These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 33535145)

  • 1. Computational simulations of hybrid mediated nano- hemodynamics (Ag-Au/Blood) through an irregular symmetric stenosis.
    Tripathi J; Vasu B; Bég OA
    Comput Biol Med; 2021 Mar; 130():104213. PubMed ID: 33535145
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Unsteady hybrid nanoparticle-mediated magneto-hemodynamics and heat transfer through an overlapped stenotic artery: Biomedical drug delivery simulation.
    Tripathi J; Vasu B; Bég OA; Gorla RSR
    Proc Inst Mech Eng H; 2021 Oct; 235(10):1175-1196. PubMed ID: 34154464
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computational simulation of rheological blood flow containing hybrid nanoparticles in an inclined catheterized artery with stenotic, aneurysmal and slip effects.
    Tripathi J; Vasu B; Bég OA; Gorla RSR; Kameswaran PK
    Comput Biol Med; 2021 Dec; 139():105009. PubMed ID: 34775156
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computational fluid dynamic simulation of two-fluid non-Newtonian nanohemodynamics through a diseased artery with a stenosis and aneurysm.
    Dubey A; Vasu B; Anwar Bég O; Gorla RSR; Kadir A
    Comput Methods Biomech Biomed Engin; 2020 Jun; 23(8):345-371. PubMed ID: 32098508
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Numerical simulation of the transport of nanoparticles as drug carriers in hydromagnetic blood flow through a diseased artery with vessel wall permeability and rheological effects.
    Tripathi J; Vasu B; Bég OA; Mounika BR; Gorla RSR
    Microvasc Res; 2022 Jan; 139():104241. PubMed ID: 34508788
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Significance of Hall currents on hybrid nano-blood flow through an inclined artery having mild stenosis: Homotopy perturbation approach.
    Das S; Pal TK; Jana RN; Giri B
    Microvasc Res; 2021 Sep; 137():104192. PubMed ID: 34081994
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation.
    Vasu B; Dubey A; Bég OA; Gorla RSR
    Comput Biol Med; 2020 Nov; 126():104025. PubMed ID: 33074112
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Numerical simulation of the transport of nanoparticles as drug carriers in hydromagnetic blood flow through a diseased artery with vessel wall permeability and rheological effects.
    Tripathi J; Vasu B; Bég OA; Mounika BR; Gorla RSR
    Microvasc Res; 2022 Jul; 142():104375. PubMed ID: 35577615
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element computation of magneto-hemodynamic flow and heat transfer in a bifurcated artery with saccular aneurysm using the Carreau-Yasuda biorheological model.
    Dubey A; B V; Bég OA; Gorla RSR
    Microvasc Res; 2021 Nov; 138():104221. PubMed ID: 34271062
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coronary arteries hemodynamics: effect of arterial geometry on hemodynamic parameters causing atherosclerosis.
    Wong KKL; Wu J; Liu G; Huang W; Ghista DN
    Med Biol Eng Comput; 2020 Aug; 58(8):1831-1843. PubMed ID: 32519006
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of an Experimental and Digital Cardiovascular Arterial Model for Transient Hemodynamic and Postural Change Studies: "A Preliminary Framework Analysis".
    Hewlin RL; Kizito JP
    Cardiovasc Eng Technol; 2018 Mar; 9(1):1-31. PubMed ID: 29124548
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cu and Cu-SWCNT Nanoparticles' Suspension in Pulsatile Casson Fluid Flow via Darcy-Forchheimer Porous Channel with Compliant Walls: A Prospective Model for Blood Flow in Stenosed Arteries.
    Ali A; Bukhari Z; Umar M; Ismail MA; Abbas Z
    Int J Mol Sci; 2021 Jun; 22(12):. PubMed ID: 34204328
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hybrid mediated blood flow investigation for atherosclerotic bifurcated lesions with slip, convective and compliant wall impacts.
    Shahzadi I; Kousar N
    Comput Methods Programs Biomed; 2019 Oct; 179():104980. PubMed ID: 31443870
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Numerical simulation of unsteady micropolar hemodynamics in a tapered catheterized artery with a combination of stenosis and aneurysm.
    Zaman A; Ali N; Anwar Bég O
    Med Biol Eng Comput; 2016 Sep; 54(9):1423-36. PubMed ID: 26541601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electroosmotic and Gyrotactic Microorganisms Effects on MHD Al
    Khanduri U; Sharma BK; Almohsen B; Bhatti MM
    Front Biosci (Landmark Ed); 2024 Mar; 29(3):110. PubMed ID: 38538264
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulsatile flow of non-Newtonian blood fluid inside stenosed arteries: Investigating the effects of viscoelastic and elastic walls, arteriosclerosis, and polycythemia diseases.
    Nejad AA; Talebi Z; Cheraghali D; Shahbani-Zahiri A; Norouzi M
    Comput Methods Programs Biomed; 2018 Feb; 154():109-122. PubMed ID: 29249336
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Entropy optimization and response surface methodology of blood hybrid nanofluid flow through composite stenosis artery with magnetized nanoparticles (Au-Ta) for drug delivery application.
    Algehyne EA; Ahammad NA; Elnair ME; Zidan M; Alhusayni YY; El-Bashir BO; Saeed A; Alshomrani AS; Alzahrani F
    Sci Rep; 2023 Jun; 13(1):9856. PubMed ID: 37330555
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computational study of effect of hybrid nanoparticles on hemodynamics and thermal transfer in ruptured arteries with pathological dilation.
    Hussain A; Riaz MB; Dar MNR; Kanwal R; Sarwar L; Jhangeer A
    Sci Rep; 2024 Jun; 14(1):13400. PubMed ID: 38862596
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modelling and simulation of fluid flow through stenosis and aneurysm blood vessel: a computational hemodynamic analysis.
    Ramana Reddy JV; Ha H; Sundar S
    Comput Methods Biomech Biomed Engin; 2023 Sep; 26(10):1160-1182. PubMed ID: 35993592
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of Metallic Nanoparticles on Blood Flow Through Arteries Having Both Stenosis and Aneurysm.
    Nadeem S; Ijaz S
    IEEE Trans Nanobioscience; 2015 Sep; 14(6):668-79. PubMed ID: 26208361
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.