These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
144 related articles for article (PubMed ID: 33453791)
1. Comprehensive supramolecular solvent-based sample treatment platform for evaluation of combined exposure to mixtures of bisphenols and derivatives by liquid chromatography-tandem mass spectrometry. Caballero-Casero N; Rubio S Anal Chim Acta; 2021 Feb; 1144():14-25. PubMed ID: 33453791 [TBL] [Abstract][Full Text] [Related]
2. Analytical methods for the determination of mixtures of bisphenols and derivatives in human and environmental exposure sources and biological fluids. A review. Caballero-Casero N; Lunar L; Rubio S Anal Chim Acta; 2016 Feb; 908():22-53. PubMed ID: 26826686 [TBL] [Abstract][Full Text] [Related]
3. Quick and simple sample treatment for multiresidue analysis of bisphenols, bisphenol diglycidyl ethers and their derivatives in canned food prior to liquid chromatography and fluorescence detection. Alabi A; Caballero-Casero N; Rubio S J Chromatogr A; 2014 Apr; 1336():23-33. PubMed ID: 24594089 [TBL] [Abstract][Full Text] [Related]
4. Saliva-induced coacervation of inverted aggregates of hexanol for simplifying human biomonitoring: Application to the determination of free bisphenols. Romera-García E; Caballero-Casero N; Rubio S Talanta; 2019 Nov; 204():465-474. PubMed ID: 31357321 [TBL] [Abstract][Full Text] [Related]
5. Analytical method for the biomonitoring of bisphenols and parabens by liquid chromatography coupled to tandem mass spectrometry in human hair. Robin J; Binson G; Albouy M; Sauvaget A; Pierre-Eugène P; Migeot V; Dupuis A; Venisse N Ecotoxicol Environ Saf; 2022 Sep; 243():113986. PubMed ID: 36027714 [TBL] [Abstract][Full Text] [Related]
6. Determination of bisphenols in beverages by mixed-mode solid-phase extraction and liquid chromatography coupled to tandem mass spectrometry. Regueiro J; Wenzl T J Chromatogr A; 2015 Nov; 1422():230-238. PubMed ID: 26525665 [TBL] [Abstract][Full Text] [Related]
7. A dispersive liquid-liquid microextraction based on solidification of floating organic droplet followed by injector port silylation coupled with gas chromatography-tandem mass spectrometry for the determination of nine bisphenols in bottled carbonated beverages. Mandrah K; Satyanarayana GNV; Roy SK J Chromatogr A; 2017 Dec; 1528():10-17. PubMed ID: 29096924 [TBL] [Abstract][Full Text] [Related]
8. Restricted access supramolecular solvents for removal of matrix-induced ionization effects in mass spectrometry: Application to the determination of Fusarium toxins in cereals. García-Fonseca S; Rubio S Talanta; 2016 Feb; 148():370-9. PubMed ID: 26653462 [TBL] [Abstract][Full Text] [Related]
9. Supramolecular solvent-based high-throughput sample treatment platform for the biomonitoring of PAH metabolites in urine by liquid chromatography-tandem mass spectrometry. Martinefski M; Feizi N; Lunar ML; Rubio S Chemosphere; 2019 Dec; 237():124525. PubMed ID: 31549648 [TBL] [Abstract][Full Text] [Related]
10. Concentrations of Bisphenols in Canned Foods and Their Risk Assessment in Korea. Choi SJ; Yun ES; Shin JM; Kim YS; Lee JS; Lee JH; Kim DG; Oh YH; Jung K; Kim GH J Food Prot; 2018 Jun; 81(6):903-916. PubMed ID: 29737868 [TBL] [Abstract][Full Text] [Related]
11. Development and validation of a stable-isotope dilution liquid chromatography-tandem mass spectrometry method for the determination of bisphenols in ready-made meals. Regueiro J; Wenzl T J Chromatogr A; 2015 Oct; 1414():110-21. PubMed ID: 26456223 [TBL] [Abstract][Full Text] [Related]
12. The use of a restricted access volatile supramolecular solvent for the LC/MS-MS assay of bisphenol A in urine with a significant reduction of phospholipid-based matrix effects. Salatti-Dorado JÁ; Caballero-Casero N; Sicilia MD; Lunar ML; Rubio S Anal Chim Acta; 2017 Jan; 950():71-79. PubMed ID: 27916133 [TBL] [Abstract][Full Text] [Related]
13. The dose effect of dansyl chloride on the derivative products of bisphenols and its application for the determination of bisphenols in human serum by high-performance liquid chromatography-tandem mass spectrometry. Guo C; Zhao X; Jin J; Wang L; Tan D; Chen J; Ni Y J Sep Sci; 2021 Aug; 44(16):3052-3060. PubMed ID: 34101988 [TBL] [Abstract][Full Text] [Related]
14. Identification of bisphenols and derivatives in greenhouse dust as a potential source for human occupational exposure. Caballero-Casero N; Rubio S Anal Bioanal Chem; 2022 Jul; 414(18):5397-5409. PubMed ID: 35094115 [TBL] [Abstract][Full Text] [Related]
15. Concentrations and profiles of bisphenol A and other bisphenol analogues in foodstuffs from the United States and their implications for human exposure. Liao C; Kannan K J Agric Food Chem; 2013 May; 61(19):4655-62. PubMed ID: 23614805 [TBL] [Abstract][Full Text] [Related]
16. Recent advances in analysis of bisphenols and their derivatives in biological matrices. Ocaña-Rios I; de Jesús Olmos-Espejel J; Donkor KK Anal Bioanal Chem; 2022 Jan; 414(2):807-846. PubMed ID: 34652496 [TBL] [Abstract][Full Text] [Related]
17. Dispersive micro solid phase extraction (DMSPE) using polymer anion exchange (PAX) as the sorbent followed by UPLC-MS/MS for the rapid determination of four bisphenols in commercial edible oils. Xian Y; Wu Y; Dong H; Guo X; Wang B; Wang L J Chromatogr A; 2017 Sep; 1517():35-43. PubMed ID: 28859891 [TBL] [Abstract][Full Text] [Related]
18. Restricted access supramolecular solvent based magnetic solvent bar liquid-phase microextraction for determination of non-steroidal anti-inflammatory drugs in human serum coupled with high performance liquid chromatography-tandem mass spectrometry. Li X; Huang A; Liao X; Chen J; Xiao Y J Chromatogr A; 2020 Dec; 1634():461700. PubMed ID: 33229009 [TBL] [Abstract][Full Text] [Related]
19. Determination of nine bisphenols in sewage and sludge using dummy molecularly imprinted solid-phase extraction coupled with liquid chromatography tandem mass spectrometry. Sun X; Peng J; Wang M; Wang J; Tang C; Yang L; Lei H; Li F; Wang X; Chen J J Chromatogr A; 2018 Jun; 1552():10-16. PubMed ID: 29678407 [TBL] [Abstract][Full Text] [Related]
20. Development and validation of an analytical methodology based on solvent microextraction and UHPLC-MS/MS for determining bisphenols in honeys from different botanical origins. Martín-Gómez B; Valverde S; Bernal J; Ares AM Food Chem; 2024 Aug; 450():139358. PubMed ID: 38631201 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]