These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
248 related articles for article (PubMed ID: 33532920)
21. Prediction of Clinical Outcome After Acute Ischemic Stroke: The Value of Repeated Noncontrast Computed Tomography, Computed Tomographic Angiography, and Computed Tomographic Perfusion. Dankbaar JW; Horsch AD; van den Hoven AF; Kappelle LJ; van der Schaaf IC; van Seeters T; Velthuis BK; Stroke; 2017 Sep; 48(9):2593-2596. PubMed ID: 28716981 [TBL] [Abstract][Full Text] [Related]
22. Standardizing the estimation of ischemic regions can harmonize CT perfusion stroke imaging. Peerlings D; Bennink E; Dankbaar JW; Velthuis BK; Emmer BJ; Hoving JW; Majoie CBLM; Marquering HA; van Voorst H; de Jong HWAM; Eur Radiol; 2024 Feb; 34(2):797-807. PubMed ID: 37572189 [TBL] [Abstract][Full Text] [Related]
23. Defining Ischemic Core in Acute Ischemic Stroke Using CT Perfusion: A Multiparametric Bayesian-Based Model. Nael K; Tadayon E; Wheelwright D; Metry A; Fifi JT; Tuhrim S; De Leacy RA; Doshi AH; Chang HL; Mocco J AJNR Am J Neuroradiol; 2019 Sep; 40(9):1491-1497. PubMed ID: 31413007 [TBL] [Abstract][Full Text] [Related]
24. The evolution of the cerebral blood volume abnormality in patients with ischemic stroke: a CT perfusion study. d'Esterre CD; Aviv RI; Lee TY Acta Radiol; 2012 May; 53(4):461-7. PubMed ID: 22434930 [TBL] [Abstract][Full Text] [Related]
25. Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke. Campbell BC; Christensen S; Levi CR; Desmond PM; Donnan GA; Davis SM; Parsons MW Stroke; 2012 Oct; 43(10):2648-53. PubMed ID: 22858726 [TBL] [Abstract][Full Text] [Related]
27. Performance and Predictive Value of a User-Independent Platform for CT Perfusion Analysis: Threshold-Derived Automated Systems Outperform Examiner-Driven Approaches in Outcome Prediction of Acute Ischemic Stroke. Dehkharghani S; Bammer R; Straka M; Albin LS; Kass-Hout O; Allen JW; Rangaraju S; Qiu D; Winningham MJ; Nahab F AJNR Am J Neuroradiol; 2015 Aug; 36(8):1419-25. PubMed ID: 25999410 [TBL] [Abstract][Full Text] [Related]
28. Dose reduction in perfusion CT in stroke patients by lowering scan frequency does not affect automatically calculated infarct core volumes. Karwacki GM; Vögele S; Blackham KA J Neuroradiol; 2019 Nov; 46(6):351-358. PubMed ID: 31034899 [TBL] [Abstract][Full Text] [Related]
29. Outcome After Acute Ischemic Stroke Treatment During Covid-19 Outbreak in South-East Tuscany. Acampa M; Peresso V; Lazzerini PE; Domenichelli C; Guideri F; Tassi R; Dami S; Marconi R; Iannelli G; Linoli G; Peppoloni G; Nocentini S; Gallerini S; Cartocci A; Bracco S; Martini G Cardiovasc Hematol Disord Drug Targets; 2021; 21(3):179-184. PubMed ID: 34579640 [TBL] [Abstract][Full Text] [Related]
30. Two-way comparison of brain perfusion image processing software for patients with acute ischemic strokes in real-world. Cai H; Fan S; Bian Y; Yang Q; Long Z; Chen L; Tang W; Zhang N; Zhen Y; Li Z Neuroradiology; 2022 Jan; 64(1):161-169. PubMed ID: 34331546 [TBL] [Abstract][Full Text] [Related]
31. ISP-Net: Fusing features to predict ischemic stroke infarct core on CT perfusion maps. Zhu H; Chen Y; Tang T; Ma G; Zhou J; Zhang J; Lu S; Wu F; Luo L; Liu S; Ju S; Shi H Comput Methods Programs Biomed; 2022 Mar; 215():106630. PubMed ID: 35063712 [TBL] [Abstract][Full Text] [Related]
32. Comparison of two automated CT perfusion software packages in patients with ischemic stroke presenting within 24 h of onset. Kim N; Ha SY; Park GH; Park JH; Kim D; Sunwoo L; Kye MS; Baik SH; Jung C; Ryu WS; Kim BJ Front Neurosci; 2024; 18():1398889. PubMed ID: 38868398 [TBL] [Abstract][Full Text] [Related]
33. ASPECTS is a predictor of favorable CT perfusion in acute ischemic stroke. Yaghi S; Bianchi N; Amole A; Hinduja A J Neuroradiol; 2014 Jul; 41(3):184-7. PubMed ID: 24156874 [TBL] [Abstract][Full Text] [Related]
34. Comparison of CT angiography collaterals for predicting target perfusion profile and clinical outcome in patients with acute ischemic stroke. Lu SS; Zhang X; Xu XQ; Cao YZ; Zhao LB; Liu QH; Wu FY; Liu S; Shi HB Eur Radiol; 2019 Sep; 29(9):4922-4929. PubMed ID: 30762114 [TBL] [Abstract][Full Text] [Related]
36. Identification of infarct core and penumbra in acute stroke using CT perfusion source images. Wang XC; Gao PY; Xue J; Liu GR; Ma L AJNR Am J Neuroradiol; 2010 Jan; 31(1):34-9. PubMed ID: 19875465 [TBL] [Abstract][Full Text] [Related]
37. Comparison of automated infarct core volume measures between non-contrast computed tomography and perfusion imaging in acute stroke code patients evaluated for potential endovascular treatment. Suomalainen OP; Elseoud AA; Martinez-Majander N; Tiainen M; Forss N; Curtze S J Neurol Sci; 2021 Jul; 426():117483. PubMed ID: 33989851 [TBL] [Abstract][Full Text] [Related]
38. Clinical use of computed tomographic perfusion for the diagnosis and prediction of lesion growth in acute ischemic stroke. Huisa BN; Neil WP; Schrader R; Maya M; Pereira B; Bruce NT; Lyden PD J Stroke Cerebrovasc Dis; 2014 Jan; 23(1):114-22. PubMed ID: 23253533 [TBL] [Abstract][Full Text] [Related]
39. Time-Dependent Computed Tomographic Perfusion Thresholds for Patients With Acute Ischemic Stroke. d'Esterre CD; Boesen ME; Ahn SH; Pordeli P; Najm M; Minhas P; Davari P; Fainardi E; Rubiera M; Khaw AV; Zini A; Frayne R; Hill MD; Demchuk AM; Sajobi TT; Forkert ND; Goyal M; Lee TY; Menon BK Stroke; 2015 Dec; 46(12):3390-7. PubMed ID: 26514186 [TBL] [Abstract][Full Text] [Related]
40. Correction for Delay and Dispersion Results in More Accurate Cerebral Blood Flow Ischemic Core Measurement in Acute Stroke. Lin L; Bivard A; Kleinig T; Spratt NJ; Levi CR; Yang Q; Parsons MW Stroke; 2018 Apr; 49(4):924-930. PubMed ID: 29500248 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]