These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 33525305)

  • 1. Poller blocking screw augmentation to treat delayed union of proximal tibial shaft fracture after locked IM nailing.
    Ferreli A; Nonne D; Russo A; Dessì G; Marongiu G
    Acta Biomed; 2021 Jan; 91(4):e2020119. PubMed ID: 33525305
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Do Poller screws effect union in tibial shaft fractures treated with intramedullary nailing?
    Peat F; Ordas-Bayon A; Krkovic M
    Injury; 2021 Oct; 52(10):3132-3138. PubMed ID: 33627250
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Outcome Analysis of Intramedullary Nailing Augmented with Poller Screws for Treating Difficult Reduction Fractures of Femur and Tibia: a Retrospective Cohort Study.
    Guo J; Zha J; Di J; Yin Y; Hou Z; Zhang Y
    Biomed Res Int; 2021; 2021():6615776. PubMed ID: 33869628
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws.
    Ricci WM; O'Boyle M; Borrelli J; Bellabarba C; Sanders R
    J Orthop Trauma; 2001 May; 15(4):264-70. PubMed ID: 11371791
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technique for precise placement of poller screws with intramedullary nailing of metaphyseal fractures of the femur and the tibia.
    Shahulhameed A; Roberts CS; Ojike NI
    Injury; 2011 Feb; 42(2):136-9. PubMed ID: 20488439
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Poller Screw Technique: A Method of Fine-Tuning the Reduction in Locked Nailing.
    Koller T; Mühlebach J; Livingston A; Boopalan PRJVC; Iselin LD
    J Foot Ankle Surg; 2020; 59(3):638-640. PubMed ID: 32354521
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fixation of distal tibia fracture through plating, nailing, and nailing with Poller screws: A comparative biomechanical-based experimental and numerical investigation.
    Baseri A; Bagheri MA; Rouhi G; Aghighi MR; Bagheri N
    Proc Inst Mech Eng H; 2020 Oct; 234(10):1129-1138. PubMed ID: 32650692
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Nail Dynamization for Delayed Union and Nonunion in Femur and Tibia Fractures.
    Vaughn J; Gotha H; Cohen E; Fantry AJ; Feller RJ; Van Meter J; Hayda R; Born CT
    Orthopedics; 2016 Nov; 39(6):e1117-e1123. PubMed ID: 27575039
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Elastic intramedullary nailing of the tibia with the Marchetti-Vicenzi nail. 43 treated cases].
    Benmansour MB; Gottin M; Rouvillain JL; Larosa G; Dib C; Dintimille H; Catonné Y
    Rev Chir Orthop Reparatrice Appar Mot; 1999 Jun; 85(3):267-76. PubMed ID: 10422132
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Suprapatellar intramedullary nail combined with screw fixation has comparable surgical outcomes to minimally invasive locking plate fixation in ipsilateral tibial plateau and shaft fractures.
    Lim S; Song HK; Kim TH; Park DY; Lee JW; Chung JY
    Arch Orthop Trauma Surg; 2024 Feb; 144(2):673-681. PubMed ID: 38032381
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intramedullary nailing supplemented with Poller screws for proximal tibial fractures.
    Kulkarni SG; Varshneya A; Kulkarni S; Kulkarni GS; Kulkarni MG; Kulkarni VS; Kulkarni RM
    J Orthop Surg (Hong Kong); 2012 Dec; 20(3):307-11. PubMed ID: 23255635
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Permanent reduction plate and intramedullary nailing of open tibia fractures: Do we need to take them out?
    Revak T; Mahle P; Nicolaou D; Watson JT
    Injury; 2021 Aug; 52(8):2439-2443. PubMed ID: 33879336
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails.
    Krettek C; Stephan C; Schandelmaier P; Richter M; Pape HC; Miclau T
    J Bone Joint Surg Br; 1999 Nov; 81(6):963-8. PubMed ID: 10615966
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Exchange nailing with enhanced distal fixation is effective for the treatment of infraisthmal femoral nonunions.
    Kim JW; Yoon YC; Oh CW; Han SB; Sim JA; Oh JK
    Arch Orthop Trauma Surg; 2018 Jan; 138(1):27-34. PubMed ID: 28956142
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Combination of intramedullary nail and covered screw osteosynthesis for managing distal tibial fracture with ankle joint involvement].
    Rzesacz EH; Könneker W; Reilmann H; Culemann U
    Unfallchirurg; 1998 Dec; 101(12):907-13. PubMed ID: 10025240
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Complications and subsequent surgery after intra-medullary nailing for tibial shaft fractures: Review of 8110 patients.
    Hendrickx LAM; Virgin J; van den Bekerom MPJ; Doornberg JN; Kerkhoffs GMMJ; Jaarsma RL
    Injury; 2020 Jul; 51(7):1647-1654. PubMed ID: 32360087
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Treatment of complex fractures of the ankle and their sequellae using trans-plantar intramedullary nailing].
    Gagneux E; Gerard F; Garbuio P; Vichard P
    Acta Orthop Belg; 1997 Dec; 63(4):294-304. PubMed ID: 9479784
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Augmentation plating leaving the nail in situ is an excellent option for treating femoral shaft nonunion after IM nailing: a multicentre study.
    Uliana CS; Bidolegui F; Kojima K; Giordano V
    Eur J Trauma Emerg Surg; 2021 Dec; 47(6):1895-1901. PubMed ID: 32107562
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prediction of delayed union of tibial shaft fracture treated with intramedullary nailing: multicenter-study analysis and literature review -the TRON study.
    Kawasaki N; Takegami Y; Sakai R; Todoroki K; Uemi R; Imagama S;
    Eur J Orthop Surg Traumatol; 2022 Jan; 32(1):129-135. PubMed ID: 33760997
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A forward-striking technique for reducing fracture gaps during intramedullary nailing: A technical note with clinical results.
    Lim SJ; So SY; Yoon YC; Cho WT; Oh JK
    Injury; 2015 Dec; 46(12):2507-11. PubMed ID: 26358514
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.