BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

289 related articles for article (PubMed ID: 33546770)

  • 1. Effects of SP600125 and hypothermic machine perfusion on livers donated after cardiac death in a pig allograft transplantation model.
    Zhang Y; Pan Q; Cheng Y; Liu Y
    Eur J Med Res; 2021 Feb; 26(1):15. PubMed ID: 33546770
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation Using an Isolated Reperfusion Model for Porcine Liver Donated After Cardiac Death Preserved with Oxygenated Hypothermic Machine Perfusion.
    Yoshikawa R; Matsuno N; Morito N; Gouchi M; Otani M; Takahashi H; Shonaka T; Nishikawa Y; Enosawa S; Hirano T; Furukawa H; Obara H
    Ann Transplant; 2018 Nov; 23():822-827. PubMed ID: 30478252
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of Oxygen During Long-term Hypothermic Machine Perfusion in a Porcine Model of Kidney Donation After Circulatory Death.
    Venema LH; Brat A; Moers C; 't Hart NA; Ploeg RJ; Hannaert P; Minor T; Leuvenink AHGD;
    Transplantation; 2019 Oct; 103(10):2057-2064. PubMed ID: 30951018
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hypothermic machine perfusion attenuates ischemia/reperfusion injury against rat livers donated after cardiac death by activating the Keap1/Nrf2‑ARE signaling pathway.
    Xue S; He W; Zeng X; Tang Z; Feng S; Zhong Z; Xiong Y; Wang Y; Ye Q
    Mol Med Rep; 2018 Jul; 18(1):815-826. PubMed ID: 29845199
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Novel N,N-bis-2-Hydroxyethyl-2-Aminoethanesulfonic Acid-Gluconate-Polyethylene Glycol-Hypothermic Machine Perfusion Solution Improves Static Cold Storage and Reduces Ischemia/Reperfusion Injury in Rat Liver Transplant.
    Carnevale ME; Lausada N; Juan de Paz L; Stringa P; Machuca M; Rumbo M; Guibert EE; Tiribelli C; Gondolesi GE; Rodriguez JV
    Liver Transpl; 2019 Sep; 25(9):1375-1386. PubMed ID: 31121085
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of the Selective NLRP3 Inflammasome Inhibitor mcc950 on Transplantation Outcome in a Pig Liver Transplantation Model With Organs From Donors After Circulatory Death Preserved by Hypothermic Machine Perfusion.
    Yu Y; Cheng Y; Pan Q; Zhang YJ; Jia DG; Liu YF
    Transplantation; 2019 Feb; 103(2):353-362. PubMed ID: 30247318
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An Oxygenated and Transportable Machine Perfusion System Fully Rescues Liver Grafts Exposed to Lethal Ischemic Damage in a Pig Model of DCD Liver Transplantation.
    Compagnon P; Levesque E; Hentati H; Disabato M; Calderaro J; Feray C; Corlu A; Cohen JL; Ben Mosbah I; Azoulay D
    Transplantation; 2017 Jul; 101(7):e205-e213. PubMed ID: 28403128
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hypothermic Machine Perfusion Reduced Inflammatory Reaction by Downregulating the Expression of Matrix Metalloproteinase 9 in a Reperfusion Model of Donation After Cardiac Death.
    Fu Z; Ye Q; Zhang Y; Zhong Z; Xiong Y; Wang Y; Hu L; Wang W; Huang W; Ko DS
    Artif Organs; 2016 Jun; 40(6):E102-11. PubMed ID: 26813475
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of Machine Perfusion on Sinusoid Microcirculation of Liver Graft Donated After Cardiac Death.
    Kanazawa H; Obara H; Yoshikawa R; Meng L; Hirano T; Okada Y; Nishikawa Y; Matsuno N
    J Surg Res; 2020 Jan; 245():410-419. PubMed ID: 31437648
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of human-derived hemoglobin based oxygen vesicles as a machine perfusion solution for liver donation after cardiac death in a pig model.
    Shonaka T; Matsuno N; Obara H; Yoshikawa R; Nishikawa Y; Ishihara Y; Bochimoto H; Gochi M; Otani M; Kanazawa H; Azuma H; Sakai H; Furukawa H
    PLoS One; 2019; 14(12):e0226183. PubMed ID: 31825976
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hypothermic oxygenated machine perfusion in porcine donation after circulatory determination of death liver transplant.
    Fondevila C; Hessheimer AJ; Maathuis MH; Muñoz J; Taurá P; Calatayud D; Leuvenink H; Rimola A; García-Valdecasas JC; Ploeg RJ
    Transplantation; 2012 Jul; 94(1):22-9. PubMed ID: 22691959
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Appropriate timing for hypothermic machine perfusion to preserve livers donated after circulatory death.
    Hu X; Wang W; Zeng C; He W; Zhong Z; Liu Z; Wang Y; Ye Q
    Mol Med Rep; 2020 Sep; 22(3):2003-2011. PubMed ID: 32582977
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Novel oxygenation technique for hypothermic machine perfusion of liver grafts: Validation in porcine Donation after Cardiac Death (DCD) liver model.
    Panayotova GG; Rosado J; Paterno F; Deo D; Dikdan G; McCarty MA; Arrington B; Giudice A; Fano A; Dhaduk N; Lunsford KE; Rao P; Guarrera JV
    Am J Surg; 2020 Nov; 220(5):1270-1277. PubMed ID: 32892979
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hypothermic oxygenated machine perfusion prevents arteriolonecrosis of the peribiliary plexus in pig livers donated after circulatory death.
    Op den Dries S; Sutton ME; Karimian N; de Boer MT; Wiersema-Buist J; Gouw AS; Leuvenink HG; Lisman T; Porte RJ
    PLoS One; 2014; 9(2):e88521. PubMed ID: 24551114
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ischemic postconditioning improves the outcome of organs from donors after cardiac death in a pig liver transplantation model and provides synergistic protection with hypothermic machine perfusion.
    Jia D; Pan Q; Zhang Y; Yu Y; Song Z; Liu YF; Jia Z; Guo S; Cheng Y
    Clin Transplant; 2021 Oct; 35(10):e14417. PubMed ID: 34231926
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rewarming preservation by organ perfusion system for donation after cardiac death liver grafts in pigs.
    Matsuno N; Obara H; Watanabe R; Iwata S; Kono S; Fujiyama M; Hirano T; Kanazawa H; Enosawa S
    Transplant Proc; 2014 May; 46(4):1095-8. PubMed ID: 24815137
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hypothermic machine perfusion of liver grafts for transplantation: technical development in human discard and miniature swine models.
    Guarrera JV; Estevez J; Boykin J; Boyce R; Rashid J; Sun S; Arrington B
    Transplant Proc; 2005; 37(1):323-5. PubMed ID: 15808631
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hypothermic oxygenated perfusion (HOPE) protects from biliary injury in a rodent model of DCD liver transplantation.
    Schlegel A; Graf R; Clavien PA; Dutkowski P
    J Hepatol; 2013 Nov; 59(5):984-91. PubMed ID: 23820408
    [TBL] [Abstract][Full Text] [Related]  

  • 19. One hour hypothermic oxygenated perfusion (HOPE) protects nonviable liver allografts donated after cardiac death.
    de Rougemont O; Breitenstein S; Leskosek B; Weber A; Graf R; Clavien PA; Dutkowski P
    Ann Surg; 2009 Nov; 250(5):674-83. PubMed ID: 19806056
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ex Vivo Reperfusion Model to Evaluate Utility of Machine Preservation for Porcine Liver Donated After Cardiac Death.
    Yoshikawa R; Obara H; Matsuno N; Morito N; Gouchi M; Otani M; Shonaka T; Takahashi H; Enosawa S; Hirano T; Furukawa H
    Transplant Proc; 2018 Nov; 50(9):2826-2829. PubMed ID: 30401405
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.