These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 3353951)

  • 1. [Late femur shaft fractures around an implanted hip prosthesis].
    Skogesal OG; Bjørnland G
    Tidsskr Nor Laegeforen; 1988 Feb; 108(6):491-2. PubMed ID: 3353951
    [No Abstract]   [Full Text] [Related]  

  • 2. Late fracture of the femur following perforation during hip arthroplasty. A report of 2 cases.
    Fredin H
    Acta Orthop Scand; 1988 Jun; 59(3):331-2. PubMed ID: 3381669
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Femoral shaft perforation: a complication of total hip reconstruction.
    Talab YA; States JD; Evarts CM
    Clin Orthop Relat Res; 1979 Jun; (141):158-65. PubMed ID: 477097
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Fracture of the femur associated with ipsilateral hip replacement. A complication of hip replacement].
    Rasmussen AK; Naver L
    Ugeskr Laeger; 1984 Dec; 146(49):3839-41. PubMed ID: 6516021
    [No Abstract]   [Full Text] [Related]  

  • 5. [Fractures of the femur in patients with arthroprosthesis of the hip].
    Tamburrelli F; Bartolini F
    Arch Putti Chir Organi Mov; 1984; 34():233-42. PubMed ID: 6544080
    [No Abstract]   [Full Text] [Related]  

  • 6. [Postoperative fractures of the femur with hip prosthesis].
    Toni A; Giunti A; Graci A; Vicenzi G; Montagnani A; Vadalà E; Baldini N
    Chir Organi Mov; 1985; 70(1):53-65. PubMed ID: 4064804
    [No Abstract]   [Full Text] [Related]  

  • 7. [Fracture of the femur in patients with hip prostheses. Apropos of 36 cases].
    Jarde O; Obry C; Plaquet JL; Vives P
    Acta Orthop Belg; 1988; 54(4):429-33. PubMed ID: 3250197
    [No Abstract]   [Full Text] [Related]  

  • 8. [Intraoperative fracture of the femur during non-cemented arthroprosthesis of the hip].
    Baldini N; Toni A; Greggi T; Sudanese A; Giunti A
    Chir Organi Mov; 1986; 71(4):337-41. PubMed ID: 3595271
    [No Abstract]   [Full Text] [Related]  

  • 9. [Femoral fracture in patients with hip prosthesis].
    Servoll E; Hasselgård T; Kleven H; Odegård O
    Tidsskr Nor Laegeforen; 1986 Jan; 106(2):117-8. PubMed ID: 3952700
    [No Abstract]   [Full Text] [Related]  

  • 10. Femoral shaft fractures after cemented total hip arthroplasty.
    Garcia-Cimbrelo E; Munuera L; Gil-Garay E
    Int Orthop; 1992; 16(1):97-100. PubMed ID: 1572780
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Endosteal reaction in the region surrounding the stem of a cement-free prosthesis. An early radiological sign of imminent fracture of the femoral shaft?].
    Wedemeyer C; Russe K; von Knoch M; Saxler G
    Unfallchirurg; 2007 Jan; 110(1):75-7. PubMed ID: 17058057
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shaft fissures due to implantation of cementless total endoprostheses of the hip joint. An experimental study.
    Jantsch S; Leixnering M; Schwägerl W; Hackl H
    Arch Orthop Trauma Surg (1978); 1988; 107(4):236-41. PubMed ID: 3408320
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous fracture of the femur and the femoral stem following total hip replacement. A case report.
    Tanchev PI; Dikov DM; Novkov HV
    Int Orthop; 1996; 20(3):182-4. PubMed ID: 8832323
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Femoral fractures following total hip prosthesis].
    Zuber K; Koch P; Lustenberger A; Ganz R
    Unfallchirurg; 1990 Oct; 93(10):467-72. PubMed ID: 2247780
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fracture of the shaft of the femur at the apex of the stem of a femoral prosthesis.
    Agrifoglio E
    Ital J Orthop Traumatol; 1983 Jun; 9(2):219-23. PubMed ID: 6654657
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Use of Partridge fixation for femoral fracture after total hip replacement].
    Anyzewski P; Benke G; Krawczyk J
    Chir Narzadow Ruchu Ortop Pol; 1993; 58(5):399-402. PubMed ID: 7671722
    [No Abstract]   [Full Text] [Related]  

  • 17. Femoral fractures associated with Moore's prosthesis.
    Harrington IJ; Tountas AA; Cameron HU
    Injury; 1979 Aug; 11(1):23-32. PubMed ID: 521135
    [No Abstract]   [Full Text] [Related]  

  • 18. Intraoperative fractures of the femoral diaphysis in hip arthroprosthesis surgery.
    Federici A; Carbone M; Sanguineti F
    Ital J Orthop Traumatol; 1988 Sep; 14(3):311-21. PubMed ID: 3246490
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Controlled perforation. A safe method of cement removal from the femoral canal.
    Sydney SV; Mallory TH
    Clin Orthop Relat Res; 1990 Apr; (253):168-72. PubMed ID: 2317970
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoral fracture during non-cemented total hip arthroplasty.
    Schwartz JT; Mayer JG; Engh CA
    J Bone Joint Surg Am; 1989 Sep; 71(8):1135-42. PubMed ID: 2777839
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.