These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 33540235)

  • 1. Experimental identification of high order Lamb waves and estimation of the mechanical properties of a dry human skull.
    Mazzotti M; Sugino C; Kohtanen E; Erturk A; Ruzzene M
    Ultrasonics; 2021 May; 113():106343. PubMed ID: 33540235
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental and Computational Investigation of Guided Waves in a Human Skull.
    Sugino C; Ruzzene M; Erturk A
    Ultrasound Med Biol; 2021 Mar; 47(3):787-798. PubMed ID: 33358510
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiation Characteristics of Cranial Leaky Lamb Waves.
    Mazzotti M; Kohtanen E; Erturk A; Ruzzene M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Jun; 68(6):2129-2140. PubMed ID: 33544671
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Selective Generation of Lamb Wave Modes in a Finite-Width Plate by Angle-Beam Excitation Method.
    Park SJ; Joo YS; Kim HW; Kim SK
    Sensors (Basel); 2020 Jul; 20(14):. PubMed ID: 32664426
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lamb wave dispersion ultrasound vibrometry (LDUV) method for quantifying mechanical properties of viscoelastic solids.
    Nenadic IZ; Urban MW; Mitchell SA; Greenleaf JF
    Phys Med Biol; 2011 Apr; 56(7):2245-64. PubMed ID: 21403186
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Vibration-based elastic parameter identification of the diploë and cortical tables in dry cranial bones.
    Kohtanen E; Mazzotti M; Ruzzene M; Erturk A
    J Mech Behav Biomed Mater; 2021 Nov; 123():104747. PubMed ID: 34399287
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Excitation of ultrasonic Lamb waves using a phased array system with two array probes: phantom and in vitro bone studies.
    Nguyen KC; Le LH; Tran TN; Sacchi MD; Lou EH
    Ultrasonics; 2014 Jul; 54(5):1178-85. PubMed ID: 24074751
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multi-frequency characterization of the speed of sound and attenuation coefficient for longitudinal transmission of freshly excised human skulls.
    Pichardo S; Sin VW; Hynynen K
    Phys Med Biol; 2011 Jan; 56(1):219-50. PubMed ID: 21149950
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On Lamb and Rayleigh wave convergence in viscoelastic tissues.
    Nenadic IZ; Urban MW; Aristizabal S; Mitchell SA; Humphrey TC; Greenleaf JF
    Phys Med Biol; 2011 Oct; 56(20):6723-38. PubMed ID: 21970846
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A combined finite element and modal decomposition method to study the interaction of Lamb modes with micro-defects.
    Terrien N; Osmont D; Royer D; Lepoutre F; Déom A
    Ultrasonics; 2007 Mar; 46(1):74-88. PubMed ID: 17208265
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Model-based autonomous plate defects visualization method for quantitative wall-thinning estimation.
    Kang T; Han SJ; Moon S; Han S; Kim KM
    Ultrasonics; 2021 Dec; 117():106541. PubMed ID: 34375843
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Active fiber composites for the generation of Lamb waves.
    Birchmeier M; Gsell D; Juon M; Brunner AJ; Paradies R; Dual J
    Ultrasonics; 2009 Jan; 49(1):73-82. PubMed ID: 18621408
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simulation-Based Characterization of Mechanical Parameters and Thickness of Homogeneous Plates Using Guided Waves.
    Ponschab M; Kiefer DA; Rupitsch SJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2019 Dec; 66(12):1898-1905. PubMed ID: 31398117
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On the Directivity of Lamb Waves Generated by Wedge PZT Actuator in Thin CFRP Panel.
    Shevtsov S; Chebanenko V; Shevtsova M; Chang SH; Kirillova E; Rozhkov E
    Materials (Basel); 2020 Feb; 13(4):. PubMed ID: 32085550
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transient analysis of leaky Lamb waves with a semi-analytical finite element method.
    Inoue D; Hayashi T
    Ultrasonics; 2015 Sep; 62():80-8. PubMed ID: 26048173
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Peri-Elastodynamic Simulations of Guided Ultrasonic Waves in Plate-Like Structure with Surface Mounted PZT.
    Patra S; Ahmed H; Banerjee S
    Sensors (Basel); 2018 Jan; 18(1):. PubMed ID: 29346295
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Laser-ultrasonic generation of Lamb waves in the reaction force range.
    Shi Y; Wooh SC; Orwat M
    Ultrasonics; 2003 Nov; 41(8):623-33. PubMed ID: 14585474
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effects of air gap reflections during air-coupled leaky Lamb wave inspection of thin plates.
    Fan Z; Jiang W; Cai M; Wright WM
    Ultrasonics; 2016 Feb; 65():282-95. PubMed ID: 26464105
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The simulation of Lamb waves in a cracked plate using the scaled boundary finite element method.
    Gravenkamp H; Prager J; Saputra AA; Song C
    J Acoust Soc Am; 2012 Sep; 132(3):1358-67. PubMed ID: 22978864
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calculation of leaky Lamb waves with a semi-analytical finite element method.
    Hayashi T; Inoue D
    Ultrasonics; 2014 Aug; 54(6):1460-9. PubMed ID: 24838216
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.