BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 33492106)

  • 1. A novel partial resuscitative endovascular balloon aortic occlusion device that can be deployed in zone 1 for more than 2 hours with minimal provider titration.
    Kemp MT; Wakam GK; Williams AM; Biesterveld BE; O'Connell RL; Vercruysse CA; Chtraklin K; Russo RM; Alam HB
    J Trauma Acute Care Surg; 2021 Mar; 90(3):426-433. PubMed ID: 33492106
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prolonging the zone 1 aortic occlusion time to 4 hours using a partial resuscitative endovascular balloon in a swine model.
    Ho JW; Jin G; Nguyen J; Keeney-Bonthrone TP; Diaz-Perez DA; Dawood ZS; Kemp MT; Alam JS; Gauger MA; Shaikh A; Chtraklin K; Liu B; Alam HB
    J Trauma Acute Care Surg; 2023 Aug; 95(2S Suppl 1):S129-S136. PubMed ID: 37184494
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Titrate to equilibrate and not exsanguinate! Characterization and validation of a novel partial resuscitative endovascular balloon occlusion of the aorta catheter in normal and hemorrhagic shock conditions.
    Forte DM; Do WS; Weiss JB; Sheldon RR; Kuckelman JP; Eckert MJ; Martin MJ
    J Trauma Acute Care Surg; 2019 Nov; 87(5):1015-1025. PubMed ID: 31135770
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of bilobed partial resuscitative endovascular balloon occlusion of the aorta is logistically superior in prolonged management of a highly lethal aortic injury.
    Zilberman-Rudenko J; Behrens B; McCully B; Dewey EN; Smith SG; Murphy JM; Goodman A; Underwood SJ; Rick EA; Madtson BM; Thompson ME; Glaser JJ; Holcomb JB; Schreiber MA
    J Trauma Acute Care Surg; 2020 Sep; 89(3):464-473. PubMed ID: 32467463
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Not ready for prime time: Intermittent versus partial resuscitative endovascular balloon occlusion of the aorta for prolonged hemorrhage control in a highly lethal porcine injury model.
    Johnson MA; Hoareau GL; Beyer CA; Caples CA; Spruce M; Grayson JK; Neff LP; Williams TK
    J Trauma Acute Care Surg; 2020 Feb; 88(2):298-304. PubMed ID: 31996655
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Partial Resuscitative Endovascular Balloon Occlusion of the Aorta via the Tri-Lobe Balloon Catheter.
    Daniel L; Christopher M; Dominic F; Kaitlin M; Jason B; Matthew M; Matthew E; Jason P
    J Surg Res; 2021 Apr; 260():20-27. PubMed ID: 33316756
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A New Pressure-Regulated, Partial Resuscitative Endovascular Balloon Occlusion of the Aorta Device Achieves Targeted Distal Perfusion.
    White JM; Ronaldi AE; Polcz JE; Spreadborough P; Madurska M; Mares JA; Leung LY; Rasmussen TE
    J Surg Res; 2020 Dec; 256():171-179. PubMed ID: 32707400
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Real-time bedside management and titration of partial resuscitative endovascular balloon occlusion of the aorta without an arterial line: Good for pressure, not for flow!
    Carr MJ; Benham DA; Lee JJ; Calvo RY; Wessels LE; Schrader AJ; Krzyzaniak MJ; Martin MJ
    J Trauma Acute Care Surg; 2021 Apr; 90(4):615-622. PubMed ID: 33405469
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of a novel partial resuscitative endovascular balloon occlusion of the aorta device in a swine hemorrhagic shock model: Fine tuning flow to optimize bleeding control and reperfusion injury.
    Forte DM; Do WS; Weiss JB; Sheldon RR; Kuckelman JP; Cook BA; Levine TC; Eckert MJ; Martin MJ
    J Trauma Acute Care Surg; 2020 Jul; 89(1):58-67. PubMed ID: 32569103
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Partial Resuscitative Endovascular Balloon Occlusion of the Aorta Limits Ischemia-Reperfusion Injury After Simulated Aeromedical Evacuation.
    Singer KE; Wallen TE; Youngs J; Blakeman TC; Schuster RM; Stuever MF; Goodman MD
    J Surg Res; 2023 Mar; 283():118-126. PubMed ID: 36403405
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Next-Generation REBOA (Resuscitative Endovascular Balloon Occlusion of the Aorta) Device Precisely Achieves Targeted Regional Optimization in a Porcine Model of Hemorrhagic Shock.
    Polcz JE; Ronaldi AE; Madurska M; Bedocs P; Leung LY; Burmeister DM; White PW; Rasmussen TE; White JM
    J Surg Res; 2022 Dec; 280():1-9. PubMed ID: 35939866
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endovascular variable aortic control (EVAC) versus resuscitative endovascular balloon occlusion of the aorta (REBOA) in a swine model of hemorrhage and ischemia reperfusion injury.
    Williams TK; Tibbits EM; Hoareau GL; Simon MA; Davidson AJ; DeSoucy ES; Faulconer ER; Grayson JK; Neff LP; Johnson MA
    J Trauma Acute Care Surg; 2018 Sep; 85(3):519-526. PubMed ID: 30142105
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Functional outcome after resuscitative endovascular balloon occlusion of the aorta of the proximal and distal thoracic aorta in a swine model of controlled hemorrhage.
    Long KN; Houston R; Watson JD; Morrison JJ; Rasmussen TE; Propper BW; Arthurs ZM
    Ann Vasc Surg; 2015 Jan; 29(1):114-21. PubMed ID: 25449984
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mitigating Ischemia-Reperfusion Injury Using a Bilobed Partial REBOA Catheter: Controlled Lower-Body Hypotension.
    Necsoiu C; Jordan BS; Choi JH; Moon JJ; Espinoza MD; Gremmer BJ; Batchinsky AI; Cancio LC
    Shock; 2021 Mar; 55(3):396-406. PubMed ID: 32826820
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gastroesophageal resuscitative occlusion of the aorta: Physiologic tolerance in a swine model of hemorrhagic shock.
    Tiba MH; McCracken BM; Colmenero CI; Plott JS; Leander DC; Greer NL; Wang SC; Shih AJ; Eliason JL; Ward KR
    J Trauma Acute Care Surg; 2020 Dec; 89(6):1114-1123. PubMed ID: 33112534
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Partial Resuscitative Endovascular Balloon Occlusion of the Aorta in Swine Model of Hemorrhagic Shock.
    Russo RM; Neff LP; Lamb CM; Cannon JW; Galante JM; Clement NF; Grayson JK; Williams TK
    J Am Coll Surg; 2016 Aug; 223(2):359-68. PubMed ID: 27138649
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The physiology of aortic flow and pressures during partial resuscitative endovascular balloon occlusion of the aorta in a swine model of hemorrhagic shock.
    Marble J; Patel NTP; Lane MR; Williams TK; Neff LP; Johnson MA
    J Trauma Acute Care Surg; 2022 Aug; 93(2S Suppl 1):S94-S101. PubMed ID: 35545802
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extending the golden hour for Zone 1 resuscitative endovascular balloon occlusion of the aorta: Improved survival and reperfusion injury with intermittent versus continuous resuscitative endovascular balloon occlusion of the aorta of the aorta in a porcine severe truncal hemorrhage model.
    Kuckelman JP; Barron M; Moe D; Derickson M; Phillips C; Kononchik J; Lallemand M; Marko S; Eckert M; Martin MJ
    J Trauma Acute Care Surg; 2018 Aug; 85(2):318-326. PubMed ID: 30080780
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Zone 1 REBOA in a combat DCBI swine model does not worsen brain injury.
    Cralley AL; Moore EE; Fox CJ; Kissau D; DeBot M; Schaid TR; Mitra S; Hom P; Fragoso M; Ghasabyan A; Erickson C; D'Alessandro A; Hansen KC; Cohen MJ; Silliman CC; Sauaia A
    Surgery; 2022 Aug; 172(2):751-758. PubMed ID: 35690490
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.
    Davidson AJ; Russo RM; Ferencz SE; Cannon JW; Rasmussen TE; Neff LP; Johnson MA; Williams TK
    J Trauma Acute Care Surg; 2017 Jul; 83(1):139-143. PubMed ID: 28632583
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.