164 related articles for article (PubMed ID: 33451908)
1. Neutron dosimetry and shielding verification in commissioning of Compact Proton Therapy Centers (CPTC) using MCNP6.2 Monte Carlo code.
Garcia-Fernandez GF; Gallego E; Gomez-Ros JM; Vega-Carrillo HR; Garcia-Baonza R; Cevallos-Robalino LE; Guzman-Garcia KA
Appl Radiat Isot; 2021 Mar; 169():109279. PubMed ID: 33451908
[TBL] [Abstract][Full Text] [Related]
2. Benchmarking of stray neutron fields produced by synchrocyclotrons and synchrotrons in compact protontherapy centers (CPTC) using MCNP6 Monte Carlo code.
García-Fernandez GF; Gallego E; Gómez-Ros JM; Vega-Carrillo HR; Guzman-García KA; Cevallos-Robalino LE; García-Baonza R; Fuentes Hernández E
Appl Radiat Isot; 2023 Mar; 193():110645. PubMed ID: 36642038
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo characterization and benchmarking of extended range REM meters for its application in shielding and radiation area monitoring in Compact Proton Therapy Centers (CPTC).
García-Fernández GF; Cevallos-Robalino LE; García-Baonza R; Gallego E; Vega-Carrillo HR; Guzman-García KA; Lorente A; Ibáñez S
Appl Radiat Isot; 2019 Oct; 152():115-126. PubMed ID: 31295682
[TBL] [Abstract][Full Text] [Related]
4. Shielding implications for secondary neutrons and photons produced within the patient during IMPT.
DeMarco J; Kupelian P; Santhanam A; Low D
Med Phys; 2013 Jul; 40(7):071701. PubMed ID: 23822405
[TBL] [Abstract][Full Text] [Related]
5. A comprehensive Monte Carlo study of out-of-field secondary neutron spectra in a scanned-beam proton therapy gantry room.
Englbrecht FS; Trinkl S; Mares V; Rühm W; Wielunski M; Wilkens JJ; Hillbrand M; Parodi K
Z Med Phys; 2021 May; 31(2):215-228. PubMed ID: 33622567
[TBL] [Abstract][Full Text] [Related]
6. Radiation shielding assessment of high-energy proton imaging at a proton therapy facility.
Penfold SN
Med Phys; 2022 Aug; 49(8):5340-5346. PubMed ID: 35611603
[TBL] [Abstract][Full Text] [Related]
7. Neutron shielding for a new projected proton therapy facility: A Geant4 simulation study.
Cadini F; Bolst D; Guatelli S; Beltran C; Jackson M; Rosenfeld AB
Phys Med; 2016 Dec; 32(12):1862-1871. PubMed ID: 28024848
[TBL] [Abstract][Full Text] [Related]
8. Shielding verification and neutron dose evaluation of the Mevion S250 proton therapy unit.
Prusator MT; Ahmad S; Chen Y
J Appl Clin Med Phys; 2018 Mar; 19(2):305-310. PubMed ID: 29468842
[TBL] [Abstract][Full Text] [Related]
9. Analytical shielding calculations for a proton therapy facility.
Avery S; Ainsley C; Maughan R; McDonough J
Radiat Prot Dosimetry; 2008; 131(2):167-79. PubMed ID: 18487617
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo simulation of secondary neutron dose for scanning proton therapy using FLUKA.
Lee C; Lee S; Lee SJ; Song H; Kim DH; Cho S; Jo K; Han Y; Chung YH; Kim JS
PLoS One; 2017; 12(10):e0186544. PubMed ID: 29045491
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault.
Zheng Y; Newhauser W; Klein E; Low D
Phys Med Biol; 2009 Nov; 54(22):6943-57. PubMed ID: 19887713
[TBL] [Abstract][Full Text] [Related]
12. Monte Carlo modeling of proton therapy installations: a global experimental method to validate secondary neutron dose calculations.
Farah J; Martinetti F; Sayah R; Lacoste V; Donadille L; Trompier F; Nauraye C; De Marzi L; Vabre I; Delacroix S; Hérault J; Clairand I
Phys Med Biol; 2014 Jun; 59(11):2747-65. PubMed ID: 24800943
[TBL] [Abstract][Full Text] [Related]
13. Off-axis dose equivalent due to secondary neutrons from uniform scanning proton beams during proton radiotherapy.
Islam MR; Collums TL; Zheng Y; Monson J; Benton ER
Phys Med Biol; 2013 Nov; 58(22):8235-51. PubMed ID: 24201018
[TBL] [Abstract][Full Text] [Related]
14. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
[TBL] [Abstract][Full Text] [Related]
15. Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems.
Farah J; Mares V; Romero-Expósito M; Trinkl S; Domingo C; Dufek V; Klodowska M; Kubancak J; Knežević Ž; Liszka M; Majer M; Miljanić S; Ploc O; Schinner K; Stolarczyk L; Trompier F; Wielunski M; Olko P; Harrison RM
Med Phys; 2015 May; 42(5):2572-84. PubMed ID: 25979049
[TBL] [Abstract][Full Text] [Related]
16. Shielding design for a laser-accelerated proton therapy system.
Fan J; Luo W; Fourkal E; Lin T; Li J; Veltchev I; Ma CM
Phys Med Biol; 2007 Jul; 52(13):3913-30. PubMed ID: 17664585
[TBL] [Abstract][Full Text] [Related]
17. Shielding variation effects for 250 MeV protons on tissue targets.
Brandl A; Hranitzky C; Rollet S
Radiat Prot Dosimetry; 2005; 115(1-4):195-9. PubMed ID: 16381711
[TBL] [Abstract][Full Text] [Related]
18. Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments.
Xu X; Yi C; Wanyue T; Yuanming S; Jingbin L; Yumin L; Long Z; Jiaxi L; Xiaoyi L
Health Phys; 2020 Jun; 118(6):600-608. PubMed ID: 31972689
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design.
Titt U; Pera E; Gillin MT
Int J Part Ther; 2020; 6(4):29-37. PubMed ID: 32582817
[TBL] [Abstract][Full Text] [Related]
20. Neutron H*(10) inside a proton therapy facility: comparison between Monte Carlo simulations and WENDI-2 measurements.
De Smet V; Stichelbaut F; Vanaudenhove T; Mathot G; De Lentdecker G; Dubus A; Pauly N; Gerardy I
Radiat Prot Dosimetry; 2014 Oct; 161(1-4):417-21. PubMed ID: 24255173
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]