven AL; Qvarfort M; Janssens JP; Skjønsberg OH
    Respir Med; 2016 Mar; 112():112-8. PubMed ID: 26874895
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Carbon dioxide accumulation during analgosedated colonoscopy: comparison of propofol and midazolam.
    Heuss LT; Sugandha SP; Beglinger C
    World J Gastroenterol; 2012 Oct; 18(38):5389-96. PubMed ID: 23082055
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.