These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 3351749)

  • 1. Comparison of the SRK II formula and other second generation formulas.
    Sanders DR; Retzlaff J; Kraff MC
    J Cataract Refract Surg; 1988 Mar; 14(2):136-41. PubMed ID: 3351749
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the SRK/T formula and other theoretical and regression formulas.
    Sanders DR; Retzlaff JA; Kraff MC; Gimbel HV; Raanan MG
    J Cataract Refract Surg; 1990 May; 16(3):341-6. PubMed ID: 2355322
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length.
    Miraftab M; Hashemi H; Fotouhi A; Khabazkhoob M; Rezvan F; Asgari S
    Middle East Afr J Ophthalmol; 2014; 21(4):307-11. PubMed ID: 25371635
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new posterior chamber intraocular lens formula for axial myopes.
    Thompson JT; Maumenee AE; Baker CC
    Ophthalmology; 1984 May; 91(5):484-8. PubMed ID: 6739051
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Intraocular lens power calculation for short eye].
    Kora Y; Nishihara H; Inatomi M; Koide R; Ozawa T; Kaneko M
    Nippon Ganka Gakkai Zasshi; 1995 Oct; 99(10):1186-9. PubMed ID: 8533644
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.
    Özcura F; Aktaş S; Sağdık HM; Tetikoğlu M
    Int Ophthalmol; 2016 Oct; 36(5):707-12. PubMed ID: 26854320
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Intraocular lens power calculation for high myopic eyes with cataract: comparison of three formulas].
    Zhu XJ; He WW; Du Y; Qian DJ; Dai JH; Lu Y
    Zhonghua Yan Ke Za Zhi; 2017 Apr; 53(4):260-265. PubMed ID: 28412798
    [No Abstract]   [Full Text] [Related]  

  • 8. [An intraocular lens power calculation for high myopia].
    Kora Y; Kitazato T; Inatomi M; Koide R; Yaguchi S; Ozawa T; Kaneko M
    Nippon Ganka Gakkai Zasshi; 1995 Jun; 99(6):692-5. PubMed ID: 7611007
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The analysis of refractive error of long axial high myopic eyes after IOL implantation].
    Zheng Q; Zhao Z; Lian H; Zhao Y
    Zhonghua Yan Ke Za Zhi; 2015 Apr; 51(4):276-81. PubMed ID: 26081231
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Phacoemulsification, capsulorhexis, and intraocular lens power prediction accuracy.
    Olsen T; Gimbel H
    J Cataract Refract Surg; 1993 Nov; 19(6):695-9. PubMed ID: 8271164
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Achieving emmetropia in extremely short eyes with two piggyback posterior chamber intraocular lenses.
    Holladay JT; Gills JP; Leidlein J; Cherchio M
    Ophthalmology; 1996 Jul; 103(7):1118-23. PubMed ID: 8684803
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas.
    Jeong J; Song H; Lee JK; Chuck RS; Kwon JW
    BMC Ophthalmol; 2017 May; 17(1):62. PubMed ID: 28464806
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical evaluation of the Holladay and SRK II formulas.
    Richards SC; Steen DW
    J Cataract Refract Surg; 1990 Jan; 16(1):71-4. PubMed ID: 2299578
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes.
    Olsen T; Thim K; Corydon L
    J Cataract Refract Surg; 1991 Mar; 17(2):187-93. PubMed ID: 2040976
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of fellow eye data in the calculation of intraocular lens power for the second eye.
    Olsen T
    Ophthalmology; 2011 Sep; 118(9):1710-5. PubMed ID: 21723613
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of intraocular lens power calculation formulae in children less than two years.
    Kekunnaya R; Gupta A; Sachdeva V; Rao HL; Vaddavalli PK; Om Prakash V
    Am J Ophthalmol; 2012 Jul; 154(1):13-19.e2. PubMed ID: 22336039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An improved universal theoretical formula for intraocular lens power prediction.
    Barrett GD
    J Cataract Refract Surg; 1993 Nov; 19(6):713-20. PubMed ID: 8271166
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Clinical evaluation of modifications of the SRK formula].
    Matsuo K; Kohama S; Miyata N
    Nippon Ganka Gakkai Zasshi; 1991 Apr; 95(4):377-85. PubMed ID: 1877412
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Selection of IOL power formula for patients with cataract and high myopia].
    Tang P; Pan YC
    Zhonghua Yan Ke Za Zhi; 2003 May; 39(5):290-3. PubMed ID: 12892606
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas.
    Sanders D; Retzlaff J; Kraff M; Kratz R; Gills J; Levine R; Colvard M; Weisel J; Loyd T
    J Am Intraocul Implant Soc; 1981; 7(4):337-40. PubMed ID: 7349649
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.