These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
318 related articles for article (PubMed ID: 33524584)
1. Measuring functional connectivity with wearable MEG. Boto E; Hill RM; Rea M; Holmes N; Seedat ZA; Leggett J; Shah V; Osborne J; Bowtell R; Brookes MJ Neuroimage; 2021 Apr; 230():117815. PubMed ID: 33524584 [TBL] [Abstract][Full Text] [Related]
2. Precision magnetic field modelling and control for wearable magnetoencephalography. Rea M; Holmes N; Hill RM; Boto E; Leggett J; Edwards LJ; Woolger D; Dawson E; Shah V; Osborne J; Bowtell R; Brookes MJ Neuroimage; 2021 Nov; 241():118401. PubMed ID: 34273527 [TBL] [Abstract][Full Text] [Related]
3. Wireless optically pumped magnetometer MEG. Cheng H; He K; Li C; Ma X; Zheng F; Xu W; Liao P; Yang R; Li D; Qin L; Na S; Lyu B; Gao JH Neuroimage; 2024 Oct; 300():120864. PubMed ID: 39322096 [TBL] [Abstract][Full Text] [Related]
4. Multi-channel whole-head OPM-MEG: Helmet design and a comparison with a conventional system. Hill RM; Boto E; Rea M; Holmes N; Leggett J; Coles LA; Papastavrou M; Everton SK; Hunt BAE; Sims D; Osborne J; Shah V; Bowtell R; Brookes MJ Neuroimage; 2020 Oct; 219():116995. PubMed ID: 32480036 [TBL] [Abstract][Full Text] [Related]
5. Measurement of Frontal Midline Theta Oscillations using OPM-MEG. Rhodes N; Rea M; Boto E; Rier L; Shah V; Hill RM; Osborne J; Doyle C; Holmes N; Coleman SC; Mullinger K; Bowtell R; Brookes MJ Neuroimage; 2023 May; 271():120024. PubMed ID: 36918138 [TBL] [Abstract][Full Text] [Related]
6. Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography. Boto E; Seedat ZA; Holmes N; Leggett J; Hill RM; Roberts G; Shah V; Fromhold TM; Mullinger KJ; Tierney TM; Barnes GR; Bowtell R; Brookes MJ Neuroimage; 2019 Nov; 201():116099. PubMed ID: 31419612 [TBL] [Abstract][Full Text] [Related]
7. Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system. Brookes MJ; Boto E; Rea M; Shah V; Osborne J; Holmes N; Hill RM; Leggett J; Rhodes N; Bowtell R Neuroimage; 2021 Aug; 236():118025. PubMed ID: 33838266 [TBL] [Abstract][Full Text] [Related]
8. A 20-channel magnetoencephalography system based on optically pumped magnetometers. Borna A; Carter TR; Goldberg JD; Colombo AP; Jau YY; Berry C; McKay J; Stephen J; Weisend M; Schwindt PDD Phys Med Biol; 2017 Nov; 62(23):8909-8923. PubMed ID: 29035875 [TBL] [Abstract][Full Text] [Related]
9. A 90-channel triaxial magnetoencephalography system using optically pumped magnetometers. Rea M; Boto E; Holmes N; Hill R; Osborne J; Rhodes N; Leggett J; Rier L; Bowtell R; Shah V; Brookes MJ Ann N Y Acad Sci; 2022 Nov; 1517(1):107-124. PubMed ID: 36065147 [TBL] [Abstract][Full Text] [Related]
10. Transforming and comparing data between standard SQUID and OPM-MEG systems. Marhl U; Jodko-Władzińska A; Brühl R; Sander T; Jazbinšek V PLoS One; 2022; 17(1):e0262669. PubMed ID: 35045107 [TBL] [Abstract][Full Text] [Related]
11. Non-rigid-registration-based positioning and labelling of triaxial OPMs on a flexible cap for wearable magnetoencephalography. Gu W; Li D; Gao JH J Neurosci Methods; 2024 Jan; 401():110010. PubMed ID: 37956928 [TBL] [Abstract][Full Text] [Related]
12. Using optically pumped magnetometers to replicate task-related responses in next generation magnetoencephalography. Safar K; Vandewouw MM; Sato J; Devasagayam J; Hill RM; Rea M; Brookes MJ; Taylor MJ Sci Rep; 2024 Mar; 14(1):6513. PubMed ID: 38499615 [TBL] [Abstract][Full Text] [Related]
13. Expanding the clinical application of OPM-MEG using an effective automatic suppression method for the dental brace metal artifact. Wang R; Fu K; Zhao R; Wang D; Yang Z; Bin W; Gao Y; Ning X Neuroimage; 2024 Aug; 296():120661. PubMed ID: 38838840 [TBL] [Abstract][Full Text] [Related]
14. Measuring Human Auditory Evoked Fields with a Flexible Multi-Channel OPM-Based MEG System. Zhang X; Chang Y; Wang H; Zhang Y; Hu T; Feng XY; Zhang MK; Yao ZK; Chen CQ; Xu JY; Fu FY; Guo QQ; Zhu JB; Xie HQ; Yang XD J Integr Neurosci; 2024 Apr; 23(5):93. PubMed ID: 38812381 [TBL] [Abstract][Full Text] [Related]
15. Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System. Borna A; Carter TR; Colombo AP; Jau YY; McKay J; Weisend M; Taulu S; Stephen JM; Schwindt PDD PLoS One; 2020; 15(1):e0227684. PubMed ID: 31978102 [TBL] [Abstract][Full Text] [Related]
16. Wearable OPM-MEG: A changing landscape for epilepsy. Pedersen M; Abbott DF; Jackson GD Epilepsia; 2022 Nov; 63(11):2745-2753. PubMed ID: 35841260 [TBL] [Abstract][Full Text] [Related]
17. Triaxial detection of the neuromagnetic field using optically-pumped magnetometry: feasibility and application in children. Boto E; Shah V; Hill RM; Rhodes N; Osborne J; Doyle C; Holmes N; Rea M; Leggett J; Bowtell R; Brookes MJ Neuroimage; 2022 May; 252():119027. PubMed ID: 35217205 [TBL] [Abstract][Full Text] [Related]
18. Cross-Axis projection error in optically pumped magnetometers and its implication for magnetoencephalography systems. Borna A; Iivanainen J; Carter TR; McKay J; Taulu S; Stephen J; Schwindt PDD Neuroimage; 2022 Feb; 247():118818. PubMed ID: 34915157 [TBL] [Abstract][Full Text] [Related]
19. A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers. Schofield H; Hill RM; Feys O; Holmes N; Osborne J; Doyle C; Bobela D; Corvilian P; Wens V; Rier L; Bowtell R; Ferez M; Mullinger KJ; Coleman S; Rhodes N; Rea M; Tanner Z; Boto E; de Tiège X; Shah V; Brookes MJ bioRxiv; 2024 Mar; ():. PubMed ID: 38558964 [TBL] [Abstract][Full Text] [Related]
20. Magnetoencephalography with optically pumped magnetometers (OPM-MEG): the next generation of functional neuroimaging. Brookes MJ; Leggett J; Rea M; Hill RM; Holmes N; Boto E; Bowtell R Trends Neurosci; 2022 Aug; 45(8):621-634. PubMed ID: 35779970 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]