These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
216 related articles for article (PubMed ID: 33545112)
1. Interference of anti-streptavidin antibodies: More common than we thought? In relation to six confirmed cases. Ricci V; Esteban MP; Sand G; Menises MM Clin Biochem; 2021 Apr; 90():62-65. PubMed ID: 33545112 [TBL] [Abstract][Full Text] [Related]
4. Interference from anti-streptavidin antibody. Rulander NJ; Cardamone D; Senior M; Snyder PJ; Master SR Arch Pathol Lab Med; 2013 Aug; 137(8):1141-6. PubMed ID: 23899071 [TBL] [Abstract][Full Text] [Related]
5. Interference of anti-streptavidin antibodies in immunoassays: a very rare phenomenon or a more common finding? Verougstraete N; Berth M; Vaneechoutte M; Delanghe J; Callewaert N Clin Chem Lab Med; 2020 Sep; 58(10):1673-1680. PubMed ID: 31782946 [TBL] [Abstract][Full Text] [Related]
6. Mitigation of Biotin Interference in Manual and Automated Immunoassays by Preconjugating Biotinylated Antibodies to the Streptavidin Surface as an Alternative to Biotin Depletion. Nelson HA; La'ulu SL; Lu J; Doyle K J Appl Lab Med; 2022 May; 7(3):762-775. PubMed ID: 35018420 [TBL] [Abstract][Full Text] [Related]
7. Comparative multicentre study of a panel of thyroid tests using different automated immunoassay platforms and specimens at high risk of antibody interference. Martel J; Després N; Ahnadi CE; Lachance JF; Monticello JE; Fink G; Ardemagni A; Banfi G; Tovey J; Dykes P; John R; Jeffery J; Grant AM Clin Chem Lab Med; 2000 Aug; 38(8):785-93. PubMed ID: 11071074 [TBL] [Abstract][Full Text] [Related]
8. Characterisation of an interference affecting the triiodothyronine measurement on two different immunoassays. Courcelles L; Luyten U; Wauthier L; Verbeke N; Burlacu MC; Gruson D Acta Clin Belg; 2023 Oct; 78(5):406-409. PubMed ID: 37042022 [TBL] [Abstract][Full Text] [Related]
9. BIOTIN INTERFERENCE WITH ROUTINE CLINICAL IMMUNOASSAYS: UNDERSTAND THE CAUSES AND MITIGATE THE RISKS. Samarasinghe S; Meah F; Singh V; Basit A; Emanuele N; Emanuele MA; Mazhari A; Holmes EW Endocr Pract; 2017 Aug; 23(8):989-998. PubMed ID: 28534685 [TBL] [Abstract][Full Text] [Related]
10. Biotin Interference in Assays for Thyroid Hormones, Thyrotropin and Thyroglobulin. Ylli D; Soldin SJ; Stolze B; Wei B; Nigussie G; Nguyen H; Mendu DR; Mete M; Wu D; Gomes-Lima CJ; Klubo-Gwiezdzinska J; Burman KD; Wartofsky L Thyroid; 2021 Aug; 31(8):1160-1170. PubMed ID: 34042535 [No Abstract] [Full Text] [Related]
11. Interferences in free thyroxine concentration using the Roche analytical platform: improvement of the third generation? Ruth I; Mathieu E; Burniat A; Fage D; Cotton F; Wolff F Clin Chem Lab Med; 2020 Jan; 58(2):e36-e39. PubMed ID: 31377735 [No Abstract] [Full Text] [Related]
12. Biotin interference: evaluation of a new generation of electrochemiluminescent immunoassays for high-sensitive troponin T and thyroid-stimulating hormone testing. Mzougui S; Favresse J; Soleimani R; Fillée C; Gruson D Clin Chem Lab Med; 2020 Nov; 58(12):2037-2045. PubMed ID: 32324155 [TBL] [Abstract][Full Text] [Related]
14. Mitigating biotin interference in two Roche immunoassays by premixing biotinylated capturing molecules with streptavidin coated beads. Yang J; Wiencek JR Clin Chim Acta; 2020 Jun; 505():130-135. PubMed ID: 32084383 [TBL] [Abstract][Full Text] [Related]
15. Interference by antiruthenium antibodies in the Roche thyroid-stimulating hormone assay. Buijs MM; Gorgels JP; Endert E Ann Clin Biochem; 2011 May; 48(Pt 3):276-81. PubMed ID: 21441394 [TBL] [Abstract][Full Text] [Related]
16. Anti-streptavidin interferences in Roche thyroid immunoassays: a case report. Peltier L; Massart C; Moineau MP; Delhostal A; Roudaut N Clin Chem Lab Med; 2016 Jan; 54(1):e11-4. PubMed ID: 26154194 [No Abstract] [Full Text] [Related]
17. Evaluation of Cobas 8000 Analyzer Series Module e801 Analytical Performance. Lim S; Lee K; Woo HY; Park H; Kwon MJ Ann Clin Lab Sci; 2019 May; 49(3):372-379. PubMed ID: 31308038 [TBL] [Abstract][Full Text] [Related]
18. Heterophilic antibody interference with TSH measurement on different immunoassay platforms. Cheng X; Guo X; Chai X; Hu Y; Lian X; Zhang G Clin Chim Acta; 2021 Jan; 512():63-65. PubMed ID: 33285118 [TBL] [Abstract][Full Text] [Related]
19. Association of Biotin Ingestion With Performance of Hormone and Nonhormone Assays in Healthy Adults. Li D; Radulescu A; Shrestha RT; Root M; Karger AB; Killeen AA; Hodges JS; Fan SL; Ferguson A; Garg U; Sokoll LJ; Burmeister LA JAMA; 2017 Sep; 318(12):1150-1160. PubMed ID: 28973622 [TBL] [Abstract][Full Text] [Related]
20. Assessment of Risk for Interference by Circulating Biotin in Samples Received for High Sensitivity Troponin-T, Thyrotropin, and for Prostate Specific Antigen Testing by Immunoassays. Nguyen KQN; Langevin R; Fankhauser K; Hashim IA Clin Lab; 2020 Jan; 66(1):. PubMed ID: 32013345 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]