These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 33483772)

  • 21. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.
    Brockmeyer M; Schmitt C; Haupert A; Kohn D; Lorbach O
    Arch Orthop Trauma Surg; 2017 Dec; 137(12):1719-1724. PubMed ID: 28942510
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effectiveness of diagnostic tests for the assessment of shoulder pain due to soft tissue disorders: a systematic review.
    Dinnes J; Loveman E; McIntyre L; Waugh N
    Health Technol Assess; 2003; 7(29):iii, 1-166. PubMed ID: 14567906
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation.
    Kang CH; Kim SS; Kim JH; Chung KB; Kim YH; Oh YW; Jeong WK; Kim BH
    Skeletal Radiol; 2009 Nov; 38(11):1063-9. PubMed ID: 19543893
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Diagnostic Performance of MR Arthrography with Anterior Trans-Subscapularis versus Posterior Injection Approach for Subscapularis Tendon Tears at 3.0T.
    Jung JY; Jee WH; Chun CW; Kim YS
    Eur Radiol; 2017 Mar; 27(3):1303-1311. PubMed ID: 27311539
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effectiveness of multidetector computed tomography arthrography for the diagnosis of shoulder pathology: comparison with magnetic resonance imaging with arthroscopic correlation.
    Oh JH; Kim JY; Choi JA; Kim WS
    J Shoulder Elbow Surg; 2010 Jan; 19(1):14-20. PubMed ID: 19556150
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A comparison of saline and gadolinium shoulder MR arthrography to arthroscopy.
    Singer AD; Rosenthal J; Umpierrez M; Guo Y; Gonzalez F; Wagner E
    Skeletal Radiol; 2020 Apr; 49(4):625-633. PubMed ID: 31773187
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: accuracy, and inter- and intra-observer agreements.
    Jung JY; Jee WH; Chun HJ; Ahn MI; Kim YS
    Acta Radiol; 2010 Mar; 51(2):194-201. PubMed ID: 20001474
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases.
    Teefey SA; Rubin DA; Middleton WD; Hildebolt CF; Leibold RA; Yamaguchi K
    J Bone Joint Surg Am; 2004 Apr; 86(4):708-16. PubMed ID: 15069134
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Improving the detection of subscapularis tears using a specific transverse CT arthrography image.
    Asmar G; Goubier JN; Falcone MO
    Orthop Traumatol Surg Res; 2020 Oct; 106(6):1107-1111. PubMed ID: 32814672
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of rotator cuff tendon tears: comparison of multidetector CT arthrography and 1.5-T MR arthrography.
    Omoumi P; Bafort AC; Dubuc JE; Malghem J; Vande Berg BC; Lecouvet FE
    Radiology; 2012 Sep; 264(3):812-22. PubMed ID: 22919041
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Diagnostic performance of a 3D double-echo steady-state sequence at 3 T using radial reformats for detecting and grading rotator cuff tears: a pilot diagnostic accuracy study with magnetic resonance imaging and arthroscopic correlation.
    Osterholt AC; Link TW; Abrar DB; Mewes AD; Hufeland M; Schleich C; Bittersohl B
    Acta Radiol; 2023 Oct; 64(10):2768-2776. PubMed ID: 37603569
    [TBL] [Abstract][Full Text] [Related]  

  • 32. MR diagnosis of rotator cuff tears of the shoulder: value of using T2-weighted fat-saturated images.
    Reinus WR; Shady KL; Mirowitz SA; Totty WG
    AJR Am J Roentgenol; 1995 Jun; 164(6):1451-5. PubMed ID: 7754891
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy of magnetic resonance imaging (MRI) for subscapularis tear: a systematic review and meta-analysis of diagnostic studies.
    Malavolta EA; Assunção JH; Gracitelli MEC; Yen TK; Bordalo-Rodrigues M; Ferreira Neto AA
    Arch Orthop Trauma Surg; 2019 May; 139(5):659-667. PubMed ID: 30539284
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Ultrasonography Outperforms Magnetic Resonance Imaging in Diagnosing Partial-Thickness Subscapularis Tear.
    Zhu S; Pu D; Li J; Wu D; Huang W; Hu N; Chen H
    Arthroscopy; 2022 Feb; 38(2):278-284. PubMed ID: 34311005
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Accuracy of office-based ultrasonography of the shoulder for the diagnosis of rotator cuff tears.
    Iannotti JP; Ciccone J; Buss DD; Visotsky JL; Mascha E; Cotman K; Rawool NM
    J Bone Joint Surg Am; 2005 Jun; 87(6):1305-11. PubMed ID: 15930541
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Preoperative Magnetic Resonance Imaging Accurately Detects the Arthroscopic Comma Sign in Subscapularis Tears.
    Atinga A; Dwyer T; Theodoropoulos JS; Dekirmendjian K; Naraghi AM; White LM
    Arthroscopy; 2021 Oct; 37(10):3062-3069. PubMed ID: 33940132
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Diagnostic accuracy of MRI for detection of tears and instability of proximal long head of biceps tendon: an evaluation of 100 shoulders compared with arthroscopy.
    Baptista E; Malavolta EA; Gracitelli MEC; Alvarenga D; Bordalo-Rodrigues M; Ferreira Neto AA; de Barros N
    Skeletal Radiol; 2019 Nov; 48(11):1723-1733. PubMed ID: 30937471
    [TBL] [Abstract][Full Text] [Related]  

  • 38. How reliable are imaging protocols in the diagnosis of subscapularis tears?
    Dirkx G; Pouliart N
    Acta Orthop Belg; 2020 Dec; 86(4):706-710. PubMed ID: 33861920
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of magnetic resonance arthrography with arthroscopy for imaging of shoulder injuries: retrospective study.
    Saqib R; Harris J; Funk L
    Ann R Coll Surg Engl; 2017 Apr; 99(4):271-274. PubMed ID: 27652790
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Diagnostic performance of conventional magnetic resonance imaging for detection and grading of subscapularis tendon tear according to Yoo and Rhee classification system in patients underwent arthroscopic rotator cuff surgery.
    Ahn TR; Yoon YC; Yoo JC; Kim HS; Lee JH
    Skeletal Radiol; 2022 Mar; 51(3):659-668. PubMed ID: 34825259
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.