199 related articles for article (PubMed ID: 33474911)
1. [Threshold dynamics of the auditory nerve electrically evoked compound action potential in implanted children].
Kechiyan DK; Bakhshinyan VV; Tavartkiladze GA
Vestn Otorinolaringol; 2020; 85(6):17-22. PubMed ID: 33474911
[TBL] [Abstract][Full Text] [Related]
2. Cochlear Implantation with the CI512 and CI532 Precurved Electrode Arrays: One-Year Speech Recognition and Intraoperative Thresholds of Electrically Evoked Compound Action Potentials.
Videhult Pierre P; Eklöf M; Smeds H; Asp F
Audiol Neurootol; 2019; 24(6):299-308. PubMed ID: 31846976
[TBL] [Abstract][Full Text] [Related]
3. Electrically evoked compound action potential (ECAP) in cochlear implant children: Changes in auditory nerve response in first year of cochlear implant use.
Telmesani LM; Said NM
Int J Pediatr Otorhinolaryngol; 2016 Mar; 82():28-33. PubMed ID: 26857311
[TBL] [Abstract][Full Text] [Related]
4. Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children.
Gordon KA; Papsin BC; Harrison RV
Ear Hear; 2004 Oct; 25(5):447-63. PubMed ID: 15599192
[TBL] [Abstract][Full Text] [Related]
5. [The intraoperative application of neural response telemetry with the nucleus CI24M cochlear implant].
Yang H; Tang J; Cao K; Zhu X; Wang Y; Pan T
Zhonghua Er Bi Yan Hou Ke Za Zhi; 2001 Oct; 36(5):352-6. PubMed ID: 12761943
[TBL] [Abstract][Full Text] [Related]
6. Electrically evoked amplitude modulation following response in cochlear implant candidates: comparison with auditory nerve response telemetry, subjective electrical stimulation, and speech perception.
Hirschfelder A; Gräbel S; Olze H
Otol Neurotol; 2012 Aug; 33(6):968-75. PubMed ID: 22772009
[TBL] [Abstract][Full Text] [Related]
7. Differences between electrically evoked compound action potential (ECAP) and behavioral measures in children with cochlear implants operated in the school age vs. operated in the first years of life.
Vlahović S; Šindija B; Aras I; Glunčić M; Trotić R
Int J Pediatr Otorhinolaryngol; 2012 May; 76(5):731-9. PubMed ID: 22398117
[TBL] [Abstract][Full Text] [Related]
8. Using evoked compound action potentials to assess activation of electrodes and predict C-levels in the Tempo+ cochlear implant speech processor.
Alvarez I; de la Torre A; Sainz M; Roldán C; Schoesser H; Spitzer P
Ear Hear; 2010 Feb; 31(1):134-45. PubMed ID: 19838116
[TBL] [Abstract][Full Text] [Related]
9. Analysis of electrically evoked compound action potential of the auditory nerve in children with bilateral cochlear implants.
Caldas FF; Cardoso CC; Barreto MA; Teixeira MS; Hilgenberg AM; Serra LS; Bahmad Junior F
Braz J Otorhinolaryngol; 2016; 82(2):123-30. PubMed ID: 26727607
[TBL] [Abstract][Full Text] [Related]
10. [Electrically evoked auditory nerve compound action potentials in Nucleus CI24M cochlear implant users].
Zhu X; Cao K; Pan T; Yang H; Wang Y
Lin Chuang Er Bi Yan Hou Ke Za Zhi; 2002 Jan; 16(1):5-8. PubMed ID: 11944479
[TBL] [Abstract][Full Text] [Related]
11. [Electrically evoked compound action potential thresholds of pediatric cochlear implant recipients and its clinical application].
Xi X; Hong MD; Han DY; Huang DL; Yang WY
Zhonghua Er Bi Yan Hou Ke Za Zhi; 2003 Feb; 38(1):43-6. PubMed ID: 12778767
[TBL] [Abstract][Full Text] [Related]
12. [Site of prelingual cochlear stimulation and its effect on electrically evoked compound action potentials and refractory using the Nucleus 24 standard].
Ma RY; Li W; Jiang XJ
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2016 Dec; 30(23):1854-1858. PubMed ID: 29798012
[No Abstract] [Full Text] [Related]
13. Using Neural Response Telemetry to Monitor Physiological Responses to Acoustic Stimulation in Hybrid Cochlear Implant Users.
Abbas PJ; Tejani VD; Scheperle RA; Brown CJ
Ear Hear; 2017; 38(4):409-425. PubMed ID: 28085738
[TBL] [Abstract][Full Text] [Related]
14. Comparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the Advanced Bionics cochlear implant.
Jeon EK; Brown CJ; Etler CP; O'Brien S; Chiou LK; Abbas PJ
J Am Acad Audiol; 2010 Jan; 21(1):16-27. PubMed ID: 20085196
[TBL] [Abstract][Full Text] [Related]
15. Relationship between electrically evoked compound action potential thresholds and behavioral T-levels in implanted children with cochlear nerve deficiency.
Chao X; Wang R; Luo J; Wang H; Fan Z; Xu L
Sci Rep; 2023 Mar; 13(1):4309. PubMed ID: 36922582
[TBL] [Abstract][Full Text] [Related]
16. Packing of the cochleostomy site affects auditory nerve response thresholds in precurved off-stylet cochlear implants.
Gordin A; Papsin B; Gordon K
Otol Neurotol; 2010 Feb; 31(2):204-9. PubMed ID: 20101160
[TBL] [Abstract][Full Text] [Related]
17. Effect of total intravenous vs volatile anesthetics on intraoperatively acquired electrically evoked compound action potential in children undergoing cochlear implant surgery: A randomized prospective study.
Alhowary AA; El-Radaideh K; Al-Rusan A; Hani DB; Khraise W; Al Omari A; Alzoubi F
J Clin Anesth; 2017 Feb; 36():80-83. PubMed ID: 28183580
[TBL] [Abstract][Full Text] [Related]
18. The impact of auditory nerve functional states on the correlations between human and computer decisions for electrically evoked compound action potential threshold.
Li Q; Zhang C; Lu T; Xu C; Sun Z; Fan W; Wang Z; Li S
Int J Pediatr Otorhinolaryngol; 2020 Apr; 131():109866. PubMed ID: 31945736
[TBL] [Abstract][Full Text] [Related]
19. A new approach for the determination of ECAP thresholds.
Hoth S; Spitzer P; Praetorius M
Cochlear Implants Int; 2018 Mar; 19(2):104-114. PubMed ID: 29161976
[TBL] [Abstract][Full Text] [Related]
20. Effect of cochlear implant electrode array design on auditory nerve and behavioral response in children.
Telmesani LM; Said NM
Int J Pediatr Otorhinolaryngol; 2015 May; 79(5):660-5. PubMed ID: 25746517
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]