214 related articles for article (PubMed ID: 33540103)
1. The Development of Novel 2-in-1 Patient-Specific, 3D-Printed Laminectomy Guides with Integrated Pedicle Screw Drill Guides.
Kanawati A; Rodrigues Fernandes RJ; Gee A; Urquhart J; Siddiqi F; Gurr K; Bailey CS; Rasoulinejad P
World Neurosurg; 2021 May; 149():e821-e827. PubMed ID: 33540103
[TBL] [Abstract][Full Text] [Related]
2. Generating patient-matched 3D-printed pedicle screw and laminectomy drill guides from Cone Beam CT images: Studies in ovine and porcine cadavers.
Kanawati A; Constantinidis A; Williams Z; O'Brien R; Reynolds T
Med Phys; 2022 Jul; 49(7):4642-4652. PubMed ID: 35445429
[TBL] [Abstract][Full Text] [Related]
3. A Comparison of Drill Guiding and Screw Guiding 3D-Printing Techniques for Intra- and Extrapedicular Screw Insertion.
Pijpker PAJ; Kuijlen JMA; Kraeima J; Groen RJM; Faber C
Spine (Phila Pa 1976); 2022 May; 47(10):E434-E441. PubMed ID: 34132234
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories.
Pijpker PAJ; Kraeima J; Witjes MJH; Oterdoom DLM; Vergeer RA; Coppes MH; Groen RJM; Kuijlen JMA
Spine (Phila Pa 1976); 2021 Feb; 46(3):160-168. PubMed ID: 33093310
[TBL] [Abstract][Full Text] [Related]
5. Cortical pedicle screw placement in lumbar spinal surgery with a patient-matched targeting guide: A cadaveric study.
Kaito T; Matsukawa K; Abe Y; Fiechter M; Zhu X; Fantigrossi A
J Orthop Sci; 2018 Nov; 23(6):865-869. PubMed ID: 30042005
[TBL] [Abstract][Full Text] [Related]
6. Application of a novel 3D drill template for cervical pedicle screw tunnel design: a cadaveric study.
Yu Z; Zhang G; Chen X; Chen X; Wu C; Lin Y; Huang W; Lin H
Eur Spine J; 2017 Sep; 26(9):2348-2356. PubMed ID: 28601990
[TBL] [Abstract][Full Text] [Related]
7. Pedicle screw insertion with patient-specific 3D-printed guides based on low-dose CT scan is more accurate than free-hand technique in spine deformity patients: a prospective, randomized clinical trial.
Cecchinato R; Berjano P; Zerbi A; Damilano M; Redaelli A; Lamartina C
Eur Spine J; 2019 Jul; 28(7):1712-1723. PubMed ID: 31006069
[TBL] [Abstract][Full Text] [Related]
8. A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study.
Lu S; Xu YQ; Zhang YZ; Li YB; Xie L; Shi JH; Guo H; Chen GP; Chen YB
Int J Med Robot; 2009 Jun; 5(2):184-91. PubMed ID: 19280584
[TBL] [Abstract][Full Text] [Related]
9. Accuracy Assessment of Pedicle and Lateral Mass Screw Insertion Assisted by Customized 3D-Printed Drill Guides: A Human Cadaver Study.
Pijpker PAJ; Kraeima J; Witjes MJH; Oterdoom DLM; Coppes MH; Groen RJM; Kuijlen JMA
Oper Neurosurg (Hagerstown); 2019 Jan; 16(1):94-102. PubMed ID: 29660055
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of Patient-Specific Drill Guide Template for Bilateral C1-C2 Laminar Screw Placement: A Cadaveric Study.
Fernandes RJR; Gee A; Schneider N; Kanawati AJ; Bailey CS; Rasoulinejad P
World Neurosurg; 2022 Jun; 162():e225-e234. PubMed ID: 35259502
[TBL] [Abstract][Full Text] [Related]
11. Cortical Bone Trajectory Screw Placement Accuracy with a Patient-Matched 3-Dimensional Printed Guide in Lumbar Spinal Surgery: A Clinical Study.
Marengo N; Matsukawa K; Monticelli M; Ajello M; Pacca P; Cofano F; Penner F; Zenga F; Ducati A; Garbossa D
World Neurosurg; 2019 Oct; 130():e98-e104. PubMed ID: 31307931
[TBL] [Abstract][Full Text] [Related]
12. Influence of a customized three-dimensionally printed drill guide on the accuracy of pedicle screw placement in lumbosacral vertebrae: An ex vivo study.
Beer P; Park BH; Steffen F; Smolders DLA; Pozzi A; Knell SC
Vet Surg; 2020 Jul; 49(5):977-988. PubMed ID: 32255212
[TBL] [Abstract][Full Text] [Related]
13. Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three-dimensionally printed patient-specific drill guides.
Elford JH; Oxley B; Behr S
Vet Surg; 2020 Feb; 49(2):347-353. PubMed ID: 31617955
[TBL] [Abstract][Full Text] [Related]
14. Use of a life-size three-dimensional-printed spine model for pedicle screw instrumentation training.
Park HJ; Wang C; Choi KH; Kim HN
J Orthop Surg Res; 2018 Apr; 13(1):86. PubMed ID: 29661210
[TBL] [Abstract][Full Text] [Related]
15. Accuracy assessment of pedicle screw insertion with patient specific 3D‑printed guides through superimpose CT-analysis in thoracolumbar spinal deformity surgery.
Cool J; van Schuppen J; de Boer MA; van Royen BJ
Eur Spine J; 2021 Nov; 30(11):3216-3224. PubMed ID: 34355276
[TBL] [Abstract][Full Text] [Related]
16. Double-trajectory lumbar screw placement guided by a set of 3D-printed surgical guide templates: a cadaver study.
Zhao Y; Liang J; Luo H; Xu Y; Lu S
BMC Musculoskelet Disord; 2021 Mar; 22(1):296. PubMed ID: 33752641
[TBL] [Abstract][Full Text] [Related]
17. Optimizing Lumbar Pedicle Screw Trajectory Utilizing a 3D-Printed Drill Guide to Ensure Placement of Pedicle Screws Into Higher Density Bone May Improve Pedicle Screw Pullout Resistance.
Zhao X; Zhao J; Sun XJ; Zhou XH; Zhang K; Xie YZ
World Neurosurg; 2022 Feb; 158():e459-e464. PubMed ID: 34763101
[TBL] [Abstract][Full Text] [Related]
18. Outcome and safety analysis of 3D-printed patient-specific pedicle screw jigs for complex spinal deformities: a comparative study.
Garg B; Gupta M; Singh M; Kalyanasundaram D
Spine J; 2019 Jan; 19(1):56-64. PubMed ID: 29730456
[TBL] [Abstract][Full Text] [Related]
19. Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system.
Kaneyama S; Sugawara T; Sumi M
Spine (Phila Pa 1976); 2015 Mar; 40(6):E341-8. PubMed ID: 25584951
[TBL] [Abstract][Full Text] [Related]
20. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.
Malham GM; Parker RM
J Neurosurg Spine; 2018 Apr; 28(4):357-363. PubMed ID: 29372857
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]