These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 33514243)

  • 1. Compact scanning retarding potential analyzer.
    Goebel DM; Becatti G
    Rev Sci Instrum; 2021 Jan; 92(1):013511. PubMed ID: 33514243
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High resolution energy analyzer for broad ion beam characterization.
    Kanarov V; Siegfried D; Sferlazzo P; Hayes A; Yevtukhov R
    Rev Sci Instrum; 2008 Sep; 79(9):093304. PubMed ID: 19044404
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A retarding potential analyzer design for keV-level ion thruster beams.
    Zhang Z; Tang H; Zhang Z; Wang J; Cao S
    Rev Sci Instrum; 2016 Dec; 87(12):123510. PubMed ID: 28040974
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magnetized retarding field energy analyzer measuring the particle flux and ion energy distribution of both positive and negative ions.
    Rafalskyi D; Dudin S; Aanesland A
    Rev Sci Instrum; 2015 May; 86(5):053302. PubMed ID: 26026517
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a high dynamic range retarding potential analyzer for electric propulsion plume diagnosis.
    Maystrenko D; Shagayda A; Kravchenko D; Lovtsov A
    Rev Sci Instrum; 2022 Jul; 93(7):073504. PubMed ID: 35922286
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-Performance Compact Pre-Lens Retarding Field Energy Analyzer for Energy Distribution Measurements of an Electron Gun.
    Lee HR; Hwang J; Ogawa T; Jung H; Yun DJ; Lee S; Park IY
    Microsc Microanal; 2022 Sep; ():1-9. PubMed ID: 36062359
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retarding field energy analyzer for the Saskatchewan Torus-Modified plasma boundary.
    Dreval M; Rohraff D; Xiao C; Hirose A
    Rev Sci Instrum; 2009 Oct; 80(10):103505. PubMed ID: 19895062
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A proximal retarding field analyzer for scanning probe energy loss spectroscopy.
    Bauer K; Murphy S; Palmer RE
    Nanotechnology; 2017 Mar; 28(10):105711. PubMed ID: 28082730
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design of a retarding potential grid system for a neutral particle analyzer.
    Titus JB; Anderson JK; Reusch JA; Mezonlin ED
    Rev Sci Instrum; 2014 Nov; 85(11):11D402. PubMed ID: 25430165
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Retarding field analyzer for ion energy distribution measurements at a radio-frequency biased electrode.
    Gahan D; Dolinaj B; Hopkins MB
    Rev Sci Instrum; 2008 Mar; 79(3):033502. PubMed ID: 18377005
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of retarding field energy analyzer transmission by simulation of ion trajectories.
    van de Ven THM; de Meijere CA; van der Horst RM; van Kampen M; Banine VY; Beckers J
    Rev Sci Instrum; 2018 Apr; 89(4):043501. PubMed ID: 29716357
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An ion thruster internal discharge chamber electrostatic probe diagnostic technique using a high-speed probe positioning system.
    Herman DA; Gallimore AD
    Rev Sci Instrum; 2008 Jan; 79(1):013302. PubMed ID: 18248026
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Scanning retarding field analyzer for plasma profile measurements in the boundary of the Alcator C-Mod tokamak.
    Brunner D; LaBombard B; Ochoukov R; Whyte D
    Rev Sci Instrum; 2013 Mar; 84(3):033502. PubMed ID: 23556816
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Retarding field energy analyzer for high energy pulsed electron beam measurements.
    Hu J; Rovey JL; Zhao W
    Rev Sci Instrum; 2017 Jan; 88(1):013302. PubMed ID: 28147681
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The gridded retarding ion drift sensor for the petitSat cubeSat mission.
    Davidson RL; Oborn B; Robertson EF; Noel S; Earle GD; Green J; Kramer J
    Rev Sci Instrum; 2020 Jun; 91(6):064502. PubMed ID: 32611012
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relative calibration of a retarding field energy analyzer sensor array for spatially resolved measurements of the ion flux and ion energy in low temperature plasmas.
    Ries S; Schroeder M; Woestefeld M; Corbella C; Korolov I; Awakowicz P; Schulze J
    Rev Sci Instrum; 2021 Oct; 92(10):103503. PubMed ID: 34717414
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A hybrid electrostatic retarding potential analyzer for the measurement of plasmas at extremely high energy resolution.
    Collinson GA; Chornay DJ; Glocer A; Paschalidis N; Zesta E
    Rev Sci Instrum; 2018 Nov; 89(11):113306. PubMed ID: 30501327
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ion temperature fluctuation measurements using a retarding field analyzer.
    Nedzelskiy IS; Silva C; Duarte P; Fernandes H
    Rev Sci Instrum; 2011 Apr; 82(4):043505. PubMed ID: 21529006
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retarding field analyzer for the EAST plasma boundary.
    Li YL; Xu GS; Xiao C; Wang HQ; Yan N; Wan BN; Chen L; Liu YL; Zhang H; Zhang W; Wang L; Hu GH; Chen R; Xu JC; Ye Y; Li J
    Rev Sci Instrum; 2016 Dec; 87(12):123503. PubMed ID: 28040924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wide-angle display-type retarding field analyzer with high energy and angular resolutions.
    Muro T; Ohkochi T; Kato Y; Izumi Y; Fukami S; Fujiwara H; Matsushita T
    Rev Sci Instrum; 2017 Dec; 88(12):123106. PubMed ID: 29289222
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.