These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 33517721)

  • 1. Intramedullary nailing of extra-articular distal tibial fractures.
    Hadeed MM; Prakash H; Yarboro SR; Weiss DB
    Bone Joint J; 2021 Feb; 103-B(2):294-298. PubMed ID: 33517721
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing.
    Chan DS; Nayak AN; Blaisdell G; James CR; Denard A; Miles J; Santoni BG
    J Orthop Trauma; 2015 Feb; 29(2):98-104. PubMed ID: 25072288
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
    Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
    Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
    Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
    Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Proper Distal Placement of Tibial Nail Improves Rate of Malalignment for Distal Tibia Fractures.
    Triantafillou K; Barcak E; Villarreal A; Collinge C; Perez E
    J Orthop Trauma; 2017 Dec; 31(12):e407-e411. PubMed ID: 28742786
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Are extra locking bolts or fibular plating more important in extreme nailing of distal tibia fractures? A cadaveric biomechanical analysis.
    Cunningham DJ; Lawrence JE; Kovvur M; Turner KE; Oppizzi G; Xu D; Zhang LQ; Johnson DJ; Mittwede P; Sepehri A; Brand J; O'Toole RV; Gage MJ
    Injury; 2024 Jun; 55(6):111540. PubMed ID: 38622039
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fixation of Proximal Tibial Fractures with Intramedullary Nail and Immediate Weightbearing: A Beneficial Alternative.
    Force A; Tarpada S; Follett L; Dedhia N; Dimitroulias A; Sen MK
    Injury; 2024 Jun; 55(6):111530. PubMed ID: 38637188
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Distal Locking Screws for Intramedullary Nailing of Tibial Fractures.
    Agathangelidis F; Petsatodis G; Kirkos J; Papadopoulos P; Karataglis D; Christodoulou A
    Orthopedics; 2016; 39(2):e253-8. PubMed ID: 26840700
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Elastic intramedullary nailing of the tibia with the Marchetti-Vicenzi nail. 43 treated cases].
    Benmansour MB; Gottin M; Rouvillain JL; Larosa G; Dib C; Dintimille H; Catonné Y
    Rev Chir Orthop Reparatrice Appar Mot; 1999 Jun; 85(3):267-76. PubMed ID: 10422132
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of fracture obliquity and interlocking nail screw configuration on interfragmentary motion in distal metaphyseal tibia fractures.
    Lowenberg DW; DeBaun MR; Sox-Harris A; Behn A
    Eur J Orthop Surg Traumatol; 2020 Feb; 30(2):343-350. PubMed ID: 31571003
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail.
    Henley MB; Meier M; Tencer AF
    J Orthop Trauma; 1993; 7(4):311-9. PubMed ID: 8377039
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing.
    Lowenberg DW; DeBaun MR; Behn A; Sox-Harris A
    Eur J Orthop Surg Traumatol; 2020 Oct; 30(7):1205-1213. PubMed ID: 32367222
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Angular stable locking in a novel intramedullary nail improves construct stability in a distal tibia fracture model.
    Zderic I; Gueorguiev B; Blauth M; Weber A; Koch R; Dauwe J; Schader JF; Stoffel K; Finkemeier C; Hessmann M
    Injury; 2022 Mar; 53(3):878-884. PubMed ID: 34782117
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiographic and clinical outcomes of distal tibia fractures (3-12 cm proximal to the plafond): Comparison of two intramedullary nailing.
    Koca H; Duman S; Sağlam N
    Ulus Travma Acil Cerrahi Derg; 2022 May; 28(5):686-692. PubMed ID: 35485463
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modified tibial nails for treating distal tibia fractures.
    Gorczyca JT; McKale J; Pugh K; Pienkowski D
    J Orthop Trauma; 2002 Jan; 16(1):18-22. PubMed ID: 11782627
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A New Technique for Placement of Blocking Screws and its Mechanical Effect on Stability of Tibia Fractures with Distal Fragments after Insertion of Small-Diameter Intramedullary Nails.
    Zhang CM; Sun L; Wang Q; Huang Q; Lin H; Duan N; Zhang CC; Ma T; Xue HZ; Zhang K; Li Z
    Orthop Surg; 2021 Oct; 13(7):2127-2136. PubMed ID: 34596359
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail.
    Brumback RJ; Toal TR; Murphy-Zane MS; Novak VP; Belkoff SM
    J Bone Joint Surg Am; 1999 Nov; 81(11):1538-44. PubMed ID: 10565645
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.