BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 33541095)

  • 1. Bioprosthetic Valve Thrombosis Associated With COVID-19 Infection.
    Alexander SA; Fergus IV; Lerakis S
    Circ Cardiovasc Imaging; 2021 May; 14(5):e012118. PubMed ID: 33541095
    [No Abstract]   [Full Text] [Related]  

  • 2. Bioprosthetic Valve Thrombosis and Obstruction Secondary to COVID-19.
    Llopis Gisbert G; Vidal Urrutia V; Moruno Benita MA; Payá Chaume A; Berenguer Jofresa A; Cubillos Arango AM; Pérez Boscá JL; Payá Serrano R
    Can J Cardiol; 2021 Jun; 37(6):938.e3-938.e6. PubMed ID: 33485934
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Case of Very Late (3 Years) Transcatheter Heart Valve Thrombosis.
    Regazzoli D; Ancona MB; Mangieri A; Agricola E; Spagnolo P; Mussardo M; Colombo A; Latib A
    JACC Cardiovasc Interv; 2016 Apr; 9(8):e83-e84. PubMed ID: 27101920
    [No Abstract]   [Full Text] [Related]  

  • 4. Cardiac CT provides uniquely accurate and comprehensive assessment of bioprosthetic aortic valve stenosis.
    Khan JN; Devlin B; Verma S; Ruzsics B
    BMJ Case Rep; 2018 May; 2018():. PubMed ID: 29728437
    [No Abstract]   [Full Text] [Related]  

  • 5. Detection of thrombotic cuspal obstruction of an aortic bioprosthesis with transesophageal echocardiography.
    Capodilupo RC; Plehn JF
    J Am Soc Echocardiogr; 1997; 10(6):685-8. PubMed ID: 9282360
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of Computed Tomography to Distinguish Thrombus from Pannus on a Bioprosthetic Aortic Valve.
    Kealhofer JV; Markowitz JS; Nijjar PS
    Tex Heart Inst J; 2019 Jun; 46(3):219-221. PubMed ID: 31708708
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Very Early Thrombosis of Sapien 3 Valve.
    Neylon A; Degrell P; Troussier X; Hovasse T; Cormier B; Bouvier E; Unterseeh T
    JACC Cardiovasc Interv; 2016 Feb; 9(4):e35-e36. PubMed ID: 26777330
    [No Abstract]   [Full Text] [Related]  

  • 8. Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement: Incidence, Characteristics, and Treatment Outcomes.
    Jose J; Sulimov DS; El-Mawardy M; Sato T; Allali A; Holy EW; Becker B; Landt M; Kebernik J; Schwarz B; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2017 Apr; 10(7):686-697. PubMed ID: 28385406
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bioprosthetic mitral valve thrombosis complicating antiphospholipid antibody syndrome, successfully treated with thrombolysis.
    Chamsi-Pasha MA; Alyousef T; Sayyed S
    Echocardiography; 2014 Oct; 31(9):E278-81. PubMed ID: 25047224
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bioprosthesis leaflet thrombosis following self-expanding valve-in-valve transcatheter aortic valve replacement in patient taking factor Xa inhibitor and warfarin: A case report.
    Buchanan KD; Alraies MC; Weissman G; Ben-Dor I; Satler LF; Waksman R
    Cardiovasc Revasc Med; 2018 Jan; 19(1 Pt A):29-32. PubMed ID: 29066342
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bioprosthetic mitral valve thrombosis: clinical profile, transesophageal echocardiographic features, and follow-up after anticoagulant therapy.
    Oliver JM; Gallego P; Gonzalez A; Dominguez FJ; Gamallo C; Mesa JM
    J Am Soc Echocardiogr; 1996; 9(5):691-9. PubMed ID: 8887873
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Early bioprosthetic mitral valve thrombosis].
    Tkaczyszyn M; Olbrycht T; Kustrzycka Kratochwil D; Sokolski M; Sukiennik Kujawa M; Skiba J; Gemel M; Banasiak W; Jankowska EA; Ponikowski P
    Kardiol Pol; 2012; 70(2):165-8. PubMed ID: 22427084
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcatheter valve-in-valve implantation for sutureless bioprosthetic aortic paravalvular leak in the era of COVID-19.
    Arslan Ş; Bayar N; Erkal Z; Köklü E; Çağırcı G
    Anatol J Cardiol; 2021 Mar; 25(3):209-211. PubMed ID: 33690137
    [No Abstract]   [Full Text] [Related]  

  • 14. Severe stenosis of bioprosthetic valve due to late valve thrombosis.
    Hegde S; Rahban Y; Agnihotri A; Maysky M
    J Card Surg; 2020 Nov; 35(11):3150-3152. PubMed ID: 32939834
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bioprosthetic mitral valve thrombosis and subsequent obstruction from non-Hodgkins lymphoma despite anticoagulation.
    Khanji MY; Wheeler R; Nawaytou O; Sheikh AS
    Echocardiography; 2018 Dec; 35(12):2104-2105. PubMed ID: 30318840
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Acute thrombosis of an aortic bioprosthetic valve: transthoracic and transesophageal echocardiographic findings.
    Adamick RD; Gleckel LC; Graver LM
    Am Heart J; 1991 Jul; 122(1 Pt 1):241-2. PubMed ID: 2063748
    [No Abstract]   [Full Text] [Related]  

  • 17. Late thrombotic obstruction of an aortic bioprosthetic valve: successful treatment by oral anticoagulation.
    Juliard JM; Paillole C; Dahan M; Steg PG; Himbert D; Aumont MC
    Clin Cardiol; 1993 Feb; 16(2):152-4. PubMed ID: 8435930
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Obstructive bioprosthetic mitral valve thrombus: management options?
    Alshehri HZ; Ismail M; Ibrahim MF
    Asian Cardiovasc Thorac Ann; 2014 Oct; 22(8):975-8. PubMed ID: 24887839
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Sticky Situation: Aortic Valve Thrombus in Patient with Antiphospholipid Antibody Syndrome and Immune Thrombocytopenia.
    Sudhakar D; Kamran H; Chen N; Mims M; Hamzeh I
    Am J Med; 2020 Aug; 133(8):e393-e395. PubMed ID: 31987800
    [No Abstract]   [Full Text] [Related]  

  • 20. Large Bioprosthetic Aortic Valve Thrombi on DOACs.
    Bamford P; Rogers J; Bassin L; Kull A
    Heart Lung Circ; 2019 Oct; 28(10):e139-e142. PubMed ID: 31076237
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.