These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
101 related articles for article (PubMed ID: 3349830)
1. Bronchoscopic protected catheter brush for the diagnosis of pulmonary infections. Marquette CH; Ramon P; Courcol R; Wallaert B; Tonnel AB; Voisin C Chest; 1988 Apr; 93(4):746-50. PubMed ID: 3349830 [TBL] [Abstract][Full Text] [Related]
2. A fiberoptic bronchoscopy technique to obtain uncontaminated lower airway secretions for bacterial culture. Wimberley N; Faling LJ; Bartlett JG Am Rev Respir Dis; 1979 Mar; 119(3):337-43. PubMed ID: 375784 [TBL] [Abstract][Full Text] [Related]
3. Reliability of the bronchoscopic protected catheter brush in intubated and ventilated patients. Villers D; Derriennic M; Raffi F; Germaud P; Baron D; Nicolas F; Courtieu AL Chest; 1985 Oct; 88(4):527-30. PubMed ID: 4042703 [TBL] [Abstract][Full Text] [Related]
4. A comparative evaluation of two fiberoptic bronchoscopy catheters: the plugged telescoping catheter versus the single sheathed nonplugged catheter. Joshi JH; Wang KP; de Jongh CA; Newman KA; Wiernik PH; Schimpff SC Am Rev Respir Dis; 1982 Nov; 126(5):860-3. PubMed ID: 7149452 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of two bronchofiberscopic methods of culturing the lower respiratory tract. Hayes DA; McCarthy LC; Friedman M Am Rev Respir Dis; 1980 Aug; 122(2):319-23. PubMed ID: 7416608 [TBL] [Abstract][Full Text] [Related]
6. The telescoping plugged catheter in suspected anaerobic infections. A controlled series. Bordelon JY; Legrand P; Gewin WC; Sanders CV Am Rev Respir Dis; 1983 Sep; 128(3):465-8. PubMed ID: 6351679 [TBL] [Abstract][Full Text] [Related]
7. Reliability of the bronchoscopic protected catheter brush in the diagnosis of pneumonia in mechanically ventilated patients. Rodríguez de Castro F; Solé Violán J; Lafarga Capuz B; Caminero Luna J; González Rodríguez B; Manzano Alonso JL Crit Care Med; 1991 Feb; 19(2):171-5. PubMed ID: 1989754 [TBL] [Abstract][Full Text] [Related]
8. Bacterial cultures of the lower respiratory tract in normal volunteers with and without experimental rhinovirus infection using a plugged double catheter system. Halperin SA; Suratt PM; Gwaltney JM; Gröschel DH; Hendley JO; Eggleston PA Am Rev Respir Dis; 1982 Jun; 125(6):678-80. PubMed ID: 6283968 [TBL] [Abstract][Full Text] [Related]
9. [An evaluation of double-plugged catheter brush system in the diagnosis of pulmonary infection via fiberoptic bronchoscope]. Wang JY Zhonghua Jie He He Hu Xi Za Zhi; 1991 Aug; 14(4):223-4, 255-6. PubMed ID: 1802438 [TBL] [Abstract][Full Text] [Related]
10. [Comparison of the shielded telescoping brush catheter with bronchial lavage in the diagnosis of pulmonary infiltrates]. Bille J; Leuenberger P Schweiz Med Wochenschr; 1985 Sep; 115(39):1350-2. PubMed ID: 4071011 [TBL] [Abstract][Full Text] [Related]
11. Diagnosis of nosocomial pneumonia in mechanically ventilated patients. Comparison of a plugged telescoping catheter with the protected specimen brush. Pham LH; Brun-Buisson C; Legrand P; Rauss A; Verra F; Brochard L; Lemaire F Am Rev Respir Dis; 1991 May; 143(5 Pt 1):1055-61. PubMed ID: 2024814 [TBL] [Abstract][Full Text] [Related]
13. Protected specimen brush in the assessment of ventilator-associated pneumonia. Selection of a certain lung segment for bronchoscopic sampling is unnecessary. Marquette CH; Herengt F; Saulnier F; Nevierre R; Mathieu D; Courcol R; Ramon P Chest; 1993 Jan; 103(1):243-7. PubMed ID: 8417887 [TBL] [Abstract][Full Text] [Related]
14. Bronchoscopic diagnosis of pulmonary infections. Comparison of protected-specimen brush and cytology brush with lung aspirates. Fletcher EC; Mohr JA; Levin DC; Flournoy DJ West J Med; 1983 Mar; 138(3):364-70. PubMed ID: 6858123 [TBL] [Abstract][Full Text] [Related]
15. Diagnosis of nosocomial pneumonia in cancer patients undergoing mechanical ventilation: a prospective comparison of the plugged telescoping catheter with the protected specimen brush. Casetta M; Blot F; Antoun S; Leclercq B; Tancrède C; Doyon F; Nitenberg G Chest; 1999 Jun; 115(6):1641-5. PubMed ID: 10378562 [TBL] [Abstract][Full Text] [Related]
16. Blind use of the double-lumen plugged catheter for diagnosis of respiratory tract infections in critically ill children. Zucker A; Pollack M; Katz R Crit Care Med; 1984 Oct; 12(10):867-70. PubMed ID: 6488826 [TBL] [Abstract][Full Text] [Related]
17. [A comparison of the blind double-lumen plugged telescoping catheter with protected specimen brush for the diagnosis of ventilator-associated pneumonia.]. Liu RZ; Xu DX; Sun RL; Li L Zhonghua Jie He He Hu Xi Za Zhi; 2009 Dec; 32(12):915-8. PubMed ID: 20193351 [TBL] [Abstract][Full Text] [Related]
18. Airways microbial flora in COPD patients in stable clinical conditions and during exacerbations: a bronchoscopic investigation. Pela R; Marchesani F; Agostinelli C; Staccioli D; Cecarini L; Bassotti C; Sanguinetti CM Monaldi Arch Chest Dis; 1998 Jun; 53(3):262-7. PubMed ID: 9785808 [TBL] [Abstract][Full Text] [Related]